Development of a disposable amperometric immunosensor for the detection of ecstasy and its analogues using screen-printed electrodes

被引:27
作者
Butler, D [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Sensors Dev Grp, Cork, Ireland
关键词
ecstasy; immunosensor; screen-printed electrodes; saliva; urine;
D O I
10.1016/j.aca.2005.09.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric immunosensor for the specific and simple detection of 3,4-methylenedioxyamphetamine (MDA) and its analogues, 3,4methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) in saliva and urine was developed. A direct competitive assay in which free analyte and horseradish peroxidase labelled species were simultaneously added to an immobilised polyclonal antibody was employed. Both MDA and MDMA could be labelled with the enzyme and the use of an MDMA-HRP tracer greatly enhanced the sensitivity of the assay. Amperometric detection was per-formed at +100mV versus Ag/AgCl, using tetramethylbenzidine (TMB)/H2O2 as substrate. The antibody, raised specifically against the methylenedioxy moiety of an MDA-BSA immunogen allowed highly specific detection of these analogues with negligible cross-reactivity towards any other amphetamine related compounds. Total assay time was 45 min and the standard curve using MDA could be evaluated within the range 0.61-400 ng ml(-1) with corresponding limit of detection (LOD) of 0.36 and 0.042 ng ml(-1) for saliva and urine, respectively. The cross-reactivity pattern of the analytes was determined and showed the order of sensitivity increased with increased alkyl chain length (MDA < MDMA < MDEA). The overall performance of the sensor, working range, precision and sensitivity demonstrate its usefulness for rapid and direct measurement of methylenedioxy analogues of ecstasy in saliva and urine. The sensor has better specificity than any previous method for ecstasy, with greater sensitivity than ELISA methods, is less expensive/assay with an "easier to use" format than previous methods. The detection works in saliva or urine, eliminating requirement of blood sampling, with improved precision. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
[41]   Surface modification of screen-printed electrode with PVA and its application to construct an immunosensor [J].
Pourbagher, Narges ;
Omidfar, Kobra ;
Ahmadi, Anita ;
Shirazi, Hanieh ;
Zarei, Hajar ;
Dehdast, Ahmad .
CLINICAL BIOCHEMISTRY, 2011, 44 (13) :S220-S220
[42]   Quantitative Raman spectroelectrochemistry using silver screen-printed electrodes [J].
Martin-Yerga, Daniel ;
Perez-Junquera, Alejandro ;
Begona Gonzalez-Garcia, Maria ;
Perales-Rondon, Juan V. ;
Heras, Aranzazu ;
Colina, Alvaro ;
Hernandez-Santos, David ;
Fanjul-Bolado, Pablo .
ELECTROCHIMICA ACTA, 2018, 264 :183-190
[43]   Immobilization of enzyme on screen-printed electrode by exposure to glutaraldehyde vapour for the construction of amperometric acetylcholinesterase electrodes [J].
Li, YG ;
Zhou, YX ;
Feng, JL ;
Jiang, ZH ;
Ma, LR .
ANALYTICA CHIMICA ACTA, 1999, 382 (03) :277-282
[44]   Characterisation of Prussian blue modified screen-printed electrodes for thiol detection [J].
Ricci, F ;
Arduini, F ;
Amine, A ;
Moscone, D ;
Palleschi, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 563 (02) :229-237
[45]   Screen-printed enzyme electrodes for the detection of marker analytes during winemaking [J].
Lupu, A ;
Compagnone, D ;
Palleschi, G .
ANALYTICA CHIMICA ACTA, 2004, 513 (01) :67-72
[46]   Disposable immunosensor for human cardiac troponin T based on streptavidin-microsphere modified screen-printed electrode [J].
Silva, Barbara V. M. ;
Cavalcanti, Igor T. ;
Mattos, Alessandra B. ;
Moura, Patricia ;
Sotomayor, Maria Del Pilar T. ;
Dutra, Rosa F. .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (03) :1062-1067
[47]   Chemically modified platinum screen-printed electrodes for electrochemical detection of acetylene [J].
Izumi, F. ;
de Souza, C. A. A. ;
dos Santos Filho, S. G. ;
Gongora-Rubio, M. R. .
2016 31ST SYMPOSIUM ON MICROELECTRONICS TECHNOLOGY AND DEVICES (SBMICRO), 2016,
[48]   Screen-Printed Electrodes Testing for Detection of Potential Stress Biomarkers in Sweat [J].
Maria João Nunes ;
Gabriel N. Valério ;
Alejandro Samhan-Arias ;
José J. G. Moura ;
Carlos Rouco ;
João Paulo Sousa ;
Cristina M. Cordas .
Electrocatalysis, 2022, 13 :299-305
[49]   A comparison of amperometric screen-printed, carbon electrodes and their application to the analysis of phenolic compounds present in beers [J].
Cummings, EA ;
Linquette-Mailley, S ;
Mailley, P ;
Cosnier, S ;
Eggins, BR ;
McAdams, ET .
TALANTA, 2001, 55 (05) :1015-1027
[50]   Impedimetric immunosensor for dengue diagnosis using graphite screen-printed electrodes coated with poly(4-aminophenylacetic acid) [J].
Thiago Coimbra Pimenta ;
Cátia da Cruz Santos ;
Ronaldo Luís Thomasini ;
Lucas Franco Ferreira .
Biomedical Microdevices, 2018, 20