Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices

被引:100
作者
Ahn, Yoon-Ho [1 ]
Chen, Wen-Ming [2 ]
Lee, Kwon-Yong [3 ]
Park, Kyung-Woo [4 ]
Lee, Sung-Jae [5 ]
机构
[1] Korea Orthoped & Rehabil Engn Ctr, Inchon 403712, South Korea
[2] Natl Univ Singapore, Div Bioengn, Singapore 117576, Singapore
[3] Sejong Univ, Dept Mech Engn, Seoul 143747, South Korea
[4] Kwang Hye Spine Hosp, Dept Neurosurg, Seoul 135280, South Korea
[5] Inje Univ, Dept Biomed Engn, Gimhae 621749, South Korea
关键词
D O I
10.1088/1748-6041/3/4/044101
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, numerous types of posterior dynamic stabilization (PDS) devices have been introduced as an alternative to the fusion devices for the surgical treatment of degenerative lumbar spine. It is hypothesized that the use of 'compliant' materials such as Nitinol (Ni-Ti alloy, elastic modulus = 75 GPa) or polyether-etherketone (PEEK, elastic modulus = 3.2 GPa) in PDS can restore stability of the lumbar spine without adverse stress-shielding effects that have often been found with 'rigid' fusion devices made of 'rigid' Ti alloys (elastic modulus = 114 GPa). Previous studies have shown that suitably designed PDS devices made of more compliant material may be able to help retain kinematic behavior of the normal spine with optimal load sharing between the anterior and posterior spinal elements. However, only a few studies on their biomechanical efficacies are available. In this study, we conducted a finite-element (FE) study to investigate changes in load-sharing characteristics of PDS devices. The implanted models were constructed after modifying the previously validated intact model of L3-4 spine. Posterior lumbar fusion with three different types of pedicle screw systems was simulated: a conventional rigid fixation system (Ti6Al4V, Phi = 6.0 mm) and two kinds of PDS devices (one with Nitinol rod with a three-coiled turn manner, Phi = 4.0 mm; the other with PEEK rod with a uniform cylindrical shape, Phi = 6.0 mm). To simulate the load on the lumbar spine in a neutral posture, an axial compressive load (400 N) was applied. Subsequently, the changes in load-sharing characteristics and stresses were investigated. When the compressive load was applied on the implanted models (Nitinol rod, PEEK rod, Ti-alloy rod), the predicted axial compressive loads transmitted through the devices were 141.8 N, 109.8 N and 266.8 N, respectively. Axial forces across the PDS devices (Nitinol rod, PEEK rod) and rigid system (Ti-alloy rod) with facet joints were predicted to take over 41%, 33% and 71% of the applied compression load, respectively. Our results confirmed the hypothesis on the PDS devices by showing the substantial reduction in stress-shielding characteristics. Higher axial load was noted across the anterior structure with the PDS devices, which could slow the degeneration process of bony structures and lower the possibility of implant failure.
引用
收藏
页数:6
相关论文
共 25 条
[1]  
AHN YH, 2007, 15 ANN S COMP METH O, P16
[2]   Failure analysis of broken pedicle screws on spinal instrumentation [J].
Chen, CS ;
Chen, WJ ;
Cheng, CK ;
Jao, SHE ;
Chueh, SC ;
Wang, CC .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) :487-496
[3]   Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments [J].
Chow, DHK ;
Luk, KDK ;
Evans, JH ;
Leong, JCY .
SPINE, 1996, 21 (05) :549-555
[4]   Load-sharing characteristics of stabilized lumbar spine segments [J].
Cripton, PA ;
Jain, GM ;
Wittenberg, RH ;
Nolte, LP .
SPINE, 2000, 25 (02) :170-179
[5]   Clinical outcome after spinal fusion with a rigid versus a semi-rigid pedicle screw system [J].
Dahl B. ;
Gehrchen P. ;
Blyme P. ;
Kiær T. ;
Tøndevold E. .
European Spine Journal, 1997, 6 (6) :412-416
[6]   Effects of Charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol [J].
Goel, VK ;
Grauer, JN ;
Patel, TC ;
Biyani, A ;
Sairyo, K ;
Vishnubhotla, S ;
Matyas, A ;
Cowgill, I ;
Shaw, M ;
Long, R ;
Dick, D ;
Panjabi, MM ;
Serhan, H .
SPINE, 2005, 30 (24) :2755-2764
[7]   INTERLAMINAR SHEAR STRESSES AND LAMINAE SEPARATION IN A DISC - FINITE-ELEMENT ANALYSIS OF THE L3-L4 MOTION SEGMENT SUBJECTED TO AXIAL COMPRESSIVE LOADS [J].
GOEL, VK ;
MONROE, BT ;
GILBERTSON, LG ;
BRINCKMANN, P ;
NAT, R .
SPINE, 1995, 20 (06) :689-698
[8]  
JOHNSSON KE, 1992, CLIN ORTHOP RELAT R, V279, P82
[9]  
MCNALLY D, 2007, DYNAMIC RECONSTRUCTI, P237
[10]   Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study [J].
Niosi, Christina A. ;
Zhu, Qingan A. ;
Wilson, Derek C. ;
Keynan, Ory ;
Wilson, David R. ;
Oxland, Thomas R. .
EUROPEAN SPINE JOURNAL, 2006, 15 (06) :913-922