Characteristics of pulsatile blood flow through the curved bileaflet mechanical heart valve installed in two different types of blood vessels: Velocity and pressure of blood flow

被引:15
作者
Bang, Jin Seok
Yoo, Song Min
Kim, Chang Nyung [1 ]
机构
[1] Kyung Hee Univ, Coll Adv Technol, Yongin 449701, Kyunggi, South Korea
[2] Kyung Hee Univ, Ind Liaison Res Inst, Yongin 449701, Kyunggi, South Korea
[3] Kyung Hee Univ, Grad Sch, Dept Mech Engn, Yongin, Kyunggi, South Korea
关键词
D O I
10.1097/01.mat.0000219072.80294.82
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate the flow fields of blood flowing through the curved bileaflet mechanical heart valve. A numerical analysis was carried out with the fluid-structure interaction between the blood flow and the motion of leaflets in two different types of blood vessels (type A, with sinus blood vessel, and type B, without sinus blood vessel). When the leaflet was fully opened, a fluttering phenomenon was detected in association with the blood flow, and recirculation flows were observed in the sinus region of the blood vessel for type A. During the closing phase, regurgitation was formed between the ring and the edge of the each leaflet for both types. When the leaflet came into contact with the valve ring at the end of the closing phase, rebound of the leaflet occurred. in consideration of the entire domain, the pressure drop occurs mainly in the valve region. The present results showed tendencies similar to those obtained by previous experiments for blood flow and contribute to the development of the curved bileaflet mechanical heart valve prostheses.
引用
收藏
页码:234 / 242
页数:9
相关论文
共 22 条
[1]  
Chandran K B, 1994, J Heart Valve Dis, V3 Suppl 1, pS65
[2]   Pulsatile blood flows through a bileaflet mechanical heart valve with different approach methods of numerical analysis; Pulsatile flows with fixed leaflets and interacted with moving leaflets [J].
Choeng Ryul Choi ;
Chang Nyung Kim ;
Young Joo Kwon ;
Jae Won Lee .
KSME International Journal, 2003, 17 (7) :1073-1082
[3]   A two-dimensional fluid-structure interaction model of the aortic value [J].
De Hart, J ;
Peters, GWM ;
Schreurs, PJG ;
Baaijens, FPT .
JOURNAL OF BIOMECHANICS, 2000, 33 (09) :1079-1088
[4]  
DIMITRI WR, 1990, J CARDIOVASC SURG, V31, P41
[5]   Evolution of prosthetic heart valves [J].
Edmunds, LH .
AMERICAN HEART JOURNAL, 2001, 141 (05) :849-855
[6]  
GARRISON LA, 1994, J HEART VALVE DIS S1, V3, pS8
[7]   ESTIMATION OF SHEAR STRESS-RELATED BLOOD DAMAGE IN HEART-VALVE PROSTHESES - INVITRO COMPARISON OF 25 AORTIC VALVES [J].
GIERSIEPEN, M ;
WURZINGER, LJ ;
OPITZ, R ;
REUL, H .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1990, 13 (05) :300-306
[8]   The hemodynamic performance of standard bileaflet valves is impaired by a tilted implantation position [J].
Hartrumpf, M ;
Albes, JM ;
Krempl, T ;
Rudolph, V ;
Wahlers, T .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (03) :283-291
[9]  
Kafesjian R, 1994, J HEART VALVE DIS S1, V3, P2
[10]  
KLEPETKO W, 1989, J THORAC CARDIOV SUR, V97, P90