Standardized Loads Acting in Knee Implants

被引:265
作者
Bergmann, Georg [1 ]
Bender, Alwina [1 ]
Graichen, Friedmar [1 ]
Dymke, Joern [1 ]
Rohlmann, Antonius [1 ]
Trepczynski, Adam [1 ]
Heller, Markus O. [2 ]
Kutzner, Ines [1 ]
机构
[1] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[2] Univ Southampton, Engn Sci Unit, Southampton, Hants, England
来源
PLOS ONE | 2014年 / 9卷 / 01期
关键词
DEMANDING DAILY ACTIVITIES; JOINT-CONTACT FORCES; MEASURED IN-VIVO; WEAR SIMULATION; NORMAL WALKING; REPLACEMENT; MUSCLE; ARTHROPLASTY; PREDICTION; TELEMETRY;
D O I
10.1371/journal.pone.0086035
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The loads acting in knee joints must be known for improving joint replacement, surgical procedures, physiotherapy, biomechanical computer simulations, and to advise patients with osteoarthritis or fractures about what activities to avoid. Such data would also allow verification of test standards for knee implants. This work analyzes data from 8 subjects with instrumented knee implants, which allowed measuring the contact forces and moments acting in the joint. The implants were powered inductively and the loads transmitted at radio frequency. The time courses of forces and moments during walking, stair climbing, and 6 more activities were averaged for subjects with I) average body weight and average load levels and II) high body weight and high load levels. During all investigated activities except jogging, the high force levels reached 3,372-4,218N. During slow jogging, they were up to 5,165N. The peak torque around the implant stem during walking was 10.5 Nm, which was higher than during all other activities including jogging. The transverse forces and the moments varied greatly between the subjects, especially during non-cyclic activities. The high load levels measured were mostly above those defined in the wear test ISO 14243. The loads defined in the ISO test standard should be adapted to the levels reported here. The new data will allow realistic investigations and improvements of joint replacement, surgical procedures for tendon repair, treatment of fractures, and others. Computer models of the load conditions in the lower extremities will become more realistic if the new data is used as a gold standard. However, due to the extreme individual variations of some load components, even the reported average load profiles can most likely not explain every failure of an implant or a surgical procedure.
引用
收藏
页数:12
相关论文
共 37 条
  • [1] Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas
    Allen, G
    Sioutas, C
    Koutrakis, P
    Reiss, R
    Lurmann, FW
    Roberts, PT
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) : 682 - 689
  • [2] [Anonymous], 2009, ISO 142431
  • [3] Determination of typical patterns from strongly varying signals
    Bender, A.
    Bergmann, G.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (07) : 761 - 769
  • [4] Realistic loads for testing hip implants
    Bergmann, G.
    Graichen, F.
    Rohlmann, A.
    Bender, A.
    Heinlein, B.
    Duda, G. N.
    Heller, M. O.
    Morlock, M. M.
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2010, 20 (02) : 65 - 75
  • [5] In vivo knee moments and shear after total knee arthroplasty
    D'Lima, Darryl D.
    Patil, Shantanu
    Steklov, Nikolai
    Chien, Shu
    Colwell, Clifford W., Jr.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 : S11 - S17
  • [6] Tibial forces measured in vivo after total knee arthroplasty
    D'Lima, DD
    Patil, S
    Steklov, N
    Slamin, JE
    Colwell, CW
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (02) : 255 - 262
  • [7] The Chitranjan Ranawat Award - In vivo knee forces after total knee arthroplasty
    D'Lima, DD
    Patil, S
    Steklov, N
    Slamin, JE
    Colwell, CW
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) : 45 - 49
  • [8] TKA wear testing input after kinematic and dynamic meta-analysis: Technique and proof of concept
    Franta, L.
    Kronek, J.
    Suchanek, J.
    [J]. WEAR, 2011, 271 (9-10) : 2687 - 2692
  • [9] Grand challenge competition to predict in vivo knee loads
    Fregly, Benjamin J.
    Besier, Thor F.
    Lloyd, David G.
    Delp, Scott L.
    Banks, Scott A.
    Pandy, Marcus G.
    D'Lima, Darryl D.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (04) : 503 - 513
  • [10] Influence of Limb Alignment on Mediolateral Loading in Total Knee Replacement
    Halder, Andreas
    Kutzner, Ines
    Graichen, Friedmar
    Heinlein, Bernd
    Beier, Alexander
    Bergmann, Georg
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (11) : 1023 - 1029