Non-contact Vibro-acoustic Detection Technique for Dental Osseointegration Examination

被引:9
|
作者
Zhuang, Han-Bo [1 ]
Tu, Wei-Shan [1 ]
Pan, Min-Chun [1 ,2 ]
Wu, Jer-Whey [3 ]
Chen, Chin-Sung [4 ]
Lee, Shyh-Yuan [5 ]
Yang, Yuan-Chao [3 ]
机构
[1] Natl Cent Univ, Dept Mech Engn, Jhongli 320, Taiwan
[2] Natl Cent Univ, Grad Inst Biomed Engn, Jhongli 320, Taiwan
[3] Cathay Gen Hosp, Dept Dent, Taipei 106, Taiwan
[4] Sijhih Cathay Gen Hosp, Dept Dent, Sijhih 221, Taiwan
[5] Natl Yang Ming Univ, Sch Dent, Fac Dent, Taipei 112, Taiwan
关键词
Dental implant; Osseointegration; Bone defect detection; Non-contact vibro-acoustic measurement; RESONANCE FREQUENCY-ANALYSIS; IMPLANT STABILITY; NUMERICAL APPROACH; TITANIUM IMPLANTS; TOOTH MOBILITY; IN-VIVO; BONE; VALIDATION; SIMULATION; INTERFACE;
D O I
10.5405/jmbe.993
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study develops a non-contact vibro-acoustic detection technique for measuring the defect quantity and determining the imperfection orientation surrounding a bone-implant interface. Acoustic excitation through a miniature loud speaker and vibration response measurement using a capacity-type displacement sensor are applied to accomplish this task to prevent the mass loading effect on the structure to be examined. The proposed non-contact excitation-response measurements are verified using a series of designated in vitro defect models, and the measured resonance frequencies (RFs) are used to discriminate interfacial structure variations. A finite element modal analysis is conducted to validate the measured RFs. Additionally, a prototype device is developed and applied to assess the osseointegration between dental implants and tibia in an in vivo animal model. A comparison of in vitro experimental results with numerical simulations shows that the RFs in the defective orientation are significantly smaller than those in the complete direction (p < 0.05), and that the values decrease with increasing defect quantity (p < 0.05). Moreover, the defect depth affects RF variation. In the in vivo experiments, the RF levels in the lateral direction of the tibia are much higher than those in the axial direction (p < 0.05) of the tibia. The RF values in the axial direction for two implants have no significant difference (p = 0.552), but the RFs in the lateral direction for implant 2 are higher than those for implant 1 (p < 0.05). The RF changes can be compared to assess osseointegration development. The proposed technique is promising for assisting dentists in the assessment of implant stability after surgery.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 8 条
  • [1] Handheld device for assessing dental implant osseointegration through the vibro-acoustic technique
    Pan, Min-Chun
    Wang, Shih-Yao
    Chen, Chin-Sung
    MEASUREMENT, 2021, 169
  • [2] A noncontact detection technique for interfacial bone defects and osseointegration assessment surrounding dental implants
    Zhuang, H. B.
    Pan, M. Ch
    Chen, Z.
    Wu, J. W.
    Chen, C. S.
    MEASUREMENT, 2014, 55 : 335 - 342
  • [3] Pulsed Vibro-Acoustic Analysis Technique for Monitoring Bone Health in Preterm Infants: A Pilot Study
    Chaudhary, Pradeep Kumar
    Gu, Juanjuan
    Rosen, David P.
    Larson, Nicholas B.
    Brumbaugh, Jane E.
    Fatemi, Mostafa
    Alizad, Azra
    IEEE ACCESS, 2024, 12 : 106707 - 106719
  • [4] Vibro-acoustic analysis under stationary and non-stationary random excitations with KLE/FEM/BEM
    Li, Yanbin
    Mulani, Sameer B.
    Fei, Qingguo
    Wu, Shaoqing
    Zhang, Peng
    AEROSPACE SCIENCE AND TECHNOLOGY, 2017, 66 : 203 - 215
  • [5] Non-contact damage monitoring technique for FRP laminates using guided waves
    Garg, Mohit
    Sharma, Shruti
    Sharma, Sandeep
    Mehta, Rajeev
    SMART STRUCTURES AND SYSTEMS, 2016, 17 (05) : 795 - 817
  • [6] Non-contact electrical detection of intrinsic local charge and internal electric field at nanointerfaces
    Cai, Duanjun
    Xu, Fuchun
    Li, Jinchai
    Chen, Hangyang
    Kang, Junyong
    NANOTECHNOLOGY, 2010, 21 (01)
  • [7] Non-contact in-situ pulsed electro acoustic method for the analysis of charge transport in irradiated space-used polymers
    Arnaout, M.
    Paulmier, T.
    Dirassen, B.
    Payan, D.
    JOURNAL OF ELECTROSTATICS, 2015, 77 : 123 - 129
  • [8] Laser-Induced Shockwaves as a Rapid and Non-Contact Technique for 2D Patterning of Colloidal Monolayer Crystals
    Nguyen, Dien Kha Tu
    Park, Joonwoo
    Park, Gyeongmin
    Lee, Jaejun
    ADVANCED MATERIALS INTERFACES, 2024, 11 (12)