Particle deposition in a cast of human oral airways

被引:284
作者
Cheng, YS [1 ]
Zhou, Y
Chen, BT
机构
[1] Lovelace Resp Res Inst, Albuquerque, NM 87185 USA
[2] NIOSH, Morgantown, WV 26505 USA
关键词
D O I
10.1080/027868299304165
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Oral and nasal airways are entryways to the respiratory tract. Most people breathe through the nasal airway during rest or light exercise, then switch to oral/nasal breathing during heavy exercise or work. Resistance through the oral airways is much lower than through the nasal airways, so fewer aerosol particles are deposited in the oral airways. Aerosol drugs are usually delivered by inhalation to the lung via the oral route for that reason. Oral deposition data from humans are limited, and those available show great intersubject variability. The purpose of this study was to investigate the effects of particle size and breathing rate on the deposition pattern in a human oral airway cast with a defined geometry. The airway replica included the oral cavity, pharynx, larynx, trachea, and 3 generations of bronchi. The oral portion of the cast was molded from a dental impression of the oral cavity in a human volunteer, while the other airway portions of the cast were made from a cadaver. Nine different sizes of polystyrene latex fluorescent particles in the size range of 0.93-30 mu m were used in the study. Regional deposition was measured at a constant inspiratory flow rate of 15, 30, and 60 L min(-1). Deposition in the oral airway appeared to increase with an increasing flow rate and particle diameter. Deposition at the highest flow rate of 60 L min(-1) was close to 90% for particles > 20 mu m. Particles > about 10 mu m deposited mainly in the oral cavity. Deposition efficiency has been found to be a unique function of the Stokes number, suggesting that impaction is the dominant deposition mechanism. Oral deposition can be approximated by a theoretical deposition model of inertial impaction in a 180 degrees curved tube, assuming perfect mixing in a turbulent flow. Our model suggests that the minimum dimension near the larynx and the average cross-sectional area are important parameters for oral airway deposition; however, additional data from the oral airway replica are needed to ascertain whether these are indeed the critical dimensions. Information from the present study will add to our knowledge of the deposition mechanism, the correlation of particle deposition with airway geometry, and eventually the best way to deliver aerosol drugs.
引用
收藏
页码:286 / 300
页数:15
相关论文
共 28 条
  • [1] DEPOSITION OF INHALED PARTICLES IN THE ORAL AIRWAY DURING ORONASAL BREATHING
    BOWES, SM
    SWIFT, DL
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1989, 11 (02) : 157 - 167
  • [2] EXPERIMENTAL MEASUREMENTS AND EMPIRICAL MODELING OF THE REGIONAL DEPOSITION OF INHALED PARTICLES IN HUMANS
    CHAN, TL
    LIPPMANN, M
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (06): : 399 - 408
  • [3] Evaluation of the TSI small-scale powder disperser
    Chen, BT
    Yeh, HC
    Fan, BJ
    [J]. JOURNAL OF AEROSOL SCIENCE, 1995, 26 (08) : 1303 - 1313
  • [4] Cheng KH, 1997, AM IND HYG ASSOC J, V58, P207, DOI 10.1202/0002-8894(1997)058<0207:AEMFMA>2.0.CO
  • [5] 2
  • [6] Cheng KH, 1997, J BIOMED ENG, V119, P475
  • [7] CHENG YS, 1991, RADIAT PROT DOSIM, V38, P41
  • [8] DEPOSITION OF THORON PROGENY IN HUMAN HEAD AIRWAYS
    CHENG, YS
    SU, YF
    YEH, HC
    SWIFT, DL
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1993, 18 (04) : 359 - 375
  • [9] MOTION OF PARTICLES IN BENDS OF CIRCULAR PIPES
    CHENG, YS
    WANG, CS
    [J]. ATMOSPHERIC ENVIRONMENT, 1981, 15 (03) : 301 - 306
  • [10] DEPOSITION OF ULTRAFINE AEROSOLS IN A HUMAN ORAL CAST
    CHENG, YS
    YAMADA, Y
    YEH, HC
    SWIFT, DL
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1990, 12 (04) : 1075 - 1081