Study of automotive radiator cooling system for dense-array concentration photovoltaic system

被引:23
作者
Chong, Kok-Keong [1 ]
Tan, Woei-Chong [1 ]
机构
[1] Univ Tunku Abdul Rahman, Fac Sci & Engn, Kuala Lumpur 53300, Malaysia
关键词
Automotive radiator; Concentrator photovoltaic; High concentration solar energy; Cooling system; Non-imaging planar concentrator; Heat rejection; NONIMAGING PLANAR CONCENTRATOR; DESIGN; CELLS; FORMULA;
D O I
10.1016/j.solener.2012.05.033
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An automotive radiator is proposed for the heat rejection of the dense-array concentrator photovoltaic (CPV) system. Theoretical modeling on the integration of automotive radiator into the cooling system with a specially designed cooling block has been carried out in details. To verify the feasibility of new proposal, the automotive radiator cooling system has been constructed and tested to effectively lower down the temperature of CPV module in a non-imaging planar concentrator prototype with total reflective area of 4.16 m(2) at solar concentration ratio of 377 suns. During the on-site measurement, it has been observed that the conversion efficiency of CPV module has successfully improved from 22.39% to 26.85% when the CPV cell temperature is reduced from 59.4 degrees C to 37.1 degrees C. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2632 / 2643
页数:12
相关论文
共 27 条
[1]  
Aes Lars G., 2008, US Patent, Patent No. [2008/0006320 A1, 20080006320]
[2]  
[Anonymous], 1989, SOLOR CELLS OPTICS P
[3]   A simple-passive cooling structure and its heat analysis for 500 X concentrator PV module [J].
Araki, K ;
Uozumi, H ;
Yamaguchi, M .
CONFERENCE RECORD OF THE TWENTY-NINTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE 2002, 2002, :1568-1571
[4]   Optical Characterization of Nonimaging Planar Concentrator for the Application in Concentrator Photovoltaic System [J].
Chong, K. K. ;
Wong, C. W. ;
Siaw, F. L. ;
Yew, T. K. .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (01) :0110111-0110119
[5]   Design and construction of non-imaging planar concentrator for concentrator photovoltaic system [J].
Chong, K. K. ;
Siaw, F. L. ;
Wong, C. W. ;
Wong, G. S. .
RENEWABLE ENERGY, 2009, 34 (05) :1364-1370
[6]   General formula for on-axis sun-tracking system and its application in improving tracking accuracy of solar collector [J].
Chong, K. K. ;
Wong, C. W. .
SOLAR ENERGY, 2009, 83 (03) :298-305
[7]  
Chong K. K., 2011, Int. J. Energy Eng, V1, P25, DOI [10.5923/j.ijee.20110101.05, DOI 10.5923/J.IJEE.20110101.05]
[8]   Integration of an On-Axis General Sun-Tracking Formula in the Algorithm of an Open-Loop Sun-Tracking System [J].
Chong, Kok-Keong ;
Wong, Chee-Woon ;
Siaw, Fei-Lu ;
Yew, Tiong-Keat ;
Ng, See-Seng ;
Liang, Meng-Suan ;
Lim, Yun-Seng ;
Lau, Sing-Liong .
SENSORS, 2009, 9 (10) :7849-7865
[9]   Thermal analysis and test for single concentrator solar cells [J].
Cui Min ;
Chen Nuofu ;
Yang Xiaoli ;
Wang Yu ;
Bai Yiming ;
Zhang Xingwang .
JOURNAL OF SEMICONDUCTORS, 2009, 30 (04) :044011-1
[10]   DESIGN CONSIDERATIONS FOR HIGH-INTENSITY SOLAR-CELLS [J].
DALAL, VL ;
MOORE, AR .
JOURNAL OF APPLIED PHYSICS, 1977, 48 (03) :1244-1251