Depth of anaesthesia during intubation. Comparison between propofol and thiopentone

被引:5
作者
Beck, C. E. [1 ]
Pohl, B. [1 ]
Janda, M. [1 ]
Bajorat, J. [1 ]
Hofmockel, R. [1 ]
机构
[1] Univ Barcelona, Klin & Poliklin Anasthesiol & Intens Therapie, Schillingallee 35, Barcelona, Spain
来源
ANAESTHESIST | 2006年 / 55卷 / 04期
关键词
propofol; thiopentone; bispectral index; rate pressure product; awareness;
D O I
10.1007/s00101-005-0956-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In order to study the depth of anaesthesia during endotracheal intubation, 30 patients received either thiopentone or propofol for anaesthesia induction. The BIS value as a parameter for the depth of anaesthesia and the rate pressure product (RPP) were aquired online. Patients who received thiopentone for anaesthesia induction showed significantly higher BIS values at the moment of intubation and reached BIS values > 60 significantly more frequently than patients receiving propofol. The RPP in the propofol group lay significantly below that of the thiopentone patients. For all patients there was an mean increase in BIS values of 8 index points and an increase in the RPP. Therefore, BIS values around 50 should be achieved before intubation in order to avoid the critical BIS value for awareness of > 60 despite the increase caused by the intubation procedure. Within 24 h of intubation all patients were interviewed for possible signs of awareness. None of the patients was able to remember the intubation or reported other experiences that indicated an unconscious awareness. Nevertheless, the progress of BIS values in a standardized intubation as performed in the normal clinical routine, shows that the use of thiopentone for initiating anaesthesia results in a very flat level of anaesthesia during intubation. The risk for patients to experience awareness should therefore, not be underestimated. Therefore, when using thiopentone it is recommended to also use a rapid acting muscle relaxant or to select a high ED95 to compensate for the flat level of anaesthesia. Alternatively, repetetive boluses of the hypnotic shortly before intubation should be considered or to revert to propofol. The dosage and pharmacokinetics of the analgesic should also be taken into consideration because an insufficient analgesia leads to a faster flattening of the depth of anaesthesia.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 19 条
[1]   EXAGGERATED ANESTHETIC REQUIREMENTS IN THE PREFERENTIALLY ANESTHETIZED BRAIN [J].
ANTOGNINI, JF ;
SCHWARTZ, K .
ANESTHESIOLOGY, 1993, 79 (06) :1244-1249
[2]   Awareness during general anaesthesia: a review of 81 cases from the Anaesthetic Incident Monitoring Study [J].
Bergman, IJ ;
Kluger, MT ;
Short, TG .
ANAESTHESIA, 2002, 57 (06) :549-556
[3]   A SIMPLE STUDY OF AWARENESS AND DREAMING DURING ANAESTHESIA [J].
BRICE, DD ;
HETHERINGTON, RR ;
UTTING, JE .
BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (06) :535-+
[4]   Nitrous oxide prevents movement during orotracheal intubation without affecting BIS value [J].
Coste, C ;
Guignard, B ;
Menigaux, C ;
Chauvin, M .
ANESTHESIA AND ANALGESIA, 2000, 91 (01) :130-135
[5]   Depth of anaesthesia, awareness and EEG [J].
Daunderer, M ;
Schwender, D .
ANAESTHESIST, 2001, 50 (04) :231-241
[6]  
DOMINO KB, 1996, ASA NEWSLETTER, V60, P14
[7]   Reduction in the incidence of awareness using BIS monitoring [J].
Ekman, A ;
Lindholm, ML ;
Lennmarken, C ;
Sandin, R .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (01) :20-26
[8]   Recovery of consciousness after thiopental or propofol - Bispectral index and the isolated forearm technique [J].
Flaishon, R ;
Windsor, A ;
Sigl, J ;
Sebel, PS .
ANESTHESIOLOGY, 1997, 86 (03) :613-619
[9]  
Iselin-Chaves IA, 1998, ANESTH ANALG, V87, P949
[10]   Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol-induced sedation [J].
Liu, J ;
Singh, H ;
White, PF .
ANESTHESIA AND ANALGESIA, 1997, 84 (01) :185-189