Compact standing-wave Fourier-transform interferometer with harmonic spectral analysis

被引:0
|
作者
Fu, Junxian [1 ,2 ]
Yu, Xiaojun [1 ]
Zhang, Bingyang [1 ]
Harris, James S., Jr. [1 ]
机构
[1] Stanford Univ, Solid State & Photon Lab, 420 Via Ortega St, Stanford, CA 94305 USA
[2] Exponent Failure Anal Associates Inc, Menlo Pk, CA 94025 USA
来源
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X | 2006年 / 6079卷
关键词
interferometer; Fourier-transform; coherent detection; harmonic spectral analysis;
D O I
10.1117/12.649113
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new technique utilizing harmonic Fourier spectra created by the non-linear properties of a compact Fourier-transform infrared interferometer (FTIR) was proposed and realized to improve the system resolution. The compact standing wave FTIR (SWFTIR) system consists of a partial transparent hetero-junction bipolar phototransistor (HPT) and a free scanning highly reflective mirror. The overall size of the system is less than 5x5x5cm(3), and the resolution at 1.5 mu m is better than 37.5cm(-1) at the 5(th) harmonic spectral component. The SWFTIR array system has theoretical resolution of better than 1 cm(-1) covering the whole near-infrared region with potential compact portable applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Standing-wave Fourier transform interferometer with an HPT
    Fu, JX
    Yu, XJ
    Zhang, BY
    Harris, JS
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2006, 18 (1-4) : 40 - 42
  • [2] Heterodyne standing-wave interferometer
    Ortlepp, Ingo
    Manske, Eberhard
    Zoellner, Jens-Peter
    Rangelow, Ivo
    TM-TECHNISCHES MESSEN, 2018, 85 : S80 - S85
  • [3] Design aspects in the development of a standing-wave interferometer
    Mandryka, V
    Büchner, H
    Jäger, G
    OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 175 - 183
  • [4] An optical standing-wave interferometer for displacement measurements
    Büchner, HJ
    Stiebig, H
    Mandryka, V
    Bunte, E
    Jäger, G
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (03) : 311 - 316
  • [5] Optical Fiber Interferometer for Fourier Transform Spectral Analysis
    Zhu, Ling
    Liu, Yong
    Zhang, Long
    Chen, Mingxing
    Wang, An
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 1035 - 1036
  • [6] Standing-wave interferometer based on partially transparent photodiodes
    Büchner, HJ
    Bunte, E
    Mandryka, V
    Stiebig, H
    Jäger, G
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION III, 2003, 5144 : 218 - 226
  • [7] Heterodyne Standing-Wave Interferometer with Improved Phase Stability
    Ortlepp I.
    Zöllner J.-P.
    Rangelow I.W.
    Manske E.
    Ortlepp, Ingo (ingo.ortlepp@tu-ilmenau.de), 1600, Springer Science and Business Media B.V. (04): : 190 - 199
  • [8] Compact representation of spectral BRDFs using Fourier transform and spherical harmonic expansion
    Xu, Huiying
    Sun, Yinlong
    COMPUTER GRAPHICS FORUM, 2006, 25 (04) : 759 - 775
  • [9] Design and investigation of an optical standing-wave interferometer for displacement measurements
    Büchner, HJ
    Mandryka, V
    Jägerl, G
    PHYSICS AND APPLICATIONS OF OPTOELECTRONIC DEVICES, 2004, 5594 : 57 - 65
  • [10] COMPACT FOURIER-TRANSFORM INFRARED SPECTROMETER INSIDE A GLOVE BOX - FOURIER-TRANSFORM SPECTROELECTROCHEMISTRY AND OTHER APPLICATIONS
    SARAVANAMUTHU, A
    BRUCE, AE
    BRUCE, MRM
    VIBRATIONAL SPECTROSCOPY, 1991, 2 (2-3) : 101 - 106