Quantification of myocardial blood flow using 13N-ammonia and PET:: Comparison of tracer models

被引:0
作者
Choi, Y
Huang, SC
Hawkins, RA
Kim, JY
Kim, BT
Hoh, CK
Chen, K
Phelps, ME
Schelbert, HR
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Nucl Med, Samsung Med Ctr, Seoul 135230, South Korea
[2] Univ Calif Los Angeles, Sch Med, Div Nucl Med & Biophys, Dept Mol & Med Pharmacol, Los Angeles, CA USA
关键词
myocardial blood flow; N-13-ammonia; PET; tracer kinetic methods;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several tracer kinetic methods have been proposed for quantification of regional myocardia[ blood flow (MBF) with N-13-ammonia and PET. Merits and limitations specific to each approach, however, generally are not clear, because they have not been evaluated in the same experimental environment. Therefore, we compared six different commonly used methods (11 modifications) to characterize the accuracy of each approach. The methods included the two-parameter model (method 1), the modified two-parameter model (method 2), the four-parameter model (method 3), the graphical analysis (method 4), the first-pass extraction method (method 5) and the dose uptake index (DUI; method 6). Methods: Eleven studies in four dogs, 16 studies in eight healthy human volunteers and 14 studies in seven patients were performed using N-13-ammonia and PET. MBF in dogs was varied with dipyridamole and coronary occlusions and was measured independently and simultaneously with microspheres. Volunteers and patients were studied at baseline and after dipyridamole. MBF and DUI were estimated using a time-activity curve (Q(i)[t]) derived from dynamic images and regions of interest (ROIs) and using the six methods. DUI was defined as Q(i)(t = 2 min) x weight/dose. Results: MBF estimated by methods 1-5 correlated well with microsphere MBF in dogs. MBF estimates by method 1 correlated well with those by methods 2, 4 and 5 and to a lesser degree with those by method 3 in both dog and human studies. DUI correlated poorly with MBF by microspheres and by methods 1-5 in both dog and human studies. MBF estimates by method 3 showed larger dispersion (SD/mean flow) and higher sensitivity to metabolites correction in arterial blood than those by methods 1, 2, 4 and 5. Conclusion: MBF can be measured accurately using N-13-ammonia PET and tracer kinetic methods. DUI is a poor indicator of MBF values. The results indicate that preference should be given to the two-parameter model, incorporating geometrical ROI representation (method 2) among the compartment models, and to the graphical analysis (method 4) among the noncompartmental approaches.
引用
收藏
页码:1045 / 1055
页数:11
相关论文
共 24 条
  • [1] BELLINA CR, 1990, J NUCL MED, V31, P1335
  • [2] COMPARISON OF MAXIMAL MYOCARDIAL BLOOD-FLOW DURING ADENOSINE INFUSION WITH THAT OF INTRAVENOUS DIPYRIDAMOLE IN NORMAL MEN
    CHAN, SY
    BRUNKEN, RC
    CZERNIN, J
    PORENTA, G
    KUHLE, W
    KRIVOKAPICH, J
    PHELPS, ME
    SCHELBERT, HR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) : 979 - 985
  • [3] CHOI Y, 1993, J NUCL MED, V34, P488
  • [4] CHOI Y, 1991, J NUCL MED, V32, P733
  • [5] Estimation of myocardial blood flow for longitudinal studies with N-13-labeled ammonia and positron emission tomography
    DeGrado, TR
    Hanson, MW
    Turkington, TG
    Delong, DM
    Brezinski, DA
    Vallee, JP
    Hedlund, LW
    Zhang, J
    Cobb, F
    Sullivan, MJ
    Coleman, RE
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1996, 3 (06) : 494 - 507
  • [6] ASSESSMENT OF CORONARY-ARTERY DISEASE SEVERITY BY POSITRON EMISSION TOMOGRAPHY - COMPARISON WITH QUANTITATIVE ARTERIOGRAPHY IN 193 PATIENTS
    DEMER, LL
    GOULD, KL
    GOLDSTEIN, RA
    KIRKEEIDE, RL
    MULLANI, NA
    SMALLING, RW
    NISHIKAWA, A
    MERHIGE, ME
    [J]. CIRCULATION, 1989, 79 (04) : 825 - 835
  • [7] GAMBHIR SS, 1989, J NUCL MED, V30, P359
  • [8] GAMBHIR SS, 1990, QUANTIFICATION PHYSI
  • [9] Quantitative PET measurements of regional myocardial blood flow: Observations in humans with ischemic heart disease
    Gewirtz, H
    Skopicki, HA
    Abraham, SA
    Castano, H
    Dinsmore, RE
    Alpert, NM
    Fischman, AJ
    [J]. CARDIOLOGY, 1997, 88 (01) : 62 - 70
  • [10] BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES
    HEYMANN, MA
    PAYNE, BD
    HOFFMAN, JIE
    RUDOLPH, AM
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) : 55 - 79