Development of a disposable amperometric immunosensor for the detection of ecstasy and its analogues using screen-printed electrodes

被引:27
作者
Butler, D [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Sensors Dev Grp, Cork, Ireland
关键词
ecstasy; immunosensor; screen-printed electrodes; saliva; urine;
D O I
10.1016/j.aca.2005.09.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric immunosensor for the specific and simple detection of 3,4-methylenedioxyamphetamine (MDA) and its analogues, 3,4methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) in saliva and urine was developed. A direct competitive assay in which free analyte and horseradish peroxidase labelled species were simultaneously added to an immobilised polyclonal antibody was employed. Both MDA and MDMA could be labelled with the enzyme and the use of an MDMA-HRP tracer greatly enhanced the sensitivity of the assay. Amperometric detection was per-formed at +100mV versus Ag/AgCl, using tetramethylbenzidine (TMB)/H2O2 as substrate. The antibody, raised specifically against the methylenedioxy moiety of an MDA-BSA immunogen allowed highly specific detection of these analogues with negligible cross-reactivity towards any other amphetamine related compounds. Total assay time was 45 min and the standard curve using MDA could be evaluated within the range 0.61-400 ng ml(-1) with corresponding limit of detection (LOD) of 0.36 and 0.042 ng ml(-1) for saliva and urine, respectively. The cross-reactivity pattern of the analytes was determined and showed the order of sensitivity increased with increased alkyl chain length (MDA < MDMA < MDEA). The overall performance of the sensor, working range, precision and sensitivity demonstrate its usefulness for rapid and direct measurement of methylenedioxy analogues of ecstasy in saliva and urine. The sensor has better specificity than any previous method for ecstasy, with greater sensitivity than ELISA methods, is less expensive/assay with an "easier to use" format than previous methods. The detection works in saliva or urine, eliminating requirement of blood sampling, with improved precision. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
[1]   Disposable amperometric immunosensor for the detection of polycyclic aromatic hydrocarbons (PAHs) using screen-printed electrodes [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) :73-82
[2]   A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen [J].
Yan, Mei ;
Zang, Dejin ;
Ge, Shenguang ;
Ge, Lei ;
Yu, Jinghua .
BIOSENSORS & BIOELECTRONICS, 2012, 38 (01) :355-361
[3]   Impedimetric Label-Free Immunosensor on Disposable Modified Screen-Printed Electrodes for Ochratoxin A [J].
Malvano, Francesca ;
Albanese, Donatella ;
Crescitelli, Alessio ;
Pilloton, Roberto ;
Esposito, Emanuela .
BIOSENSORS-BASEL, 2016, 6 (03)
[4]   Detection of pneumolysin in human urine using an immunosensor on screen-printed carbon electrodes [J].
Díaz-González, M ;
González-García, MB ;
Costa-García, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) :1005-1011
[5]   Disposable screen-printed carbon electrodes for dual Electrochemiluminescence/Amperometric detection: Sequential injection analysis of oxalate [J].
Chin, Mei-Hsin ;
Wu, Han ;
Chen, Jyh-Cheng ;
Muthuraman, Govindan ;
Zen, Jyh-Myng .
ELECTROANALYSIS, 2007, 19 (22) :2301-2306
[6]   Indirect Amperometric Detection of Glucose in Simulated Urine Using Screen-Printed Electrodes [J].
Huseinov, Artur ;
Alvarez, Noe T. .
JOURNAL OF CHEMICAL EDUCATION, 2024, 101 (03) :1139-1145
[7]   Amperometric immunosensor for granulocyte-macrophage colony-stimulating factor using screen-printed electrodes [J].
Crowley, E ;
O'Sullivan, C ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) :171-178
[8]   Screen-Printed Electrodes for Amperometric Determination of Iodide [J].
Khodari, M. ;
Bilitewski, U. ;
Basry, A. A. H. .
ELECTROANALYSIS, 2015, 27 (02) :281-284
[9]   Development of a disposable immunosensor for the detection of human heart fatty-acid binding protein in human whole blood using screen-printed carbon electrodes [J].
O'Regan, TM ;
Pravda, M ;
O'Sullivan, CK ;
Guilbault, GG .
TALANTA, 2002, 57 (03) :501-510
[10]   Immunosensor for Mycobacterium tuberculosis on screen-printed carbon electrodes [J].
Díaz-González, M ;
González-García, MB ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2035-2043