Behavior of plywood lining subject to ISO room corner fire test

被引:0
|
作者
Xu, L [1 ]
Zhang, HP [1 ]
Yuan, BP [1 ]
Yang, Y [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230027, Anhui, Peoples R China
来源
PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B | 2005年 / 5卷
关键词
plywood lining; surface flame spread; room corner fire; full-scale test; ENCLOSURE;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Lining materials, widely used in room decoration, with their intrinsic combustibility may produce a potentially high fire hazard in buildings. In this paper, full-scale fire experiments were carried out in an ISO room to study the behavior of plywood ling in real fire conditions. Typical thin and thick plywood linings with the thickness of 5mm and 12mm respectively were chosen and installed in two ways, one with linings mounted on walls only, the other with linings mounted on both walls and ceiling. By measuring important experimental data associated with the enclosure fire growth, including heat release rate, room temperatures, lining surface temperatures, the height of hot and cold smoke layer etc, the effects of lining materials' thickness and set-up on fire spread have been researched. The study not only investigated the effect of the lining on the enclosure fire growth, but also proposed useful experimental data for the numerical simulation of enclosure fire growth lined with combustible lining materials.
引用
收藏
页码:1060 / 1067
页数:8
相关论文
共 50 条
  • [1] Effects of surface flame spread of block board lining on enclosure fire in ISO room corner fire test
    Yang, Y
    Zhang, HP
    Xu, L
    Wang, W
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1201 - 1207
  • [2] Effects of surface flame spread of plywood lining on enclosure fire in a modified ISO room
    Zhang, J
    Yang, FK
    Shields, TJ
    Silcock, GWH
    Azhakesan, MA
    JOURNAL OF FIRE SCIENCES, 2003, 21 (01) : 67 - 83
  • [3] Room Corner Fire Growth Studies of Plywood Lining Material Under Fully Ventilated Condition
    Aravind Kumar A.
    Kumar R.
    Ansari A.A.
    Journal of The Institution of Engineers (India): Series A, 2021, 102 (02) : 545 - 551
  • [4] Empirical prediction of smoke production in the ISO room corner fire test by use of ISO cone calorimeter fire test data
    Heskestad, AW
    Hovde, PJ
    FIRE AND MATERIALS, 1999, 23 (04) : 193 - 199
  • [5] A SIMULATION-MODEL FOR FIRE GROWTH ON MATERIALS SUBJECT TO A ROOM-CORNER TEST
    QUINTIERE, JG
    FIRE SAFETY JOURNAL, 1993, 20 (04) : 313 - 339
  • [6] FIRE TEST COMPARISON OF A MINI-COMPARTMENT CORNER TEST TO A FULL SCALE ENCLOSED ROOM FIRE TEST
    HANUSA, LH
    JOURNAL OF CELLULAR PLASTICS, 1983, 19 (05) : 296 - 296
  • [7] Wood crib fire free burning test in ISO room
    Qiang, Xu
    Griffin, Greg
    Bradbury, Glenn
    Dowling, Vince
    THERMOSENSE XXVIII, 2006, 6205
  • [8] Full scale experimental study on fire behavior of plywood lining in enclosure and corresponding model simulation
    State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230027, China
    Ranshao Kexue Yu Jishu, 2006, 5 (427-431):
  • [9] CHARACTERIZATION OF LIFE THREATENING CONDITIONS DURING A COMPARTMENT CORNER ROOM FIRE TEST
    CONDIT, DA
    PACKHAM, SC
    CIANCIOLO, AD
    HOFRICHTER, CH
    JOURNAL OF COMBUSTION TOXICOLOGY, 1978, 5 (02): : 141 - 161
  • [10] Prediction of time to flashover in the ISO 9705 room corner test based on cone calorimeter test results
    Hansen, AS
    Hovde, PJ
    FIRE AND MATERIALS, 2002, 26 (02) : 77 - 86