Development of a disposable amperometric immunosensor for the detection of ecstasy and its analogues using screen-printed electrodes

被引:27
作者
Butler, D [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Sensors Dev Grp, Cork, Ireland
关键词
ecstasy; immunosensor; screen-printed electrodes; saliva; urine;
D O I
10.1016/j.aca.2005.09.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric immunosensor for the specific and simple detection of 3,4-methylenedioxyamphetamine (MDA) and its analogues, 3,4methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) in saliva and urine was developed. A direct competitive assay in which free analyte and horseradish peroxidase labelled species were simultaneously added to an immobilised polyclonal antibody was employed. Both MDA and MDMA could be labelled with the enzyme and the use of an MDMA-HRP tracer greatly enhanced the sensitivity of the assay. Amperometric detection was per-formed at +100mV versus Ag/AgCl, using tetramethylbenzidine (TMB)/H2O2 as substrate. The antibody, raised specifically against the methylenedioxy moiety of an MDA-BSA immunogen allowed highly specific detection of these analogues with negligible cross-reactivity towards any other amphetamine related compounds. Total assay time was 45 min and the standard curve using MDA could be evaluated within the range 0.61-400 ng ml(-1) with corresponding limit of detection (LOD) of 0.36 and 0.042 ng ml(-1) for saliva and urine, respectively. The cross-reactivity pattern of the analytes was determined and showed the order of sensitivity increased with increased alkyl chain length (MDA < MDMA < MDEA). The overall performance of the sensor, working range, precision and sensitivity demonstrate its usefulness for rapid and direct measurement of methylenedioxy analogues of ecstasy in saliva and urine. The sensor has better specificity than any previous method for ecstasy, with greater sensitivity than ELISA methods, is less expensive/assay with an "easier to use" format than previous methods. The detection works in saliva or urine, eliminating requirement of blood sampling, with improved precision. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
[31]   A label-free impedimetric immunosensor for zearalenone based on CS-CNT-Pd nanocomposite modified screen-printed disposable electrodes [J].
Kumar, V. Sunil ;
Kummari, Shekher ;
Catanante, Gaelle ;
Gobi, K. Vengatajalabathy ;
Marty, Jean Louis ;
Goud, K. Yugender .
SENSORS AND ACTUATORS B-CHEMICAL, 2023, 377
[32]   Amperometric immunosensor for the determination of ceruloplasmin in human serum and urine based on covalent binding to carbon nanotubes-modified screen-printed electrodes [J].
Garcinuno, B. ;
Ojeda, I. ;
Moreno-Guzman, M. ;
Gonzalez-Cortes, A. ;
Yanez-Sedeno, P. ;
Pingarron, J. M. .
TALANTA, 2014, 118 :61-67
[33]   A Broad-Range Disposable Electrochemical Biosensor Based on Screen-Printed Carbon Electrodes for Detection of Human Noroviruses [J].
Wang, Nan ;
Pan, Guiying ;
Guan, Shimin ;
Rong, Shaofeng ;
Wang, Dapeng ;
Gao, Zhiyong ;
Tian, Peng ;
Li, Qianqian .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
[34]   Amperometric detection of triclosan with screen-printed carbon nanotube electrodes modified with Guinea Grass (Panicum maximum) peroxidase [J].
Orduz, Angie E. ;
Gutierrez, Jorge A. ;
Blanco, Sergio I. ;
Castillo, John J. .
UNIVERSITAS SCIENTIARUM, 2019, 24 (02) :363-379
[35]   Use of Screen-printed Electrodes Modified by Prussian Blue and Analogues in Sensing of Cysteine [J].
Bonacin, Juliano A. ;
Dos Santos, Pamyla L. ;
Katic, Vera ;
Foster, Christopher W. ;
Banks, Craig E. .
ELECTROANALYSIS, 2018, 30 (01) :170-179
[36]   Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes [J].
Munteanu, Florentina-Daniela ;
Titoiu, Ana Maria ;
Marty, Jean-Louis ;
Vasilescu, Alina .
SENSORS, 2018, 18 (03)
[37]   Comparison of different carbon ink based screen-printed electrodes towards amperometric immunosensing [J].
V. K. Rao ;
M. K. Sharma ;
P. Pandey ;
K. Sekhar .
World Journal of Microbiology and Biotechnology, 2006, 22 :1135-1143
[38]   Comparison of different carbon ink based screen-printed electrodes towards amperometric immunosensing [J].
Rao, V. K. ;
Sharma, M. K. ;
Pandey, P. ;
Sekhar, K. .
WORLD JOURNAL OF MICROBIOLOGY & BIOTECHNOLOGY, 2006, 22 (11) :1135-1143
[39]   A disposable amperometric immunosensor for α-1-fetoprotein based on enzyme-labeled antibody/chitosan-membrane-modified screen-printed carbon electrode [J].
Yu, H ;
Yan, F ;
Dai, Z ;
Ju, HX .
ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) :98-105
[40]   Direct detection of myoglobin in whole blood using a disposable amperometric immunosensor [J].
O'Regan, TM ;
O'Riordan, LJ ;
Pravda, M ;
O'Sullivan, CK ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 2002, 460 (02) :141-150