Feasibility and safety of ultrasound-guided minimally invasive autopsy in COVID-19 patients

被引:32
作者
Brook, Olga R. [1 ]
Piper, Kimberly G. [2 ]
Mercado, Noe B. [3 ]
Gebre, Makda S. [3 ]
Barouch, Dan H. [3 ]
Busman-Sahay, Kathleen [4 ,5 ]
Starke, Carly E. [4 ,5 ]
Estes, Jacob D. [4 ,5 ]
Martinot, Amanda J. [3 ,6 ,7 ]
Wrijil, Linda [6 ,7 ]
Ducat, Sarah [6 ,7 ]
Hecht, Jonathan L. [8 ]
机构
[1] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Radiol, 330 Brookline Ave, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Dept Vasc Surg, Boston, MA 02215 USA
[3] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Ctr Virol & Vaccine Res, Boston, MA 02215 USA
[4] Oregon Hlth & Sci Univ, Oregon Natl Primate Res Ctr, Vaccine & Gene Therapy Inst, Beaverton, OR 97006 USA
[5] Oregon Hlth & Sci Univ, Oregon Natl Primate Res Ctr, Div Pathobiol & Immunol, Beaverton, OR 97006 USA
[6] Tufts Univ, Cummings Sch Vet Med, Dept Infect Dis, North Grafton, MA 01536 USA
[7] Tufts Univ, Cummings Sch Vet Med, Dept Global Hlth & Biomed Sci, North Grafton, MA 01536 USA
[8] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Pathol, Boston, MA 02115 USA
关键词
Autopsy; Biopsy; COVID-19;
D O I
10.1007/s00261-020-02753-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To determine the feasibility and safety of ultrasound-guided minimally invasive autopsy in COVID-19 patients. Methods 60 patients who expired between 04/22/2020-05/06/2020 due to COVID-19 were considered for inclusion in the study, based on availability of study staff. Minimally invasive ultrasound-guided autopsy was performed with 14G core biopsies through a 13G coaxial needle. The protocol required 20 cores of the liver, 30 of lung, 12 of spleen, 20 of heart, 20 of kidney, 4 of breast, 4 of testis, 2 of skeletal muscle, and 4 of fat with total of 112 cores per patient. Quality of the samples was evaluated by number, size, histology, immunohistochemistry, and in situ hybridization for COVID-19 and PCR-measured viral loads for SARS-CoV-2. Results Five (5/60, 8%) patients were included. All approached families gave their consent for the minimally invasive autopsy. All organs for biopsy were successfully targeted with ultrasound guidance obtaining all required samples, apart from 2 patients where renal samples were not obtained due to atrophic kidneys. The number, size, and weight of the tissue cores met expectation of the research group and tissue histology quality was excellent. Pathology findings were concordant with previously reported autopsy findings for COVID-19. Highest SARS-CoV-2 viral load was detected in the lung, liver, and spleen that had small to moderate amount, and low viral load in was detected in the heart in 2/5 (40%). No virus was detected in the kidney (0/3, 0%). Conclusions Ultrasound-guided percutaneous post-mortem core biopsies can safely provide adequate tissue. Highest SARS-CoV-2 viral load was seen in the lung, followed by liver and spleen with small amount in the myocardium.
引用
收藏
页码:1263 / 1271
页数:9
相关论文
共 18 条
[1]   Pulmonary Vascular Endothelialitis, Thrombosis, and Angiogenesis in Covid-19 [J].
Ackermann, Maximilian ;
Verleden, Stijn E. ;
Kuehnel, Mark ;
Haverich, Axel ;
Welte, Tobias ;
Laenger, Florian ;
Vanstapel, Arno ;
Werlein, Christopher ;
Stark, Helge ;
Tzankov, Alexandar ;
Li, William W. ;
Li, Vincent W. ;
Mentzer, Steven J. ;
Jonigk, Danny .
NEW ENGLAND JOURNAL OF MEDICINE, 2020, 383 (02) :120-128
[2]   Acute Kidney Injury in COVID-19: Emerging Evidence of a Distinct Pathophysiology [J].
Batlle, Daniel ;
Soler, Maria Jose ;
Sparks, Matthew A. ;
Hiremath, Swapnil ;
South, Andrew M. ;
Welling, Paul A. ;
Swaminathan, Sundararaman .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2020, 31 (07) :1380-1383
[3]  
Bradley B. T., 2020, HISTOPATHOLOGY ULTRA, DOI [10.1101/2020.04.17.20058545, DOI 10.1101/2020.04.17.20058545]
[4]   Validity of a Minimally Invasive Autopsy for Cause of Death Determination in Adults in Mozambique: An Observational Study [J].
