Ambient Dose Equivalent, Effective Dose and Mean Sv/Gy Conversion Coefficients from Scattered X-Ray Spectra in Mammography

被引:0
作者
Kunzel, R. [2 ]
Herdade, S. B. [2 ]
Costa, P. R. [3 ]
Terini, R. A. [1 ]
Levenhagen, R. S. [4 ]
机构
[1] Pontificia Univ Catolica Sao Paulo, Dept Fis, R Marques Paranagua 111, BR-01303050 Sao Paulo, Brazil
[2] Univ Sao Paulo, Inst Fis, BR-05508900 Sao Paulo, Brazil
[3] Univ Sao Paulo, Inst Elect & Energia, Secao Tecn Desenvolvimento Tecnol Saude, BR-05508010 Sao Paulo, Brazil
[4] Univ Sao Paulo, Inst Astron Geofis & Ciencias Atomsfericas, BR-05508900 Sao Paulo, Brazil
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6 | 2007年 / 14卷
基金
巴西圣保罗研究基金会;
关键词
Ambient dose equivalent; effective dose; mammography; scattered X-rays; X-ray spectroscopy;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, scattered X-ray distributions were produced by irradiating a tissue equivalent phantom under clinical mammography conditions by using Mo/Mo, Mo/Rh and W/Rh anode/filter combinations, for 25 and 30 kV tube voltages. Energy spectra of the scattered X-rays have been measured with a Cd0.9Zn0.1Te (CZT) detector for scattering angles between 300 and 165 degrees. Experimental spectra have been corrected by a stripping procedure and then compared with calculated ones produced by semi-empirical models. In order to validate the adopted spectroscopic procedure, the values of HVL and air kerma calculated through the measured spectra were compared with those measured with an ionization chamber at the same experimental set-up at a non-clinical constant potential equipment with a tungsten anode and molybdenum filtration. Values of air kerma, ambient dose equivalent and effective dose have been evaluated through the X-ray spectra obtained in a clinical mammography unit. Mean conversion coefficients relating air kerma to ambient dose equivalent and effective dose from the scattered beams for all anode/filter combinations were evaluated. The mean conversion coefficient values from air kerma to ambient dose equivalent are between 0.21 and 0.54 Sv/Gy whereas the coefficients from air kerma to effective dose are between 0.036 and 0.11 Sv/Gy for the scattered radiation in the mammography energy range. Results show that for the scattered radiation beams the ambient dose equivalent gives an overestimate of the effective dose by a factor of about 5 in the mammography energy range, These results can be used in the control of the dose limits around a clinical unit and in the calculation of more realistic protective shielding barriers in mammography.
引用
收藏
页码:2092 / +
页数:2
相关论文
共 8 条
[1]  
Costa PR, 2002, MED PHYS, V29, P73, DOI 10.1118/1.1427309
[2]  
ICRU, 1998, 57 ICRU
[3]   A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography [J].
Kharrati, H .
MEDICAL PHYSICS, 2005, 32 (05) :1367-1374
[4]   Ambient dose equivalent and effective dose from scattered x-ray spectra in mammography for Mo/Mo, Mo/Rh and W/Rh anode/filter combinations [J].
Kunzel, R ;
Herdade, SB ;
Costa, PR ;
Terini, RA ;
Levenhagen, RS .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (08) :2077-2091
[5]   X-ray spectroscopy in mammography with a silicon PIN photodiode with application to the measurement of tube voltage [J].
Künzel, R ;
Herdade, SB ;
Terini, RA ;
Costa, PR .
MEDICAL PHYSICS, 2004, 31 (11) :2996-3003
[6]   Scatter radiation intensities about mammography units [J].
Simpkin, DJ .
HEALTH PHYSICS, 1996, 70 (02) :238-244
[7]   MOLYBDENUM TARGET X-RAY-SPECTRA - A SEMIEMPIRICAL MODEL [J].
TUCKER, DM ;
BARNES, GT ;
WU, XZ .
MEDICAL PHYSICS, 1991, 18 (03) :402-407
[8]   SEMIEMPIRICAL MODEL FOR GENERATING TUNGSTEN TARGET X-RAY-SPECTRA [J].
TUCKER, DM ;
BARNES, GT ;
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1991, 18 (02) :211-218