Development and validation of a rapid and sensitive liquid chromatography-tandem mass spectrometry method for benvitimod quantification in human plasma

被引:6
|
作者
Zhao, Libo [1 ]
Zhu, Baoying [2 ]
Chen, Xin [1 ]
Chen, Genghui [3 ]
Chen, Haibo [4 ]
Li, Yuzhen [1 ]
Jing, Shan [1 ]
Fang, Yi [1 ]
机构
[1] Peking Univ Peoples Hosp, Dept Pharm, Beijing 100044, Peoples R China
[2] Guiyang Med Coll, Guiyang 550004, Peoples R China
[3] Celestial Pharmaceut Co Ltd, Shenzhen 518057, Peoples R China
[4] Xuzhou Med Coll, Xuzhou 221004, Peoples R China
关键词
Benvitimod; LC/ESI/MS/MS; Human plasma; Pharmacokinetics; PERFORMANCE;
D O I
10.1016/j.jchromb.2011.12.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benvitimod is a newly synthesized non-steroid small molecule being developed as a candidate drug for the treatment of inflammatory skin diseases. Here a rapid, sensitive and specific high performance liquid chromatography-tandem mass spectrometry (LC/ESI/MS/MS) method was developed for the determination of benvitimod in human plasma. The samples were alkalified with disodium tetraborate firstly, and then extracted by methyl tert-butyl ether. Fluorophenyl-benvitimod was used as internal standard (IS.). Chromatographic separation was performed on an Ultra C-18 column (150 mm x 2.1 mm, 5.0 mu m). The mixed mobile phase delivered at 300 mu l/min was CH3CN/H2O, 76.65:23.35 (v/v), containing 0.2 mmol/L NH4COOH. Detection and quantitation was performed by electrospray ionization (ESI) and multiple reaction monitoring (MRM) in the negative ion mode. The most intense [M-H](-) MRM transition of benvitimod at m/z 253.1 -> 211.0 was used for benvitimod quantitation and the transition at m/z 270.9 -> 229.2 was used to monitor I.S. The calibration curve was linear within the concentration range of 0.1-10.0 ng/mL (r > 0.99). The lower limit of quantification (LLOQ) was 0.1 ng/mL. The extraction recovery was above 80%. The accuracy expressed as relative error (RE) was less than 1.03%. The intra- and inter-day precisions were less than 11.81%. The freeze-thaw stability was also investigated and it was found that both benvitimod and the 1.5. were quite stable. This method is especially useful for the pharmacokinetic study of benvitimod. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [41] Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Cangemi, Giuliana
    Barco, Sebastiano
    Bandettini, Roberto
    Castagnola, Elio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (06) : 1795 - 1798
  • [42] Sensitive quantification of diphemanil methyl sulphate in human plasma by liquid chromatography-tandem mass spectrometry
    Do, B.
    Goulay-Dufay, S.
    Le Hoang, M. D.
    Adoui, N.
    Graffard, H.
    Guyon, F.
    Pradeau, D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01): : 104 - 108
  • [43] Highly sensitive liquid chromatography-tandem mass spectrometry method for quantification of TAK-448 in human plasma
    Kuze, Yoji
    Jinno, Fumihiro
    Kondo, Takahiro
    Asahi, Satoru
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 83 : 75 - 81
  • [44] Rapid and sensitive liquid chromatography-tandem mass spectrometry: Assay development, validation and application to a human pharmacokinetic study
    Song, Min
    Wang, Li
    Zhao, Hua
    Hang, Taijun
    Wen, Aidong
    Yang, Lin
    Jia, Lee
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 515 - 521
  • [45] Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Ciprofibrate From Human Plasma
    Shah, Dimal
    Mavani, Dilip
    Patel, Harilal
    Baldania, Sunil
    Bhatt, Kashyap
    Chhalotiya, Usmangani
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (02) : 219 - 225
  • [46] Bioanalytical method development, validation and quantification of flupirtine maleate in rat plasma by liquid chromatography-tandem mass spectrometry
    Kandasamy, Karthikeyan
    Gowdra, Vasantharaju Surenahalli
    Nammalvar, Hariprabhu
    Govindarajan, Arul Kumaran Kottur S.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (12): : 693 - 699
  • [47] Development and validation of bioanalytical method for quantification of cycloserine in human plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study
    Dodda, Sireesha
    Makula, Ajitha
    Kandhagatla, Raj Narayana
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (08)
  • [48] Rapid ultraperformance liquid chromatography-tandem mass spectrometry method for quantification of oxcarbazepine and its metabolite in human plasma
    Bhatt, Mitesh
    Shaha, Sanjay
    Shivprakash
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (07) : 751 - 759
  • [49] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of clarithromycin in human plasma
    van Rooyen, GF
    Smit, MJ
    de Jager, AD
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 768 (02): : 223 - 229
  • [50] Rapid quantification of the metabolite of valacyclovir hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry
    Yuan Tian1
    2. Center for Instrumental Analysis
    3. Department of Clinical Pharmacology
    Journal of Pharmaceutical Analysis, 2010, 22 (02) : 83 - 90