Rapid method for the quantification of 13 sulphonamides in milk by conventional high-performance liquid chromatography with diode array ultraviolet detection using a column packed with core-shell particles

被引:20
作者
Armentano, Antonio [1 ]
Summa, Simona [1 ]
Lo Magro, Sonia [1 ]
Palermo, Carmen [2 ]
Nardiello, Donatella [2 ]
Centonze, Diego [2 ]
Muscarella, Marilena [1 ]
机构
[1] Ist Zooprofilattico Sperimentale Puglia & Basilic, Via Manfredonia 20, I-71121 Foggia, Italy
[2] Univ Foggia, Dipartimento Sci Agr Alimenti & Ambient, Via Napoli 25, Foggia, Italy
关键词
Sulphonamides; HPLC; Core-shell particles; Uv-dad; Milk; TANDEM MASS-SPECTROMETRY; SOLID-PHASE EXTRACTION; BOVINE-MILK; CONFIRMATORY METHOD; VALIDATION; RESIDUES; SEPARATION; KINETEX-C-18; MEAT;
D O I
10.1016/j.chroma.2017.11.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present study, a column packed with core-shell particles was used for the separation and the quantification of 13 sulphonamides in milk by conventional high-performance liquid chromatography coupled with diode array ultraviolet detection (HPLC/UV-DAD). Preliminary experiments were carried out to investigate selectivity of different stationary phases. Best results were achieved using a C-18 column packed with 2.6 pm core-shell particles (diameter 4.6 mm, length 75 mm). A binary gradient elution based on acetate buffer solution at pH 4.50 and a mixture of methanol acetonitrile 50:50 (v/v) was employed at the flow rate of 1.2 mL min(-1) with an injection volume of 6 mu L. These chromatographic conditions allowed the efficient separation of 13 sulphonamides in about 8 min. To evaluate the suitability of the method for official control analysis, the most important validation parameters were investigated according to the European Decision 657/2002/EC as established for analysis of drug residues in food. Sulphonamides were recovered from milk samples by a simple and quick preparation procedure consisting of an extraction step with chloroform/acetone and a purification step with n-hexane. Mean recoveries from raw milk ranged between 55% and 86% at the Maximum Residual Limit of 100 mu g kg(-1), and RSDs% resulted lower than Thompson and Horwitz RSD% reference values for all sulphonamides. The LOQ value (2.7-15 mu g kg(-1)) was low enough to satisfy legal limits suggested by European Regulation 37/2010/EC. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 37 条
[1]  
[Anonymous], 2002, 99332 AOAC
[2]  
[Anonymous], 2016, PIAN NAZ RES 2016 P
[3]   Core-shell in liquid chromatography: application for determining sulphonamides in feed and meat using conventional chromatographic systems [J].
Armentano, Antonio ;
Summa, Simona ;
Lo Magro, Sonia ;
D'Antini, Pasquale ;
Palermo, Carmen ;
Muscarella, Marilena .
ITALIAN JOURNAL OF FOOD SAFETY, 2016, 5 (04) :245-248
[4]   Separation of 9 Sulfonamide Drugs in aparts per thousand4 Min by Ultra-High Performance Supercritical Fluid Chromatography (UHPSFC): with a Feasibility Study for Detection in Milk [J].
Berger, Terry A. ;
Berger, Blair K. .
CHROMATOGRAPHIA, 2013, 76 (23-24) :1631-1639
[5]   Confirmatory analysis of sulfonamide antibacterials in bovine liver and kidney: extraction with hot water and liquid chromatography coupled to a single- or triple-quadrupole mass spectrometer [J].
Bogialli, S ;
Curini, R ;
Di Corcia, A ;
Nazzari, M ;
Sergi, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (11) :1146-1156
[6]   Analysis of Sulfonamides in Animal Feeds by Liquid Chromatography with Fluorescence Detection [J].
Borras, Silvia ;
Companyo, Ramon ;
Guiteras, Jacinto .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (10) :5240-5247
[7]   Relationship between the particle size distribution of commercial fully porous and superficially porous high-performance liquid chromatography column packings and their chromatographic performance [J].
Cabooter, D. ;
Fanigliulo, A. ;
Bellazzi, G. ;
Allieri, B. ;
Rottigni, A. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (45) :7074-7081
[8]   Simultaneous determination of 24 sulfonamide residues in meat by ultra-performance liquid chromatography tandem mass spectrometry [J].
Cai, Zengxuan ;
Zhang, Yu ;
Pan, Hongfeng ;
Tie, Xiaowei ;
Ren, Yiping .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1200 (02) :144-155
[9]   A confirmatory method for the determination of tetracyclines in muscle using high-performance liquid chromatography with diode-array detection [J].
Cristofani, Elisa ;
Antonini, Chiara ;
Tovo, Gloria ;
Fioroni, Laura ;
Piersanti, Arianna ;
Galarini, Roberta .
ANALYTICA CHIMICA ACTA, 2009, 637 (1-2) :40-46
[10]   Nano-liquid chromatography coupled with mass spectrometry: Separation of sulfonamides employing non-porous core-shell particles [J].
D'Orazio, Giovanni ;
Rocchi, Silvia ;
Fanali, Salvatore .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 :277-285