PROSPECTIVE EVALUATION OF VISUAL ACUITY AGREEMENT BETWEEN STANDARD EARLY TREATMENT DIABETIC RETINOPATHY STUDY CHART AND A HANDHELD EQUIVALENT IN EYES WITH RETINAL PATHOLOGY

被引:1
作者
Rahimy, Ehsan [1 ]
Reddy, Sahitya [1 ]
DeCroos, Francis Char [1 ]
Khan, M. Ali [1 ]
Boyer, David S. [2 ]
Gupta, Omesh P. [1 ]
Regillo, Carl D. [1 ]
Haller, Julia A. [1 ]
机构
[1] Thomas Jefferson Univ, Wills Eye Hosp, Retina Serv, Philadelphia, PA 19107 USA
[2] Retina Vitreous Associates Med Grp, Los Angeles, CA USA
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2015年 / 35卷 / 08期
关键词
age-related macular degeneration; diabetic macular edema; ETDRS; Snellen; retinal disease; retinal vein occlusion; vision testing; visual acuity; CLINICAL-RESEARCH; CARD ASSESSMENT; OPHTHALMOLOGY; RELIABILITY; CATARACT; PROTOCOL; TRIALS;
D O I
10.1097/IAE.0000000000000518
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart.Methods:Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions.Results:The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease.Conclusion:The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.
引用
收藏
页码:1680 / 1687
页数:8
相关论文
共 26 条
[1]  
BAILEY IL, 1976, AM J OPTOM PHYS OPT, V53, P740
[2]   A computerized method of visual acuity testing: Adaptation of the early treatment of diabetic retinopathy study testing protocol [J].
Beck, RW ;
Moke, PS ;
Turpin, AH ;
Ferris, FL ;
Sangiovanni, JP ;
Johnson, CA ;
Birch, EE ;
Chandler, DL ;
Cox, TA ;
Blair, RC ;
Kraker, RT .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (02) :194-205
[3]   Evidence-based practice in acute ophthalmology [J].
Bhatt, R. ;
Sandramouli, S. .
EYE, 2007, 21 (07) :976-983
[4]   REPRODUCIBILITY OF REFRACTION AND VISUAL-ACUITY MEASUREMENT UNDER A STANDARD PROTOCOL [J].
BLACKHURST, DW ;
MAGUIRE, MG .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1989, 9 (03) :163-169
[5]  
Camparini M, 2001, INVEST OPHTH VIS SCI, V42, P1226
[6]   Measurement and analysis of visual acuity in multicenter randomized clinical trials in the United States: Findings from a survey [J].
Dong, LM ;
Marsh, MJ ;
Hawkins, BS .
OPHTHALMIC EPIDEMIOLOGY, 2003, 10 (03) :149-165
[7]   THE USE OF ACCURATE VISUAL-ACUITY MEASUREMENTS IN CLINICAL ANTI-CATARACT FORMULATION TRIALS [J].
ELLIOTT, DB ;
SHERIDAN, M .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (04) :397-401
[8]   Comparison of visual acuity in macular degeneration patients measured with Snellen and Early Treatment Diabetic Retinopathy Study Charts [J].
Falkenstein, Iryna A. ;
Cochran, Denine E. ;
Azen, Stanley P. ;
Dustin, Laurie ;
Tammewar, Ajay M. ;
Kozak, Igor ;
Freeman, William R. .
OPHTHALMOLOGY, 2008, 115 (02) :319-323
[9]   Standardizing the measurement of visual acuity for clinical research studies - Guidelines from the eye care technology forum [J].
Ferris, FL ;
Bailey, I .
OPHTHALMOLOGY, 1996, 103 (01) :181-182
[10]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96