Simulating the straylight effects of cataracts

被引:79
作者
de Wit, GC [1 ]
Franssen, L [1 ]
Coppens, JE [1 ]
van den Berg, TJTP [1 ]
机构
[1] Royal Netherlands Acad Arts & Sci, Netherlands Ophthalm Res Inst, NL-1105 BA Amsterdam, Netherlands
关键词
D O I
10.1016/j.jcrs.2006.01.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the additional straylight falling on the retina (retinal straylight) caused by cataract and find commercially available filters to simulate the cataract straylight effects. SETTING: Research laboratory. METHODS: The retinal straylight addition of cataract was derived from straylight parameter data in the literature. The scattering characteristics of cataract-simulating filters were measured using a scatterometer. RESULTS: The straylight addition due to cataract follows a power law as a function of angle with power of -2.12 and straylight parameter log values of up to 1.6 for relatively mild cataract cases. Of the commercial filters that were tested, the Tiffen Black Pro Mist (BPM) filters resembled the straylight: characteristics of cataracts fairly well. The filters had a limited effect on visual acuity and contrast sensitivity, which was also found for early cataracts. The BPM 2 followed a power law as a function of angle with power of approximately -2.21 and straylight log values of 1.12. CONCLUSIONS: The BPM 2 filter is a good early-cataract-simulating filter. Stacking such filters is a good way to increase the cataract density. A drawback is that the BPM 2 filter has a transmission of 66% so stacking filters reduces the overall transmission significantly.
引用
收藏
页码:294 / 300
页数:7
相关论文
共 31 条
[1]   Observations on the optical effects of a cataract [J].
Campbell, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (07) :995-1003
[2]   CONTRAST SENSITIVITY AND VISUAL-ACUITY IN PATIENTS WITH EARLY CATARACTS [J].
CHYLACK, LT ;
JAKUBICZ, G ;
ROSNER, B ;
KHU, P ;
LIBMAN, J ;
WOLFE, JK ;
PADHYE, N ;
FRIEND, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (03) :399-404
[3]   Contrast of displays on the retina [J].
de Wit, GC .
JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2005, 13 (02) :177-178
[4]   Stray light of spectacle lenses compared with stray light in the eye [J].
De Wit, GC ;
Coppens, JE .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (05) :395-400
[5]  
DEWAARD PWT, 1992, INVEST OPHTH VIS SCI, V33, P618
[6]  
ELLIOTT DB, 1993, INVEST OPHTH VIS SCI, V34, P108
[7]   Visual acuity versus letter contrast sensitivity in early cataract [J].
Elliott, DB ;
Situ, P .
VISION RESEARCH, 1998, 38 (13) :2047-2052
[8]   Effect of a cataract simulation on clinical and real world vision [J].
Elliott, DB ;
Bullimore, MA ;
Patla, AE ;
Whitaker, D .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (09) :799-804
[9]   CONTRAST SENSITIVITY AND GLARE SENSITIVITY CHANGES WITH 3 TYPES OF CATARACT MORPHOLOGY - ARE THESE TECHNIQUES NECESSARY IN A CLINICAL-EVALUATION OF CATARACT [J].
ELLIOTT, DB ;
GILCHRIST, J ;
WHITAKER, D .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1989, 9 (01) :25-30
[10]   HYPERACUITY PERIMETRY - ASSESSMENT OF MACULAR FUNCTION THROUGH OCULAR OPACITIES [J].
ENOCH, JM ;
WILLIAMS, RA ;
ESSOCK, EA ;
BARRICKS, M .
ARCHIVES OF OPHTHALMOLOGY, 1984, 102 (08) :1164-1168