Simplified optimum sizing and cost analysis for compact heat exchanger in VHTR

被引:45
作者
Kim, E. S. [1 ]
Oh, C. H. [1 ]
Sherman, S. [2 ]
机构
[1] Idaho Natl Lab, Idaho Falls, ID 83415 USA
[2] Savannah River Natl Lab, Aiken, SC 29808 USA
关键词
Cost reduction - Carbon dioxide - Cost benefit analysis - Gas cooled reactors - Heat exchangers - Heat transfer - High temperature gas reactors;
D O I
10.1016/j.nucengdes.2008.05.012
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this study, the optimum size of the compact heat exchanger has been developed based on its weight and pumping power for the reference design of 600 MWt very high temperature gas-cooled reactor (VHTR) system. Alloy 617 was selected as a construction material. The optimum size and a number of configurations for the reference design of the VHTR with an intermediate heat exchanger (IHX) were investigated and our initial calculations indicated that it has an unrealistically too large aspect ratio of the length and height due to its small-sized channels, which might cause manifolding problems and a large number of parallel modules with high thermal stress. The flow area and channel diameter were then adjusted to achieve a smaller aspect ratio in this paper. Achievement of this aspect ratio resulted in higher cost, but the cost increase was less than would have occurred by simply reducing the flow area by itself. The appropriate channel diameter is estimated to be less than 5.00 mm for the reference system. The effect of channel waviness enhanced the compactness and heat transfer performance, but unfavorably increased the aspect ratio. Therefore, the waviness should be carefully determined based on performance and economics. In this study, the waviness of the IHX is recommended to be selected between 1.0 and 2.5. Calculations show that reducing the duty dramatically decreases the aspect ratio, indicating that the compact heat exchanger is easy to be optimally designed for low duty, but many modules are required for high duty operation proportional to the operating power. Finally, the effect of working fluids was investigated, and it reveals that using carbon dioxide instead of helium in the secondary side reduces the size and cost by about 20% due to the lower pumping power in spite of its lower heat transfer capability by a factor of 4. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:2635 / 2647
页数:13
相关论文
共 13 条
[1]  
[Anonymous], 2008, NIST STANDARD REFERE
[2]  
[Anonymous], 2004, SUPER CRITICAL CARBO
[3]  
*ASP TECHN, 2005, HYSYS PROC VERS 2 2
[4]  
Bejan A., 2003, Heat transfer handbook, V1
[5]  
DEWSON JJ, 2003, HEATRIC WORKSH MIT C
[6]  
*EIA, 2007, AV RET PRIC EL ULT C
[7]  
Hesselgreaves John., 2017, Compact Heat Exchangers Selection, Design and Operation, V2
[8]  
Kakac S., 2002, HEAT EXCHANGERS SELE
[9]  
Kays W.M., 1984, COMPACT HEAT EXCHANG, V3rd
[10]   Printed circuit heat exchanger thermal-hydraulic performance in supercritical CO2 experimental loop [J].
Nikitin, Konstantin ;
Kato, Yasuyoshi ;
Ngo, Lam .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (05) :807-814