High-Resolution Magnetic Resonance Imaging Using Compressed Sensing for Intracranial and Extracranial Arteries: Comparison with Conventional Parallel Imaging

被引:29
|
作者
Suh, Chong Hyun [1 ,2 ]
Jung, Seung Chai [1 ,2 ]
Lee, Ho Beom [1 ,2 ]
Cho, Se Jin [1 ,2 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Asan Med Ctr, Res Inst Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
关键词
Intracranial artery disease; Image quality; Undersampling; Reconstruction method; Signal-to-noise ratio; Contrast-to-noise ratio; Compressed sensing; DIGITAL-SUBTRACTION-ANGIOGRAPHY; VESSEL WALL; BLACK; MRI; DIAGNOSIS;
D O I
10.3348/kjr.2018.0424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare conventional sensitivity encoding (SENSE) to compressed sensing plus SENSE (CS) for high-resolution magnetic resonance imaging (HR-MRI) of intracranial and extracranial arteries. Materials and Methods: HR-MRI was performed in 14 healthy volunteers. Three-dimensional T1-weighted imaging (T1WI) and proton density-weighted imaging (PD) were acquired using CS or SENSE under the same total acceleration factors (AF(t))-5.5, 6.8, and 9.7 for T1WI and 3.2, 4.0, and 5.8 for PD-to achieve reduced scanning times in comparison with the original imaging sequence (SENSE T1WI, AF(t) 3.5; SENSE PD, AF(t) 2.0) using the 3-tesla system. Two neuroradiologists measured signalto-noise ratio (SNR) and contrast-to-noise ratio (CNR), and used visual scoring systems to assess image quality. Acceptable imaging was defined as a visual score >= 2. Repeated measures analysis of variance and Cochran's Q test were performed. Results: CS yielded better image quality and vessel delineation than SENSE in T1WI with AF(t) of 5.5, 6.8, and 9.7, and in PD with AF(t) of 5.8 (p < 0.05). CS T1WI with AF(t) of 5.5 and CS PD with AF(t) of 3.2 and 4.0 did not differ significantly from original imaging (p > 0.05). SNR and CNR in CS were higher than they were in SENSE, but lower than they were in the original images (p < 0.05). CS yielded higher proportions of acceptable imaging than SENSE (CS T1WI with AF(t) of 6.8 and PD with AF(t) of 5.8; p < 0.0167). Conclusion: CS is superior to SENSE, and may be a reliable acceleration method for vessel HR-MRI using AF(t) of 5.5 for T1WI, and 3.2 and 4.0 for PD.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 50 条
  • [1] Parallel Magnetic Resonance Imaging Using Compressed Sensing
    Bilgin, Ali
    Kim, Yookyung
    Lalgudi, Hariharan G.
    Trouard, Theodore P.
    Altbach, Maria I.
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXI, 2008, 7073
  • [2] Compressed Sensing Parallel Magnetic Resonance Imaging
    Ji, Jim X.
    Zhao, Chen
    Lang, Tao
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1671 - 1674
  • [3] Using the Compressed Sensing Technique for Lumbar Vertebrae Imaging: Comparison with Conventional Parallel Imaging
    Gao, Tianyang
    Lu, Zhao
    Wang, Fengzhe
    Zhao, Heng
    Wang, Jiazheng
    Pan, Shinong
    CURRENT MEDICAL IMAGING, 2021, 17 (08) : 1010 - 1017
  • [4] High resolution magnetic resonance imaging using compressed sensing-Sensitivity encoding for patients with suspected neurovascular compression syndrome: Comparison with conventional sense parallel technique
    Cho, S. J.
    Choi, Y. J.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2019, 405
  • [5] High-resolution magnetic resonance imaging of the triangular fibrocartilage complex using compressed sensing sensitivity encoding (SENSE)
    Fujiwara, Hiroki
    Yabuuchi, Hidetake
    Wada, Tatsuhiro
    Kobayashi, Kouji
    Hoshuyama, Toko
    Kamitani, Takeshi
    Ishigami, Kousei
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [6] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF CORONARY-ARTERIES
    PARITOSH, DL
    LI, D
    DHAWALE, PJ
    KAUSHIKKAR, S
    HAACKE, EM
    CIRCULATION, 1995, 92 (08) : 1070 - 1070
  • [7] Intracranial Atherosclerosis: From Microscopy to High-Resolution Magnetic Resonance Imaging
    Yang, Wen-jie
    Wong, Ka-sing
    Chen, Xiang-yan
    JOURNAL OF STROKE, 2017, 19 (03) : 249 - +
  • [8] High-resolution magnetic resonance imaging of acute intracranial artery thrombus
    Zhang, Zong-Mu-Yu
    Si, Qian-Qian
    Chen, Hui-Sheng
    Yang, Yi
    Zhang, Meng
    Wu, Shi-Wen
    Meng, Yao
    Li, Ming-Li
    Lin, Qian-Qian
    Liebeskind, David S. S.
    Huang, Yi-Ning
    Xu, Wei-Hai
    EUROPEAN JOURNAL OF NEUROLOGY, 2023, 30 (10) : 3172 - 3181
  • [9] High-resolution magnetic resonance imaging of acute intracranial artery thrombus
    Zhang, Zongmuyu
    Si, Qianqian
    Chen, Huisheng
    Yang, Yi
    Zhang, Meng
    Wu, Shiwen
    Meng, Yao
    Li, Mingli
    Lin, Qianqian
    Liebeskind, David
    Huang, Yining
    Xu, Weihai
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2023, 455
  • [10] Accelerated parallel magnetic resonance imaging with compressed sensing using structured sparsity
    Dwork, Nicholas
    Gordon, Jeremy W.
    Englund, Erin K.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (03)