3D-radiographic analysis does not improve the Neer and AO classifications of proximal humeral fractures

被引:62
作者
Sjödén, GOJ [1 ]
Movin, T
Aspelin, P
Güntner, P
Shalabi, A
机构
[1] Huddinge Univ Hosp, Karolinska Inst, Dept Orthoped, SE-14186 Huddinge, Sweden
[2] Huddinge Univ Hosp, Karolinska Inst, Dept Radiol, SE-14186 Huddinge, Sweden
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1999年 / 70卷 / 04期
关键词
D O I
10.3109/17453679908997818
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Neer and AO fracture classifications for fractures of the proximal humerus have shown poor reproducibility based on plain radiography, We wanted to investigate whether the addition of 3-dimensional (3D) reconstructions would increase the reproducibility of classification. 7 observers independently classified 24 fractures of the proximal humerus using both plain radiographs, CT and 3D and the classification was repeated 2 months later. There was a moderate interobserver agreement when using the Neer classification, but only a fair agreement with the AO classification. The Neer system had a mean kappa value of 0.44 and the AO had a value of 0.32 for the first assessment. In the second assessment, the mean kappa values were 0.49 and 0.34, respectively. Intraobserver reproducibility was fair to substantial agreement for Neer (kappa range 0.27-0.73) and for AO (kappa range 0.29-0.74). In conclusion, the addition of CT and 3D to plain radiographs did not improve the reproducibility of the classifications of Neer and AO of the proximal humerus.
引用
收藏
页码:325 / 328
页数:4
相关论文
共 17 条
[1]   Evaluation of the Neer system of classification of proximal humeral fractures with computerized tomographic scans and plain radiographs [J].
Bernstein, J ;
Adler, LM ;
Blank, JE ;
Dalsey, RM ;
Williams, GR ;
Iannotti, JP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1371-1375
[2]   Taxonomy and treatment - a classification of fracture classifications [J].
Bernstein, J ;
Monaghan, BA ;
Silber, JS ;
DeLong, WG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :706-707
[3]   COMPUTED-TOMOGRAPHY IN TRAUMATOLOGY WITH SPECIAL REGARD TO THE ADVANCES OF 3-DIMENSIONAL DISPLAY [J].
BILLET, FPJ ;
SCHMITT, WGH ;
GAY, B .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1992, 111 (03) :131-137
[4]   NEERS CLASSIFICATION-SYSTEM - A CRITICAL-APPRAISAL [J].
BRIEN, H ;
NOFTALL, F ;
MACMASTER, S ;
CUMMINGS, T ;
LANDELLS, C ;
ROCKWOOD, P .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1995, 38 (02) :257-260
[6]   Fracture classification - A response [J].
Colton, CL .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :708-709
[7]   RAMIFICATIONS OF A POPULATION-MODEL FOR KAPPA AS A COEFFICIENT OF RELIABILITY [J].
KRAEMER, HC .
PSYCHOMETRIKA, 1979, 44 (04) :461-472
[8]   THE NEER CLASSIFICATION OF FRACTURES OF THE PROXIMAL HUMERUS - AN ASSESSMENT OF INTEROBSERVER VARIATION [J].
KRISTIANSEN, B ;
ANDERSEN, ULS ;
OLSEN, CA ;
VARMARKEN, JE .
SKELETAL RADIOLOGY, 1988, 17 (06) :420-422
[9]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]  
Muller M.E., 1990, COMPREHENSIVE CLASSI, P54, DOI [10.1007/978-3-642-61261-9_4, DOI 10.1007/978-3-642-61261-9_4]