Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading

被引:0
|
作者
Alan, Raif [1 ]
Marakoglu, Ismail [2 ]
Haliloglu, Seyfullah [3 ]
机构
[1] Necmettin Erbakan Univ, Fac Dent, Dept Periodontol, TR-42050 Konya, Turkey
[2] Selcuk Univ, Fac Dent, Dept Periodontol, Konya, Turkey
[3] Selcuk Univ, Fac Dent, Dept Biochem, Konya, Turkey
关键词
Alveolar bone loss; Cathepsin K; Dental implants; Osteoprotegerin; RANK ligand; BONE LOSS; CLINICAL-EVALUATION; RISK-FACTORS; PERIODONTITIS; SURVIVAL; DISEASES; CONSENSUS; DIAMETER; FAILURE; HEALTH;
D O I
10.5051/jpis.2015.45.5.169
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and pen-implant crevicular fluid (PICF) levels of cathepsin-K (CTSK), RANK ligand (RANKL), and osteoprotegerin (UPS), after prosthodontic loading. Methods: A total of 78 non-submerged implants (Euroteknika, Aesthetica(+2), Sallanches, France) were installed in 30 subjects (13 male, 17 female; range, 26-62 years) who visited the clinic of the Periodontology Department Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the pen-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and UPS levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. Results: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG:sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. Conclusions: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 9 条
  • [1] Evaluation of gingival crevicular fluid and peri-implant crevicular fluid levels of sclerostin, TWEAK, RANKL and OPG
    Yakar, Nil
    Guncu, Guliz N.
    Akman, Abdullah C.
    Pinar, Asli
    Karabulut, Erdem
    Nohutcu, Rahime M.
    CYTOKINE, 2019, 113 : 433 - 439
  • [2] Comparison of RANKL and OPG levels in peri-implant crevicular fluid between healthy and diseased peri-implant tissues. A systematic review and meta-analysis
    Theodoridis, C.
    Doulkeridou, C.
    Menexes, G.
    Vouros, I
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (01) : 823 - 836
  • [3] Comparison of RANKL and OPG levels in peri-implant crevicular fluid between healthy and diseased peri-implant tissues. A systematic review and meta-analysis
    C. Theodoridis
    C. Doulkeridou
    G. Menexes
    I. Vouros
    Clinical Oral Investigations, 2022, 26 : 823 - 836
  • [4] The determination of pH of peri-implant crevicular fluid around one-piece and two-piece dental implants: A pilot study
    Karpavicius, Dainius
    Stasikelyte, Morta
    Baseviciene, Nomeda
    Sakalauskaite, Urte
    Ratkute, Saule
    Razukevicius, Dainius
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2019, 5 (03): : 236 - 242
  • [5] Effects of smoking on the bone alkaline phosphatase in peri-implant crevicular fluid and implant stability quotient around implants before loading
    Tuter, Gulay
    Yildirim, Arzu Zeynep
    Duman, Ayse Nurcan
    Aliyev, Behruz
    Atak-Yucel, Aysegul
    Oruklu, Nihan
    Kivrak, Elifcan
    ODONTOLOGY, 2022, 110 (03) : 596 - 604
  • [6] Effects of smoking on the bone alkaline phosphatase in peri-implant crevicular fluid and implant stability quotient around implants before loading
    Gulay Tuter
    Arzu Zeynep Yildirim
    Ayse Nurcan Duman
    Behruz Aliyev
    Aysegul Atak-Yucel
    Nihan Oruklu
    Elifcan Kivrak
    Odontology, 2022, 110 : 596 - 604
  • [7] Levels of Osteoclastogenesis-Related Factors in the Peri-Implant Crevicular Fluid and Clinical Parameters of Immediately Loaded Implants in Patients with Osteopenia: A Short-Term Report
    Onuma, Tatiana
    Aquiar, Kelly
    Duarte, Poliana Mendes
    Feres, Magda
    Giro, Gabriela
    Coelho, Paulo G.
    Cassoni, Alessandra
    Shibli, Jamil Awad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (06) : 1431 - 1436
  • [8] Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study
    Elfadaly, Lamiaa Said
    Khairallah, Lamiaa Sayed
    Al Agroudy, Mona Atteya
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2017, 3
  • [9] Changes of Radiographic Trabecular Bone Density and Peri-Implant Marginal Bone Vertical Dimensions Around Non-Submerged Dental Implants with a Laser-Microtextured Collar after 5 Years of Functional Loading
    Guarnieri, Renzo
    Miccoli, Gabriele
    Seracchiani, Marco
    D'Angelo, Maurilio
    Di Nardo, Dario
    Testarelli, Luca
    OPEN DENTISTRY JOURNAL, 2020, 14 : 226 - 234