Patient-specific finite element analysis of frictional behavior in different esophageal regions during endoscopy

被引:2
作者
Lin, Chengxiong [1 ]
Ren, Pan [1 ]
Li, Wei [1 ]
Deng, Hengyi [2 ]
Zhou, Zhongrong [1 ]
机构
[1] Southwest Jiaotong Univ, Tribol Res Inst, Key Lab Adv Technol Mat, Minist Educ, Chengdu 610031, Peoples R China
[2] Chengdu Second Peoples Hosp, Dept Gen Surg, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
human esophagus; frictional behavior; finite element model; patient-specific; SMALL-INTESTINE; FOREIGN-BODIES; IN-VIVO; STENTS; RESISTANCE; DESIGN;
D O I
10.37190/ABB-01535-2020-03
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose: Endoscopy is a common and effective method to treat digestive system diseases. Not only can it detect the physiological state of the digestive tract, but also can conduct clinical operations. As a result, it's of great significance to make clear the relationship between the clinical operation and the complications. Methods: Considering the difficulty in measuring the contact force and determining the stress distribution in real time during endoscopy, a specific-patient finite element model for the frictional behavior at the endoscope-esophagus interface was built in current study. By collecting the CT data of the patient, a 3D esophagus model was built and divided into three characteristic regions (narrow region, thoracic region and abdominal region) according to the physiological structure. Results: Results showed that the radius of the narrowest position was the dominant factor for the maximum von Mises stress when the endoscope passed through the narrow region. For abdominal region and thoracic region, with the increasing coefficient of friction (COF) and amplitude, the total force duo to frictional force (CFSM), frictional dissipation (FD), strain energy (SE) and maximum von Mises stress (Max) all increased correspondingly. Meanwhile, the region of stress concentration gradually approached the initial contact stage. Conclusions: The results can provide theoretical basis and technical support for clinical application and offer some suggestions for medical workers during endoscopy as well.
引用
收藏
页码:11 / 24
页数:14
相关论文
共 30 条
[1]  
Andreoni B, 1997, Dis Esophagus, V10, P95
[2]   Management of esophageal foreign bodies: a retrospective review of 400 cases [J].
Athanassiadi, K ;
Gerazounis, M ;
Metaxas, E ;
Kalantzi, N .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (04) :653-656
[3]   Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach [J].
Auricchio, F. ;
Conti, M. ;
Morganti, S. ;
Reali, A. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (12) :1347-1357
[4]   Patient-specific finite element analysis of carotid artery stenting: a focus on vessel modeling [J].
Auricchio, F. ;
Conti, M. ;
Ferrara, A. ;
Morganti, S. ;
Reali, A. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2013, 29 (06) :645-664
[5]  
Auricchio F., 2001, COMPUT METHOD BIOMEC, V4, P249, DOI [10.1080/10255840108908007, DOI 10.1080/10255840108908007]
[6]   High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Compton, CC ;
Nishioka, NS .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) :467-474
[7]   A biomechanical approach to the analysis of methods and procedures of bariatric surgery [J].
Carniel, Emanuele Luigi ;
Frigo, Alessandro ;
Fontanella, Chiara Giulia ;
De Benedictis, Giulia Maria ;
Rubini, Alessandro ;
Barp, Luca ;
Pluchino, Gioela ;
Sabbadini, Beatrice ;
Polese, Lino .
JOURNAL OF BIOMECHANICS, 2017, 56 :32-41
[8]   Esophageal Stents for Leaks and Perforations [J].
Dai, Yiyang ;
Chopra, Sascha S. ;
Steinbach, Markus ;
Kneif, Soeren ;
Huenerbein, Michael .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2011, 23 (02) :159-162
[9]   Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study [J].
Dottori, Serena ;
Flamini, Vittoria ;
Vairo, Giuseppe .
INTERNATIONAL JOURNAL FOR COMPUTATIONAL METHODS IN ENGINEERING SCIENCE & MECHANICS, 2016, 17 (03) :196-210
[10]   The use of self-expandable metallic stents for palliative treatment of inoperable esophageal cancer [J].
Eroglu, A. ;
Turkyilmaz, A. ;
Subasi, M. ;
Karaoglanoglu, N. .
DISEASES OF THE ESOPHAGUS, 2010, 23 (01) :64-70