Power Quality Improvement in Hybrid Power System using D-STATCOM

被引:0
作者
Parija, Bhagyashree [1 ]
Behera, Santi [2 ]
Pattanayak, Ruturaj [1 ]
Behera, Sasmita [2 ]
机构
[1] Veer Surendra Sai Univ Technol, Dept Elect Engn, Burla, India
[2] Veer Surendra Sai Univ Technol, Dept Elect & Elect Engn, Burla, India
来源
PROCEEDINGS OF THE 2019 3RD INTERNATIONAL CONFERENCE ON COMPUTING METHODOLOGIES AND COMMUNICATION (ICCMC 2019) | 2019年
关键词
Reactive Power Compensation (RPC); Total Harmonics Distortion (THD); D-STATCOM; Hybrid system; Distributed Generation(DG); Solar Photo Voltaic (SPV);
D O I
10.1109/iccmc.2019.8819656
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The emanate use of distributed energy sources in electricity grid has created new ultimatum for the utility load as regard to power quality, voltage stabilization and efficient energy utilization. Wind and Solar are considered as the most assuring source of renewable energy. However, the standalone operation of either Photo-voltaic or wind energy system does not offer a very reliable source of electricity production, mainly due to the unpredictability over the availability of the wind and solar irradiance. Thus, an assortment of wind and solar power generation structure can form a very much potential and reliable source of electricity. In this work a hybrid model of wind and Photo-voltaic system has been presented. This kind of system is very beneficial and useful to the remotely located or islanded areas where grid integration is not very economical. However, the interfacing of power electronic devices to DG systems induces very severe power quality problems, such as, harmonic generation and the reactive power compensation that disturbs the power distribution system. In this work, a simulation model of hybrid wind-PV generation system of capacity 750 KW has been presented. The performance of this system with grid connected mode is analyzed. The power quality of the wind-SPV hybrid system has been evaluated by calculating the total harmonics distortion (THD) at different wind speed. Power quality of this hybrid system has been improved by using D-STATCOM.
引用
收藏
页码:564 / 567
页数:4
相关论文
共 12 条
[1]  
Bakare GA, 2005, IEEE POWER ENG SOC, P1916
[2]  
Bogaraj T, INT REV MODELLING SI, V5
[3]  
Gayatri, 2018, RENEWABLE SUSTAINABL
[4]  
Guan D, 2009, 2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, P5019
[5]  
Hingorani N.G., 1999, Understanding FACTS: Concepts and Technology of Flexible Ac Transmission Systems
[6]   The Impact on Power Quality by PWM Converter in Micro-grid [J].
Huang Wei ;
Zhang Jianhua ;
Xie Qinghua ;
Wu Ziping .
2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, :239-+
[7]  
Kandil M. S., 2010, 2010 IEEE International Energy Conference (ENERGYCON 2010), P446, DOI 10.1109/ENERGYCON.2010.5771722
[8]   Microgrid power quality enhancement using a three-phase four-wire grid-interfacing compensator [J].
Li, YW ;
Vilathgamuwa, DM ;
Loh, PC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (06) :1707-1719
[9]   Large Piezoelectric Effect in Pb-Free Ceramics [J].
Liu, Wenfeng ;
Ren, Xiaobing .
PHYSICAL REVIEW LETTERS, 2009, 103 (25)
[10]   Comparison of direct-drive and geared generator concepts for wind turbines [J].
Polinder, Henk ;
van der Pijl, Frank F. A. ;
de Vilder, Gert-Jan ;
Tavner, Peter J. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) :725-733