Spherical harmonics based intrasubject 3-D kidney modeling/registration technique applied on partial information

被引:20
作者
Dillenseger, Jean-Louis [1 ]
Guillaume, Helene
Patard, Jean-Jacques
机构
[1] Univ Rennes 1, LTSI, INSERM, U642, F-35042 Rennes, France
[2] Rennes Univ Hosp, Hop Pontchaillou, Dept Urol, F-35033 Rennes, France
关键词
nephron-sparing surgery; spherical harmonics; 3-D modeling; 3-D rigid registration;
D O I
10.1109/TBME.2006.883653
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a three-dimensional (3-D) shape reconstruction/intrapatient rigid registration technique used to establish a Nephron-Sparing Surgery preoperative planning. The usual preoperative imaging system is the Spiral CT Urography, which provides successive 3-D acquisitions of complementary information on kidney anatomy. Because the kidney is difficult to demarcate from the liver or from the spleen only limited information on its volume or surface is available. In this paper, we propose a methodology allowing a global kidney spatial representation on a spherical harmonics basis. The spherical harmonies are exploited to recover the kidney 3-D shape and also to perform intrapatient 3-D rigid registration. An evaluation performed on synthetic data showed that this technique presented lower performance then expected for the 3-D shape recovering but exhibited registration results slightly more accurate as the iterative closest point technique with faster computation time.
引用
收藏
页码:2185 / 2193
页数:9
相关论文
共 20 条
[1]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]   An algorithmic overview of surface registration techniques for medical imaging [J].
Audette, MA ;
Ferrie, FP ;
Peters, TM .
MEDICAL IMAGE ANALYSIS, 2000, 4 (03) :201-217
[3]   Efficacy of nephron-sparing surgery for renal cell carcinoma: Analysis based on the new 1997 tumor-node-metastasis staging system [J].
Belldegrun, A ;
Tsui, KH ;
deKernion, JB ;
Smith, RB .
JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (09) :2868-2875
[4]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[5]   PARAMETRIZATION OF CLOSED SURFACES FOR 3-D SHAPE-DESCRIPTION [J].
BRECHBUHLER, C ;
GERIG, G ;
KUBLER, O .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (02) :154-170
[6]   3-DIMENSIONAL INVARIANTS AND THEIR APPLICATION TO OBJECT RECOGNITION [J].
BUREL, G ;
HENOCQ, H .
SIGNAL PROCESSING, 1995, 45 (01) :1-22
[7]   Determination of the orientation of 3D objects using spherical harmonics [J].
Burel, G ;
Henocq, H .
GRAPHICAL MODELS AND IMAGE PROCESSING, 1995, 57 (05) :400-408
[8]  
Burel G., 1995, LECT NOTES COMPUTER, V905, P252
[9]  
DILLENSEGER JL, 1991, PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 13, PTS 1-5, P1125, DOI 10.1109/IEMBS.1991.684374
[10]  
DILLENSEGER JL, 1998, EUR 98 LISB PORT