Castillo, Paola ;
Martinez, Miguel J. ;
Ussene, Esperanca ;
Jordao, Dercio ;
Lovane, Lucilia ;
Ismail, Mamudo R. ;
Carrilho, Carla ;
Lorenzoni, Cesaltina ;
Fernandes, Fabiola ;
Bene, Rosa ;
Palhares, Antonio ;
Ferreira, Luiz ;
Lacerda, Marcus ;
Mandomando, Inacio ;
Vila, Jordi ;
Carlos Hurtado, Juan ;
Munguambe, Khatia ;
Maixenchs, Maria ;
Sanz, Ariadna ;
Quinto, Llorenc ;
Macete, Eusebio ;
Alonso, Pedro ;
Bassat, Quique ;
Menendez, Clara ;
Ordi, Jaume .
PLOS MEDICINE, 2016, 13 (11)
[5]   SARS-CoV-2 infection protects against rechallenge in rhesus macaques [J].
Chandrashekar, Abishek ;
Liu, Jinyan ;
Martinot, Amanda J. ;
McMahan, Katherine ;
Mercado, Noe B. ;
Peter, Lauren ;
Tostanoski, Lisa H. ;
Yu, Jingyou ;
Maliga, Zoltan ;
Nekorchuk, Michael ;
Busman-Sahay, Kathleen ;
Terry, Margaret ;
Wrijil, Linda M. ;
Ducat, Sarah ;
Martinez, David R. ;
Atyeo, Caroline ;
Fischinger, Stephanie ;
Burke, John S. ;
Slein, Matthew D. ;
Pessaint, Laurent ;
Van Ry, Alex ;
Greenhouse, Jack ;
Taylor, Tammy ;
Blade, Kelvin ;
Cook, Anthony ;
Finneyfrock, Brad ;
Brown, Renita ;
Teow, Elyse ;
Velasco, Jason ;
Zahn, Roland ;
Wegmann, Frank ;
Abbink, Peter ;
Bondzie, Esther A. ;
Dagotto, Gabriel ;
Gebre, Makda S. ;
He, Xuan ;
Jacob-Dolan, Catherine ;
Kordana, Nicole ;
Li, Zhenfeng ;
Lifton, Michelle A. ;
Mahrokhian, Shant H. ;
Maxfield, Lori F. ;
Nityanandam, Ramya ;
Nkolola, Joseph P. ;
Schmidt, Aaron G. ;
Miller, Andrew D. ;
Baric, Ralph S. ;
Alter, Galit ;
Sorger, Peter K. ;
Estes, Jacob D. .
SCIENCE, 2020, 369 (6505) :812-+
[6]  
Deleage Claire, 2016, Pathog Immun, V1, P68
[7]   Ultrasound-guided minimally invasive autopsy as a tool for rapid post-mortem diagnosis in the 2018 Sao Paulo yellow fever epidemic: Correlation with conventional autopsy [J].
Duarte-Neto, Amaro Nunes ;
de Almeida Monteiro, Renata Aparecida ;
Johnsson, Janaina ;
Cunha, Marielton dos Passos ;
Pour, Shahab Zaki ;
Saraiva, Amanda Cartagenes ;
Ho, Yeh-Li ;
Ferraz da Silva, Luiz Fernando ;
Mauad, Thais ;
de Andrade Zanotto, Paolo Marinho ;
Nascimento Saldiva, Paulo Hilario ;
Souza de Oliveira, Ilka Regina ;
Dolhnikoff, Marisa .
PLOS NEGLECTED TROPICAL DISEASES, 2019, 13 (07)
[8]   Multimodality minimally invasive autopsy-A feasible and accurate approach to post-mortem examination [J].
Fan, Joe K. M. ;
Tong, Daniel K. H. ;
Poon, Jensen T. C. ;
Lo, Oswens S. H. ;
Beh, Philip S. L. ;
Patil, N. G. ;
Law, Wai Lun .
FORENSIC SCIENCE INTERNATIONAL, 2010, 195 (1-3) :93-98
[9]   Ultrasonographic autopsy (echopsy):: a new autopsy technique [J].
Fariña, J ;
Millana, C ;
Fdez-Aceñero, MJ ;
Furió, V ;
Aragoncillo, P ;
Martín, VG ;
Buencuerpo, J .
VIRCHOWS ARCHIV, 2002, 440 (06) :635-639
[10]  
Fox, 2020, MEDRXIV