Child Activity Recognition Based on Cooperative Fusion Model of a Triaxial Accelerometer and a Barometric Pressure Sensor

被引:68
作者
Nam, Yunyoung [1 ]
Park, Jung Wook [2 ]
机构
[1] SUNY Stony Brook, Dept Elect & Comp Engn, Stony Brook, NY 11794 USA
[2] LG Elect, CTO Div, Seoul 150721, South Korea
关键词
Accelerometer; activity classification; activity recognition; baby care; child care; wearable device; PHYSICAL-ACTIVITY RECOGNITION; INTEGRATION; VALIDATION;
D O I
10.1109/JBHI.2012.2235075
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a child activity recognition approach using a single 3-axis accelerometer and a barometric pressure sensor worn on a waist of the body to prevent child accidents such as unintentional injuries at home. Labeled accelerometer data are collected from children of both sexes up to the age of 16 to 29 months. To recognize daily activities, mean, standard deviation, and slope of time-domain features are calculated over sliding windows. In addition, the FFT analysis is adopted to extract frequency-domain features of the aggregated data, and then energy and correlation of acceleration data are calculated. Child activities are classified into 11 daily activities which are wiggling, rolling, standing still, standing up, sitting down, walking, toddling, crawling, climbing up, climbing down, and stopping. The overall accuracy of activity recognition was 98.43% using only a single-wearable triaxial accelerometer sensor and a barometric pressure sensor with a support vector machine.
引用
收藏
页码:420 / 426
页数:7
相关论文
共 22 条
[1]   Physical activity monitoring based on accelerometry: validation and comparison with video observation [J].
Aminian, K ;
Robert, P ;
Buchser, EE ;
Rutschmann, B ;
Hayoz, D ;
Depairon, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (03) :304-308
[2]  
[Anonymous], 11 C UNC ART INT
[3]  
[Anonymous], 1992, PROGRAMS MACHINE LEA
[4]  
[Anonymous], 2005, AAAI
[5]   Sensor Positioning for Activity Recognition Using Wearable Accelerometers [J].
Atallah, Louis ;
Lo, Benny ;
King, Rachel ;
Yang, Guang-Zhong .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2011, 5 (04) :320-329
[6]  
Baas B.M., 1999, An approach to low-power, high-performance, fast Fourier Transform processor design
[7]   Activity recognition from user-annotated acceleration data [J].
Bao, L ;
Intille, SS .
PERVASIVE COMPUTING, PROCEEDINGS, 2004, 3001 :1-17
[8]  
Bonomi AG, 2011, PHILIPS RES BOOK SER, V12, P41, DOI 10.1007/978-90-481-3258-4_3
[9]  
Boughorbel S., 2010, SER MB 10, P38, DOI DOI 10.1145/1931344.1931382
[10]  
Brooks RR, 1998, Multi-sensor fusion: fundamentals and applications with software