Seismic Collapse Evaluation of Steel Intermediate Moment Frames
被引:0
|
作者:
Han, Sangwhan
论文数: 0引用数: 0
h-index: 0
机构:
Hanyang Univ, Dept Architecture Engn, Seoul, South KoreaHanyang Univ, Dept Architecture Engn, Seoul, South Korea
Han, Sangwhan
[1
]
Kim, Taeo
论文数: 0引用数: 0
h-index: 0
机构:
Hanyang Univ, Dept Architecture Engn, Seoul, South KoreaHanyang Univ, Dept Architecture Engn, Seoul, South Korea
Kim, Taeo
[1
]
机构:
[1] Hanyang Univ, Dept Architecture Engn, Seoul, South Korea
来源:
PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON ARCHITECTURAL ENGINEERING AND CIVIL ENGINEERING
|
2016年
/
72卷
基金:
新加坡国家研究基金会;
关键词:
performance evaluation;
intermediate moment frames;
reduced beam section;
connection fracture;
D O I:
暂无
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
A reduced beam section with a bolted web connection (RBS-B) is permitted for use only in Intermediate Moment Frames (IMF). In order to investigate whether IMFs with RBS-B connections provide a satisfactory seismic performance, this study evaluates the seismic performance of 3-, 6- 9- and 20-story IMFs with pre-qualified RBS-B connections following the FEAM-P695 procedure. Analysis results indicate that the probability of collapses is sensitive to the design parameters of IMF buildings with RBS-B connections.