Splenic autotransplantation: a systematic review

被引:10
作者
Surendran, Arthavan [1 ]
Smith, Marty [2 ]
Houli, Nezor [2 ]
Usatoff, Val [2 ,3 ]
Spelman, Denis [4 ]
Choi, Julian [2 ]
机构
[1] Western Hlth, Dept Surg, Melbourne, Vic, Australia
[2] Western Hlth, Dept Upper Gastrointestinal Hepatobiliary Surg, Melbourne, Vic, Australia
[3] Univ Melbourne, Dept Surg, Melbourne, Vic, Australia
[4] The Alfred, Dept Infect Dis, Melbourne, Vic, Australia
关键词
spleen; splenectomy; splenic autotransplantation; AUTO-TRANSPLANTATION; IMMUNE-RESPONSE; SPLEEN; SPLENECTOMY; TISSUE; POSTSPLENECTOMY; REIMPLANTATION; REGENERATION; RESTORATION; MORTALITY;
D O I
10.1111/ans.15383
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Splenectomy is a surgical procedure indicated in a variety of medical conditions including trauma. Post-operatively, there is a lifelong risk of developing overwhelming sepsis from encapsulated bacteria, most commonly due to Streptococcus pneumoniae. Splenic autotransplantation has been proposed as a method to recover splenic function in patients requiring splenectomy with otherwise normal spleens. This study aims to systematically review the literature to determine the efficacy of spleen autotransplantation. Methods MEDLINE, PubMed and the Cochrane Library were searched for all studies assessing splenic autotransplantation (January 1947 to July 2018). Data were extracted on study characteristics, outcomes assessed, including spleen scintigraphy results, blood film counts and serum immunoglobulin (Ig) levels. Results Data were obtained from 18 primary studies. All studies demonstrated return of regenerated spleen tissue in the majority of their patients (95.3%) on spleen scintigraphy. In 12 studies, 90.2% of patients had blood films return to normal following transplantation. Ig levels were shown to return to normal in all 12 studies where it was assessed. In 11 studies, 3.7% of patients had post-operative complications. In five studies, 1.3% of patients had post-operative infections in the follow-up period. Conclusion Splenic autotransplantation is a safe procedure with minimal complications that can return splenic filtration function and Ig levels to normal ranges. It has not been confirmed whether autotransplantation provides meaningful protection against overwhelming post-splenectomy infections.
引用
收藏
页码:460 / 466
页数:7
相关论文
共 51 条
[1]   Risk of infection and death among post-splenectomy patients [J].
Bisharat, N ;
Omari, H ;
Lavi, I ;
Raz, R .
JOURNAL OF INFECTION, 2001, 43 (03) :182-186
[2]   Autotransplant of spleen tissue in children with schistosomiasis:: Evaluation of splenic function after splenosis [J].
Brandt, CT ;
Maciel, DT ;
Caneca, OAF ;
de Castro, CMMB ;
de Araújo, LB .
MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2001, 96 :117-122
[3]  
BUDIHNA N, 1991, J NUCL MED, V32, P204
[4]   SPLEEN-SAVING PROCEDURES IN PEDIATRIC SPLENIC TRAUMA [J].
BUYUKUNAL, C ;
DANISMEND, N ;
YEKER, D .
BRITISH JOURNAL OF SURGERY, 1987, 74 (05) :350-352
[5]   Splenectomy Associated Changes in IgM Memory B Cells in an Adult Spleen Registry Cohort [J].
Cameron, Paul U. ;
Jones, Penelope ;
Gorniak, Malgorzata ;
Dunster, Kate ;
Paul, Eldho ;
Lewin, Sharon ;
Woolley, Ian ;
Spelman, Denis .
PLOS ONE, 2011, 6 (08)
[6]   RETURN OF SPLENIC FUNCTION AFTER SPLENECTOMY - HOW MUCH TISSUE IS NEEDED [J].
CORAZZA, GR ;
TAROZZI, C ;
VAIRA, D ;
FRISONI, M ;
GASBARRINI, G .
BRITISH MEDICAL JOURNAL, 1984, 289 (6449) :861-864
[7]   SEVERE LATE POSTSPLENECTOMY INFECTION [J].
CULLINGFORD, GL ;
WATKINS, DN ;
WATTS, ADJ ;
MALLON, DF .
BRITISH JOURNAL OF SURGERY, 1991, 78 (06) :716-721
[8]   Assessment of splenic function [J].
de Porto, A. P. N. A. ;
Lammers, A. J. J. ;
Bennink, R. J. ;
ten Berge, I. J. M. ;
Speelman, P. ;
Hoekstra, J. B. L. .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (12) :1465-1473
[9]   A New Technique for Spleen Autotransplantation [J].
Di Carlo, Isidoro ;
Pulvirenti, Elia ;
Toro, Adriana .
SURGICAL INNOVATION, 2012, 19 (02) :156-161
[10]   Post-splenectomy and hyposplenic states [J].
Di Sabatino, Antonio ;
Carsetti, Rita ;
Corazza, Gino Roberto .
LANCET, 2011, 378 (9785) :86-97