Development of a disposable amperometric immunosensor for the detection of ecstasy and its analogues using screen-printed electrodes

被引:27
|
作者
Butler, D [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Sensors Dev Grp, Cork, Ireland
关键词
ecstasy; immunosensor; screen-printed electrodes; saliva; urine;
D O I
10.1016/j.aca.2005.09.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric immunosensor for the specific and simple detection of 3,4-methylenedioxyamphetamine (MDA) and its analogues, 3,4methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) in saliva and urine was developed. A direct competitive assay in which free analyte and horseradish peroxidase labelled species were simultaneously added to an immobilised polyclonal antibody was employed. Both MDA and MDMA could be labelled with the enzyme and the use of an MDMA-HRP tracer greatly enhanced the sensitivity of the assay. Amperometric detection was per-formed at +100mV versus Ag/AgCl, using tetramethylbenzidine (TMB)/H2O2 as substrate. The antibody, raised specifically against the methylenedioxy moiety of an MDA-BSA immunogen allowed highly specific detection of these analogues with negligible cross-reactivity towards any other amphetamine related compounds. Total assay time was 45 min and the standard curve using MDA could be evaluated within the range 0.61-400 ng ml(-1) with corresponding limit of detection (LOD) of 0.36 and 0.042 ng ml(-1) for saliva and urine, respectively. The cross-reactivity pattern of the analytes was determined and showed the order of sensitivity increased with increased alkyl chain length (MDA < MDMA < MDEA). The overall performance of the sensor, working range, precision and sensitivity demonstrate its usefulness for rapid and direct measurement of methylenedioxy analogues of ecstasy in saliva and urine. The sensor has better specificity than any previous method for ecstasy, with greater sensitivity than ELISA methods, is less expensive/assay with an "easier to use" format than previous methods. The detection works in saliva or urine, eliminating requirement of blood sampling, with improved precision. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
  • [1] Disposable amperometric immunosensor for the detection of 17-β estradiol using screen-printed electrodes
    Butler, D
    Guilbault, GG
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) : 692 - 699
  • [2] Disposable amperometric immunosensor for the detection of polycyclic aromatic hydrocarbons (PAHs) using screen-printed electrodes
    Fähnrich, KA
    Pravda, M
    Guilbault, GG
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (01): : 73 - 82
  • [3] Amperometric immunosensor for the detection of Vibrio cholerae O1 using disposable screen-printed electrodes
    Rao, Vepa K.
    Sharma, Mukesh K.
    Goel, Ajay K.
    Singh, Lokendra
    Sekhar, Krishnamurthi
    ANALYTICAL SCIENCES, 2006, 22 (09) : 1207 - 1211
  • [4] Amperometric Immunosensor for the Detection of Vibrio cholerae O1 Using Disposable Screen-printed Electrodes
    Vepa K. Rao
    Mukesh K. Sharma
    Ajay K. Goel
    Lokendra Singh
    Krishnamurthi Sekhar
    Analytical Sciences, 2006, 22 : 1207 - 1211
  • [5] Design and development of an amperometric immunosensor based on screen-printed electrodes
    Mistry, Kalyan Kumar
    Layek, Keya
    Chell, Tarak Nath
    Chaudhuri, Chirasree Roy
    Saha, Hiranmay
    ANALYTICAL METHODS, 2016, 8 (15) : 3096 - 3101
  • [6] A highly sensitive electrochemical immunosensor for zearalenone using screen-printed disposable electrodes
    Goud, K. Yugender
    Kumar, V. Sunil
    Hayat, Akhtar
    Gobi, K. Vengatajalabath
    Song, Hocheol
    Kim, Ki-Hyun
    Marty, Jean Louis
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 832 : 336 - 342
  • [7] A disposable electrochemical immunosensor based on carbon screen-printed electrodes for the detection of prostate specific antigen
    Yan, Mei
    Zang, Dejin
    Ge, Shenguang
    Ge, Lei
    Yu, Jinghua
    BIOSENSORS & BIOELECTRONICS, 2012, 38 (01): : 355 - 361
  • [8] Detection of ricin in water samples using disposable screen-printed electrodes
    Suresh, S.
    Kumar, Om
    Kolhe, Pawan
    Rao, V. Kameswara
    Sekhar, K.
    DEFENCE SCIENCE JOURNAL, 2007, 57 (06) : 839 - 844
  • [9] Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode
    Darain, F
    Park, SU
    Shim, YB
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6): : 773 - 780
  • [10] AMPEROMETRIC DETERMINATION OF COPPER USING SCREEN-PRINTED ELECTRODES
    SOMASUNDRUM, M
    BANNISTER, JV
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 15 (1-3) : 203 - 208