摘要
The present paper presents a numerical analysis of the difference in comfort level inside a room of a residential building when roof top turbine ventilator is installed. This analysis simulates various comfort factors which include the indoor air movement, room temperature, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD). Various test cases of ventilator exhaust rate were examined. The results showed that general comfort satisfying international standards in building can be achieved. This study also presents a qualitative and quantitative study of indoor air temperature and overall indoor air flow pattern. A promising conclusion that can be drawn from this study is that wind driven ventilators can play an important role in the design of a cost effective and energy efficient ventilation system inside a building. (C) 2012 The Authors. Published by Elsevier Ltd. Selection and/or peer-review under responsibility of the International Energy Foundation
引用
收藏
页码:124 / 134
页数:11
相关论文
共 50 条
  • [21] Evaluation of Indoor Air Quality in Day Care Centres for the Elderly
    Pinto, Mario
    Rebelo, Andreia
    Santos, Joana
    Silva, Manuela Vieira
    SHO 2012: INTERNATIONAL SYMPOSIUM ON OCCUPATIONAL SAFETY AND HYGIENE, 2012, : 466 - 470
  • [22] Evaluation of health benefits for improving indoor air quality in workplace
    Chau, C. K.
    Hui, W. K.
    Tse, M. S.
    ENVIRONMENT INTERNATIONAL, 2007, 33 (02) : 186 - 198
  • [23] Evaluation of indoor air quality on the basis of measurements of VOC concentrations
    Zabiegala, B
    Przyk, E
    Przyjazny, A
    Namiesnik, J
    CHEMIA ANALITYCZNA, 2000, 45 (01): : 11 - 26
  • [24] New and innovative wind catcher designs to improve indoor air quality in buildings
    Alwetaishi M.
    Gadi M.
    Energy and Built Environment, 2021, 2 (04): : 337 - 344
  • [25] Evaluation of environmental and indoor air quality in new and renovated social housing units in Chile
    Flamant, Gilles
    Bustamante, Waldo
    Janssens, Arnold
    Laverge, Jelle
    Jorquera, Hector
    BUILDING AND ENVIRONMENT, 2025, 274
  • [26] Evaluation of the Effectiveness of Common Indoor Plants in Improving the Indoor Air Quality of Studio Apartments
    Sharma, Shambhavi
    Bakht, Ahtesham
    Jahanzaib, Muhammad
    Lee, Hyunsoo
    Park, Duckshin
    ATMOSPHERE, 2022, 13 (11)
  • [27] Study on indoor air quality evaluation index based on comfort evaluation experiment
    Zhu, Chihui
    Li, Nianping
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2246 - 2253
  • [28] Performance by Design: Supporting Decisions around Indoor Air Quality in Offices
    Snow, Stephen
    Oakley, Michael
    Schraefel, M. C.
    PROCEEDINGS OF THE 2019 ACM DESIGNING INTERACTIVE SYSTEMS CONFERENCE (DIS 2019), 2019, : 99 - 111
  • [29] Numerical investigation of indoor air quality in a floor heated room with different air change rates
    Mutlu, Mustafa
    BUILDING SIMULATION, 2020, 13 (05) : 1063 - 1075
  • [30] Indoor air quality of urban public transportation stations in China: Based on air quality evaluation indexes
    Fan, Lin
    Han, Xu
    Li, Li
    Liu, Hang
    Ge, Tanxi
    Wang, Xinqi
    Wang, Qin
    Du, Hang
    Su, Liqin
    Yao, Xiaoyuan
    Wang, Xianliang
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 349