Occupational exposure to sevoflurane, halothane and nitrous oxide during paediatric anaesthesia - Waste gas exposure during paediatric anaesthesia

被引:58
|
作者
Hoerauf, K
Funk, W
Harth, M
Hobbhahn, J
机构
[1] University Hospital, Department of Anaesthesiology, 1090 Vienna
关键词
anaesthetics; volatile; sevoflurane; halothane; trace concentrations anaesthetics; gases nitrous oxide; trace concentrations; anaesthesia; paediatric;
D O I
10.1111/j.1365-2044.1997.070-az0061.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We report the findings of a study on exposure of operating room staff to sevoflurane, halothane and nitrous oxide during induction and maintenance of anaesthesia in children. Concentrations of anaesthetic agents in the operating theatre were measured directly by highly sensitive, photoacoustic infrared spectrometer during 20 anaesthetics. Samples were taken from the breathing zones of the anaesthetist and the circulating nurse. The operating theatre was of modern design with an air conditioning system providing 20 changes of air each hour. The threshold values of. 100 ppm N2O, 50 ppm isoflurane and 10 ppm halothane recommended by the United Kingdom Committee for Occupational Safety and Health (COSH) were exceeded in several cases for a short time during mask induction. After tracheal intubation, trace concentrations of sevoflurane, halothane and N2O were mostly under the recommended levels and comparable to levels measured during adult anaesthesia.
引用
收藏
页码:215 / 219
页数:5
相关论文
共 50 条
  • [41] The bispectral index during recovery from halothane and sevoflurane anaesthesia in horses
    Beldao, Eliseo
    Blissitt, Karen J.
    Duncan, Juliet C.
    Laredo, Francisco G.
    Escobar Gil de Montes, Mayte
    Clutton, R. Eddie
    VETERINARY ANAESTHESIA AND ANALGESIA, 2010, 37 (01) : 25 - 34
  • [42] Surgeons' exposure to sevoflurane during paediatric adenoidectomy: a comparison of three airway devices
    Herzog-Niescery, J.
    Gude, P.
    Gahlen, F.
    Seipp, H. -M.
    Bartz, H.
    Botteck, N. M.
    Bellgardt, M.
    Dazert, S.
    Weber, T. P.
    Vogelsang, H.
    ANAESTHESIA, 2016, 71 (08) : 915 - 920
  • [43] Effect of nitrous oxide on spectral entropy during sevoflurane anaesthesia at an altitude of 1 400 metres
    Spijkerman, S.
    Smith, F. J.
    Becker, P. J.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2007, 13 (02) : 46 - 46
  • [44] Isoflurane waste gas exposure during general anaesthesia: The laryngeal mask compared with tracheal intubation
    Hoerauf, KH
    Koller, C
    Jakob, W
    Taeger, L
    Hobbhahn, J
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (02) : 189 - 193
  • [45] HAEMODYNAMIC EFFECTS OF BETA-RECEPTOR BLOCKING DRUGS DURING NITROUS OXIDE/HALOTHANE ANAESTHESIA
    STEPHEN, GW
    DAVIE, IT
    SCOTT, DB
    BRITISH JOURNAL OF ANAESTHESIA, 1971, 43 (04) : 320 - &
  • [46] Changes in heart rate variability during anaesthesia induction using sevoflurane or isoflurane with nitrous oxide
    Nishiyama, Tomoki
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2016, 48 (04) : 248 - 251
  • [47] The use of remifentanil for intubation in paediatric patients during sevoflurane anaesthesia guided by Bispectral Index (BIS) monitoring
    Weber, F
    Füssel, U
    Gruber, M
    Hobbhahn, J
    ANAESTHESIA, 2003, 58 (08) : 749 - 755
  • [48] PULMONARY GAS EXCHANGE DURING INDUCTION OF ANAESTHESIA WITH NITROUS OXIDE IN SEATED SUBJECTS
    SHAH, J
    JONES, JG
    GALVIN, J
    TOMLIN, PJ
    BRITISH JOURNAL OF ANAESTHESIA, 1971, 43 (11) : 1013 - &
  • [49] Environmental monitoring of nitrous oxide during dental anaesthesia
    K A Henderson
    I P Matthews
    British Dental Journal, 2000, 188 : 617 - 619
  • [50] Environmental monitoring of nitrous oxide during dental anaesthesia
    Henderson, KA
    Matthews, IP
    BRITISH DENTAL JOURNAL, 2000, 188 (11) : 617 - 619