High-Resolution Magnetic Resonance Imaging Using Compressed Sensing for Intracranial and Extracranial Arteries: Comparison with Conventional Parallel Imaging

被引:29
作者
Suh, Chong Hyun [1 ,2 ]
Jung, Seung Chai [1 ,2 ]
Lee, Ho Beom [1 ,2 ]
Cho, Se Jin [1 ,2 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Asan Med Ctr, Res Inst Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
关键词
Intracranial artery disease; Image quality; Undersampling; Reconstruction method; Signal-to-noise ratio; Contrast-to-noise ratio; Compressed sensing; DIGITAL-SUBTRACTION-ANGIOGRAPHY; VESSEL WALL; BLACK; MRI; DIAGNOSIS;
D O I
10.3348/kjr.2018.0424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare conventional sensitivity encoding (SENSE) to compressed sensing plus SENSE (CS) for high-resolution magnetic resonance imaging (HR-MRI) of intracranial and extracranial arteries. Materials and Methods: HR-MRI was performed in 14 healthy volunteers. Three-dimensional T1-weighted imaging (T1WI) and proton density-weighted imaging (PD) were acquired using CS or SENSE under the same total acceleration factors (AF(t))-5.5, 6.8, and 9.7 for T1WI and 3.2, 4.0, and 5.8 for PD-to achieve reduced scanning times in comparison with the original imaging sequence (SENSE T1WI, AF(t) 3.5; SENSE PD, AF(t) 2.0) using the 3-tesla system. Two neuroradiologists measured signalto-noise ratio (SNR) and contrast-to-noise ratio (CNR), and used visual scoring systems to assess image quality. Acceptable imaging was defined as a visual score >= 2. Repeated measures analysis of variance and Cochran's Q test were performed. Results: CS yielded better image quality and vessel delineation than SENSE in T1WI with AF(t) of 5.5, 6.8, and 9.7, and in PD with AF(t) of 5.8 (p < 0.05). CS T1WI with AF(t) of 5.5 and CS PD with AF(t) of 3.2 and 4.0 did not differ significantly from original imaging (p > 0.05). SNR and CNR in CS were higher than they were in SENSE, but lower than they were in the original images (p < 0.05). CS yielded higher proportions of acceptable imaging than SENSE (CS T1WI with AF(t) of 6.8 and PD with AF(t) of 5.8; p < 0.0167). Conclusion: CS is superior to SENSE, and may be a reliable acceleration method for vessel HR-MRI using AF(t) of 5.5 for T1WI, and 3.2 and 4.0 for PD.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 19 条
  • [1] Vessel Wall Imaging of the Intracranial and Cervical Carotid Arteries
    Choi, Young Jun
    Jung, Seung Chai
    Lee, Deok Hee
    [J]. JOURNAL OF STROKE, 2015, 17 (03) : 238 - 255
  • [2] Intracranial Artery Steno-Occlusion: Diagnosis by Using Two-dimensional Spatially Selective Radiofrequency Excitation Pulse MR Imaging
    Chung, Mi Sun
    Jung, Seung Chai
    Kim, Seon-Ok
    Kim, Ho Sung
    Choi, Choong Gon
    Kim, Sang Joon
    Kwon, Sun U.
    Kang, Dong-Wha
    Kim, Jong S.
    [J]. RADIOLOGY, 2017, 284 (03) : 834 - 843
  • [3] Daniel P., 2012, Int. J. Comput. Sci. Eng.Techno., V2, P776, DOI [10.1016/J.CIRP.2014.05.011, DOI 10.1016/J.CIRP.2014.05.011]
  • [4] Whole-Brain Intracranial Vessel Wall Imaging at 3 Tesla Using Cerebrospinal Fluid-Attenuated T1-Weighted 3D Turbo Spin Echo
    Fan, Zhaoyang
    Yang, Qi
    Deng, Zixin
    Li, Yuxia
    Bi, Xiaoming
    Song, Shlee
    Li, Debiao
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1142 - 1150
  • [5] Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging
    Itskovich, VV
    Mani, V
    Mizsei, G
    Aguinaldo, JGS
    Samber, DD
    Macaluso, F
    Wisdom, P
    Fayad, ZA
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (04) : 459 - 467
  • [6] Assessment of Malignant Potential in Intraductal Papillary Mucinous Neoplasms of the Pancreas: Comparison between Multidetector CT and MR Imaging with MR Cholangiopancreatography
    Kang, Hyo-Jin
    Lee, Jeong Min
    Joo, Ijin
    Hur, Bo Yun
    Jeon, Ju Hyeon
    Jang, Jin-Young
    Lee, Kyoungbun
    Ryu, Ji Kon
    Han, Joon Koo
    Choi, Byung Ihn
    [J]. RADIOLOGY, 2016, 279 (01) : 128 - 139
  • [7] Comparison of High-Resolution MR Imaging and Digital Subtraction Angiography for the Characterization and Diagnosis of Intracranial Artery Disease
    Lee, N. J.
    Chung, M. S.
    Jung, S. C.
    Kim, H. S.
    Choi, C. -G.
    Kim, S. J.
    Lee, D. H.
    Suh, D. C.
    Kwon, S. U.
    Kang, D. -W.
    Kim, J. S.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2245 - 2250
  • [8] Compressed sensing based simultaneous black- and gray-blood carotid vessel wall MR imaging
    Li, Bo
    Li, Hao
    Kong, Hanjing
    Dong, Li
    Zhang, Jue
    Fang, Jing
    [J]. MAGNETIC RESONANCE IMAGING, 2017, 38 : 214 - 223
  • [9] An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging
    Li, Guobin
    Hennig, Juergen
    Raithel, Esther
    Buechert, Martin
    Paul, Dominik
    Korvink, Jan G.
    Zaitsev, Maxim
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (05): : 459 - 472
  • [10] Sparse MRI: The application of compressed sensing for rapid MR imaging
    Lustig, Michael
    Donoho, David
    Pauly, John M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1182 - 1195