Impact of hybrid fluorodeoxyglucose positron-emission tomography/computed tomography on radiotherapy planning in esophageal and non-small-cell lung cancer

被引:77
作者
Gondi, Vinai [1 ]
Bradley, Kristin [1 ]
Mehta, Minesh [1 ]
Howard, Andy [1 ]
Khuntia, Deepak [1 ]
Ritter, Mark [1 ]
Tome, Wolfgang [1 ]
机构
[1] Univ Wisconsin, Dept Human Oncol, Madison, WI 53706 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 67卷 / 01期
关键词
positron emission tomography; computed tomography; radiotherapy planning; esophageal cancer; non-small-cell lung cancer;
D O I
10.1016/j.ijrobp.2006.09.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to investigate the impact of a hybrid fluorodeoxyglucose positron-emission tomography/computed tomography (FDG-PET/CT) scanner in radiotherapy planning for esophageal and non-small-cell lung cancer (NSCLC). Methods and Materials: A total of 30 patients (16 with esophageal cancer, 14 with NSCLC) underwent an FDG-PET/CT for radiotherapy planning purposes. Noncontrast total-body spiral CT scans were obtained first, followed immediately by FDG-PET imaging which was automatically co-registered to the CT scan. A physician not involved in the patients' original treatment planning designed a gross tumor volume (GTV) based first on the CT dataset alone, while blinded to the FDG-PET dataset. Afterward, the physician designed a GTV based on the fused PET/CT dataset. To standardize PET GTV margin definition, background liver PET activity was standardized in all images. The CT-based and PET/CT-based GTVs were then quantitatively compared by way of an index of conformality, which is the ratio of the intersection of the two GTVs to their union. Results: The mean index of conformality was 0.44 (range, 0.00-0.70) for patients with NSCLC and 0.46 (range, 0.13-0.80) for patients with esophageal cancer. In 10 of the 16 (62.5%) esophageal cancer patients, and in 12 of the 14 (85.7%) NSCLC patients, the addition of the FDG-PET data led to the definition of a smaller GTV. Conclusion: The incorporation of a hybrid FDG-PET/CT scanner had an impact on the radiotherapy planning of esophageal cancer and NSCLC. In future studies, we recommend adoption of a conformality index for a more comprehensive comparison of newer treatment planning imaging modalities to conventional options. (c) 2007 Elsevier Inc.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 37 条
[31]   Noninvasive staging of non-small cell lung cancer - A review of the current evidence [J].
Toloza, EM ;
Harpole, L ;
McCrory, DC .
CHEST, 2003, 123 (01) :137S-146S
[32]   Lymph node staging in non-small-cell lung cancer with FDG-PET scan: A prospective study on 690 lymph node stations from 68 patients [J].
Vansteenkiste, JF ;
Stroobants, SG ;
De Leyn, PR ;
Dupont, PJ ;
Bogaert, J ;
Maes, A ;
Deneffe, GJ ;
Nackaerts, KL ;
Verschakelen, LA ;
Lerut, TE ;
Mortelmans, LA ;
Demedts, MG .
JOURNAL OF CLINICAL ONCOLOGY, 1998, 16 (06) :2142-2149
[33]   The impact of 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) lymph node staging on the radiation treatment volumes in patients with non-small cell lung cancer [J].
Vanuytsel, LJ ;
Vansteenkiste, JF ;
Stroobants, SG ;
De Leyn, PR ;
De Wever, W ;
Verbeken, EK ;
Gatti, GG ;
Huyskens, DP ;
Kutcher, GJ .
RADIOTHERAPY AND ONCOLOGY, 2000, 55 (03) :317-324
[34]   Is there a role for FGD-PET in radiotherapy planning in esophageal carcinoma? [J].
Vrieze, O ;
Haustermans, K ;
De Wever, W ;
Lerut, T ;
Van Cutsem, E ;
Ectors, N ;
Hiele, M ;
Flamen, P .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 (03) :269-275
[35]   An analysis of multiple staging management strategies for carcinoma of the esophagus: Computed tomography, endoscopic ultrasound, positron emission tomography, and thoracoscopy/laparoscopy [J].
Wallace, MB ;
Nietert, PJ ;
Earle, C ;
Krasna, MJ ;
Hawes, RH ;
Hoffman, BJ ;
Reed, CE .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1026-1032
[36]   Initial experience of FDG-PET/CT guided IMRT of head-and-neck carcinoma [J].
Wang, Dian ;
Schultz, Christopher J. ;
Jursinic, Paul A. ;
Bialkowski, Mirek ;
Zhu, X. Ronald ;
Brown, W. Douglas ;
Rand, Scott D. ;
Michel, le A. Michel ;
Campbell, Bruce H. ;
Wong, Stuart ;
Li, X. Allen ;
Wilson, J. Frank .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01) :143-151
[37]   Deformable fusion of 4D PET images [J].
Zhang, T ;
Pyzalski, R ;
Jaskowiak, C ;
Tome, W ;
Mackie, T ;
Paliwal, B .
MEDICAL PHYSICS, 2005, 32 (06) :2082-2082