Feasibility of three-dimensional facial imaging and printing for producing customised nasal masks for continuous positive airway pressure

被引:10
作者
Duong, Kelvin [1 ]
Glover, Joel [2 ,3 ]
Perry, Alexander C. [4 ]
Olmstead, Deborah [5 ]
Ungrin, Mark [6 ]
Colarusso, Pina [2 ,3 ]
MacLean, Joanna E. [7 ,8 ]
Martin, Andrew R. [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB, Canada
[2] Univ Calgary, Cumming Sch Med, Dept Physiol & Pharmacol, Live Cell Imaging Lab, Calgary, AB, Canada
[3] Univ Calgary, Cumming Sch Med, Snyder Inst Chron Dis, Calgary, AB, Canada
[4] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[5] Stollery Childrens Hosp, Edmonton, AB, Canada
[6] Univ Calgary, Alberta Childrens Hosp, Dept Comparat Biol & Expt Med, Fac Vet Med,Biomed Engn Grad Program,Res Inst, Calgary, AB, Canada
[7] Univ Alberta, Stollery Childrens Hosp, Fac Med & Dent, Dept Pediat, Edmonton, AB, Canada
[8] Univ Alberta, Stollery Childrens Hosp, Fac Med & Dent, Women & Childrens Hlth Res Inst, Edmonton, AB, Canada
关键词
OBSTRUCTIVE SLEEP-APNEA; CPAP ADHERENCE; LEAK;
D O I
10.1183/23120541.00632-2020
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Rationale: Delivery of continuous positive airway pressure (CPAP) is the standard treatment for obstructive sleep apnoea in children and adults. Treatment adherence is a major challenge, as many patients find the CPAP mask uncomfortable. The study aim was to demonstrate the feasibility of delivered CPAP through customised nasal masks by assessing mask leak and comfort of customised masks compared to commercially available CPAP masks. Methods: Six healthy adult volunteers participated in a crossover study including commercial masks in three different sizes ( petite, small/medium and large) from the same supplier and a customised mask fabricated for each subject using three-dimensional facial scanning and modern additive manufacturing processes. Mask leak and comfort were assessed with varying CPAP levels and mask tightness. Leak was measured in real time using an inline low-resistance Pitot tube flow sensor, and each mask was ranked for comfort by the subjects. Results: Mask leak rates varied directly with CPAP level and inversely with mask tightness. When ranked for comfort, three subjects favoured the customised mask, while three favoured a commercial mask. The petite mask yielded the highest mask leaks and was ranked least comfortable by all subjects. Relative mask leaks and comfort rankings for the other commercial and customised masks varied between individuals. Mask leak was comparable when comparing the customised masks with the highest ranked commercial masks. Conclusion: Customised masks successfully delivered target CPAP settings in all six subjects, demonstrating the feasibility of this approach.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 23 条
  • [1] Nasal versus oronasal continuous positive airway pressure masks for obstructive sleep apnea: a pilot investigation of pressure requirement, residual disease, and leak
    Bakker, Jessie P.
    Neill, Alister M.
    Campbell, Angela J.
    [J]. SLEEP AND BREATHING, 2012, 16 (03) : 709 - 716
  • [2] Mask interfaces for home non-invasive ventilation in infants and children
    Castro-Codesal, Maria L.
    Olmstead, Deborah L.
    MacLean, Joanna E.
    [J]. PAEDIATRIC RESPIRATORY REVIEWS, 2019, 32 : 66 - 72
  • [3] Clinical verification of patients with obstructive sleep apnea provided with a customized cushion for continuous positive airway pressure
    Cheng, Yih-Lin
    Hsu, Ding-Yang
    Lee, Hsin-Chien
    Bien, Mauo-Ying
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (01) : 29 - 34
  • [4] Daniel J., 2012, Choosing the type of nonprobability sampling, DOI DOI 10.4135/9781452272047
  • [5] New developments in the use of positive airway pressure for obstructive sleep apnea
    Donovan, Lucas M.
    Boeder, Schafer
    Malhotra, Atul
    Patel, Sanjay R.
    [J]. JOURNAL OF THORACIC DISEASE, 2015, 7 (08) : 1323 - 1342
  • [6] Nasal versus oronasal mask in patients under auto-adjusting continuous positive airway pressure titration: a real-life study
    Duarte, Ricardo L. M.
    Mendes, Bruno A.
    Oliveira-e-Sa, Tiago S.
    Magalhaes-da-Silveira, Flavio J.
    Gozal, David
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (12) : 3507 - 3512
  • [7] CPAP Adherence in Patients with Newly Diagnosed Obstructive Sleep Apnea prior to Elective Surgery
    Guralnick, Amy S.
    Pant, Melissa
    Minhaj, Mohammed
    Sweitzer, Bobbie Jean
    Mokhlesi, Babak
    [J]. JOURNAL OF CLINICAL SLEEP MEDICINE, 2012, 8 (05): : 501 - 506
  • [8] Pitot-tube flowmeter for quantification of airflow during sleep
    Kirkness, J. P.
    Verma, M.
    McGinley, B. M.
    Erlacher, M.
    Schwartz, A. R.
    Smith, P. L.
    Wheatley, J. R.
    Patil, S. P.
    Amis, T. C.
    Schneider, H.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2011, 32 (02) : 223 - 237
  • [9] Clinical outcomes related to interface type in patients with obstructive sleep apnea/hypopnea syndrome who are using continuous positive airway pressure
    Massie, CA
    Hart, RW
    [J]. CHEST, 2003, 123 (04) : 1112 - 1118
  • [10] Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome
    McArdle, N
    Devereux, G
    Heidarnejad, H
    Engleman, HM
    Mackay, TW
    Douglas, NJ
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (04) : 1108 - 1114