Long-term follow-up of transvenous defibrillation leads - High incidence of fracture in coaxial polyurethane lead

被引:18
作者
Kitamura, S
Satomi, K
Kurita, T
Shimizu, W
Suyama, K
Aihara, N
Niwaya, K
Kobayashi, J
Kamakura, S
机构
[1] Natl Cardiovasc Ctr, Dept Cardiovasc Med, Suita, Osaka 5658565, Japan
[2] Natl Cardiovasc Ctr, Dept Cardiovasc Surg, Suita, Osaka 5658565, Japan
关键词
follow-up; implantable cardioverter-defibrillator; lead failure; polyurethane;
D O I
10.1253/circj.70.273
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background As a result of longer follow-up after implantation of cardioverter defibrillators (ICD), fatigue of the leads has become a concern. The aim of this study was to determine the incidence and clinical presentation of ICD lead failures. Methods and Results The Study Population consisted of 241 patients with 249 ICD leads Who underwent implantation of an ICD with a transvenous lead system. After device implantation, the patients were routinely followed up every 4 months. Five lead failures (2.0%) Occurred as an oversensing of artifact during the follow-up period (2.6 +/- 2.1 years); 4 of those 5 patients received inappropriate shocks and I case of lead failure was identified in a patient with frequent episodes of non-sustained ventricular fibrillation. In particular, the right ventricular polyurethane transvenous lead in the Medtronic model 6936 failed in 4 (13%) of 31 cases. Percutaneous lead extraction was not available in all cases, so an additional ICD lead was inserted through the same site of the subclavian vein. Conclusions Lead failures may occur 5 years after ICD implantation and polyurethane leads have an especially high incidence of failure. However, there were no follow-up parameters observed that predicted lead failures.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 50 条
  • [1] Transvenous defibrillation leads: High incidence of failure during long-term follow-up
    Dorwarth, U
    Frey, B
    Dugas, M
    Matis, T
    Fiek, M
    Schmoeckel, M
    Remp, T
    Durchlaub, I
    Gerth, A
    Steinbeck, G
    Hoffmann, E
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (01) : 38 - 43
  • [2] Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study
    Elgaard, Anders Fyhn
    Johansen, Jens Brock
    Nielsen, Jens Cosedis
    Gerdes, Christian
    Riahi, Sam
    Philbert, Berit Thornvig
    Haarbo, Jens
    Melchior, Thomas Maria
    Larsen, Jacob Moesgaard
    EUROPACE, 2020, 22 (07): : 1097 - 1102
  • [3] Defibrillation efficacy testing: Long-term follow-up and mortality
    Theuns, DAMJ
    Szili-Torok, T
    Jordaens, LJ
    EUROPACE, 2005, 7 (06): : 509 - 515
  • [4] Long-Term Follow-Up of Patients with Relatively High Effective Defibrillation Threshold during Cardioverter Defibrillator Implantation with Endocardial Leads
    Rosenheck, Shimon
    Sharon, Zehava
    Weiss, Alexey
    CARDIOLOGY, 2009, 112 (02) : 107 - 113
  • [5] Long-term structural failure of coaxial polyurethane implantable cardioverter defibrillator leads
    Hauser, RG
    Cannom, D
    Hayes, DL
    Parsonnet, V
    Hayes, J
    Ratliff, N
    Tyers, GFO
    Epstein, AE
    Vlay, SC
    Furman, S
    Gross, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (06): : 879 - 882
  • [6] LONG-TERM FOLLOW-UP OF PACEMAKER LEAD SYSTEMS - ESTABLISHMENT OF STANDARDS OF QUALITY
    FURMAN, S
    BENEDEK, ZM
    ANDREWS, CA
    GROSS, JN
    RITACCO, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (02): : 271 - 285
  • [7] LONG-TERM FOLLOW-UP OF PATIENTS WITH SINGLE-LEAD VDD STIMULATION
    FOLINO, AF
    BUJA, G
    RUZZA, L
    NAVA, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1854 - 1858
  • [8] Premature thelarche: A long-term follow-up
    Verrotti, A
    Ferrari, M
    Morgese, G
    Chiarelli, F
    GYNECOLOGICAL ENDOCRINOLOGY, 1996, 10 (04) : 241 - 247
  • [9] Long-term follow-up of children with retinoblastoma
    Nahum, MP
    Gdal-On, M
    Kuten, A
    Herzl, G
    Horovitz, Y
    Ben Arush, MW
    PEDIATRIC HEMATOLOGY AND ONCOLOGY, 2001, 18 (03) : 173 - 179
  • [10] INCIDENCE OF ICD LEAD RELATED COMPLICATIONS DURING LONG-TERM FOLLOW-UP - COMPARISON OF EPICARDIAL AND ENDOCARDIAL ELECTRODE SYSTEMS
    KORTE, T
    JUNG, W
    SPEHL, S
    WOLPERT, C
    MOOSDORF, R
    MANZ, M
    LUDERITZ, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (11): : 2053 - 2061