Low-density solvent-based dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of warfarin in human plasma

被引:51
作者
Ghambari, Hoda [1 ]
Hadjmohammadi, Mohammadreza [1 ]
机构
[1] Univ Mazandaran, Dept Chem, Babol Sar 4741695447, Iran
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2012年 / 899卷
关键词
Low-density solvent; Dispersive liquid-liquid microextraction; Warfarin; HPLC; Sample preparation; Plasma sample analysis; POLYCYCLIC AROMATIC-HYDROCARBONS; TANDEM MASS-SPECTROMETRY; PHASE MICROEXTRACTION; ORGANOCHLORINE PESTICIDES; BIOLOGICAL-FLUIDS; TRACE LEVELS; ENANTIOMERS; VALIDATION; SEPARATION; LIGHTER;
D O I
10.1016/j.jchromb.2012.04.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Extraction and determination of warfarin, a widely used anticoagulant drug, in human plasma were performed using a new generation of dispersive liquid-liquid microextraction (DLLME) and high performance liquid chromatography (HPLC). The extraction procedure is based on extraction solvents lighter than water and performing of extraction in a specially designed extraction cell. Some important parameters, including kind and volume of extraction and disperser solvents, pH of the sample solution, salt concentration in the sample solution and extraction time were investigated and optimized. Under the optimized conditions (150 mu L 1-octanol as extraction solvent, 150 mu L methanol as disperser solvent, pH(sample) = 2.3, extraction time of 2 min, without salt addition), limit of detection (LOD) of 5 ng mL(-1) and extraction recovery of 91.0% were obtained. The calibration curve was linear within the range of 15-3000 ng mL(-1) with the square of correlation coefficient (R-2) of 0.998. Repeatability and reproducibility of method based on five replicate extraction and determination were 2.8% and 6.5%, respectively. The proposed method was applied successfully for the determination of warfarin in plasma sample from a patient under treatment with this drug, and was demonstrated to be sensitive, efficient, and convenient. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 34 条
[1]   Low-density extraction solvent-based solvent terminated dispersive liquid-liquid microextraction combined with gas chromatography-tandem mass spectrometry for the determination of carbamate pesticides in water samples [J].
Chen, Hao ;
Chen, Ruiwen ;
Li, Shengqing .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) :1244-1248
[2]   Determination of organochlorine pesticides in water samples by dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Pastor, Raul ;
Santiago, Noemi ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2009, 649 (02) :218-221
[3]   Multisyringe flow injection spectrofluorimetric determination of warfarin at trace levels with on-line solid-phase preconcentration [J].
de Armas, G ;
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) :13-23
[4]   HPLC determination of warfarin and acenocoumarol in raw materials and pharmaceuticals [J].
De Orsi, D ;
Gagliardi, L ;
Turchetto, L ;
Tonelli, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) :891-895
[5]   Fatal intoxications by acenocoumarol, phenprocoumon and warfarin: Method validation in blood using the total error approach [J].
Denooz, Raphael ;
Douamba, Zoenabo ;
Charlier, Corinne .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23) :2344-2348
[6]   Use of a capillary tube for collecting an extraction solvent lighter than water after dispersive liquid-liquid microextraction and its application in the determination of parabens in different samples by gas chromatography-Flame ionization detection [J].
Farajzadeh, M. A. ;
Djozan, Dj. ;
Bakhtiyari, R. Fazeli .
TALANTA, 2010, 81 (4-5) :1360-1367
[7]   Dispersive liquid-liquid microextraction using extraction solvent lighter than water [J].
Farajzadeh, Mir Ali ;
Seyedi, Seyed Esmaeil ;
Shalamzari, Mohammad Safi ;
Bamorowat, Mehdi .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) :3191-3200
[8]   Assay of anti-coagulant drug warfarin sodium in pharmaceutical formulation and human biological fluids by square-wave adsorptive cathodic stripping voltammetry [J].
Ghoneim, MM ;
Tawfik, A .
ANALYTICA CHIMICA ACTA, 2004, 511 (01) :63-69
[9]   Low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction for the fast determination of trace levels of sixteen priority polycyclic aromatic hydrocarbons in environmental water samples [J].
Guo, Liang ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) :5040-5046
[10]   Three-phase hollow fiber liquid phase microextraction of warfarin from human plasma and its determination by high-performance liquid chromatography [J].
Hadjmohammadi, Mohammadreza ;
Ghambari, Hoda .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 :44-49