Influence of Multiple Peak Light-emitting-diode Curing Unit Beam Homogenization Tips on Microhardness of Resin Composites

被引:24
作者
Soto-Montero, J. [1 ,2 ]
Nima, G. [3 ]
Rueggeberg, F. A. [4 ]
Dias, C. T. S. [5 ]
Giannini, M. [6 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Operat Dent, Piracicaba, Brazil
[2] Univ Costa Rica, Sch Dent, Dept Restorat Dent, San Jose, Costa Rica
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dent Mat, Piracicaba, Brazil
[4] Augusta Univ, Dent Coll Georgia, Dent Mat, Augusta, GA USA
[5] Univ Sao Paulo, Luiz de Queiroz Higher Sch Agr, Dept Stat Math, Piracicaba, Brazil
[6] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, Brazil
关键词
IRRADIANCE DISTRIBUTION; MONOMER CONVERSION; EMISSION-SPECTRUM; PROFILE; VIOLET; BLUE; POLYMERIZATION; DENTISTRY; GUIDANCE; ACADEMY;
D O I
10.2341/19-027-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the effect of light curing unit (LCU) guide type (regular or homogenizing) on top and bottom microhardness of conventional and bulk-fill resin-based composites (RBCs). A polywave light-emitting-diode (LED) LCU (Bluephase Style, Ivoclar Vivadent AG) was used with two different light guides: a regular tip (RT, 935 mW/cm(2) emittance) and a homogenizer tip (HT, 851 mW/cm(2) emittance). Two conventional RBCs (Herculite Ultra [HER], Kerr Corp; Tetric EvoCeram [TEC], Ivoclar Vivadent AG) and two bulk-fill RBCs (SonicFill [SOF], Kerr Corp; Tetric EvoCeram Bulk Fill [TBF], Ivoclar Vivadent AG) were tested. Disc-shaped samples (10 mm empty set), 2-mm thick for conventional composites and 4-mm thick for bulk-fill composites were prepared. Samples were light cured according to manufacturer-recommended times. Knoop microhardness values (KHN) were obtained on the top and bottom surfaces of each specimen at locations correlated with the output of the three LED chips emitting blue (456 nm) or violet light (409 nm). Beam profile analysis using both light guides was also performed. Microhardness of each composite was analyzed using three-way analysis of variance and Tukey honestly significant difference post hoc test (alpha=0.05). Beam profile images showed better light distribution across the surface of the HT light guide. Use of the HT decreased KHN of HER at the locations of the blue LED chips at bottom of the sample but had no effect on the top surface. For TEC, use of HT increased KHN of all three LED locations at the top surface. Use of the HT increased KHN of SOF at locations corresponding to one of the blue and the violet LED chips at the bottom surface. For TBF, HT increased KHN at all top surface locations. All RBCs showed higher mean KHN at the top compared with the bottom surfaces. In general, all composites presented a higher KHN at the blue LED areas regardless of the surface or the tip used. Results suggest that the homogenizer light guide resulted in significantly increased microhardness at the top, in composite resins containing alternative photoinitiators; however, that effect was not observed at the bottom surfaces.
引用
收藏
页码:327 / 338
页数:12
相关论文
共 38 条
[1]   Post-cure depth of cure of bulk fill dental resin-composites [J].
Alrahlah, A. ;
Silikas, N. ;
Watts, D. C. .
DENTAL MATERIALS, 2014, 30 (02) :149-154
[2]   Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths [J].
ALShaafi, Maan M. ;
Haenel, Thomas ;
Sullivan, Braden ;
Labrie, Daniel ;
Alqahtani, Mohammed Q. ;
Price, Richard B. .
JOURNAL OF DENTISTRY, 2016, 45 :14-18
[3]   Stability of the Light Output, Oral Cavity Tip Accessibility in Posterior Region and Emission Spectrum of Light-Curing Units [J].
Andre, C. B. ;
Nima, G. ;
Sebold, M. ;
Giannini, M. ;
Price, R. B. .
OPERATIVE DENTISTRY, 2018, 43 (04) :398-407
[4]  
Bouschlicher MR, 2004, OPER DENT, V29, P698
[5]   Academy of Dental Materials guidance-Resin composites: Part II-Technique sensitivity (handling, polymerization, dimensional changes) [J].
Ferracane, J. L. ;
Hilton, T. J. ;
Stansbury, J. W. ;
Watts, D. C. ;
Silikas, N. ;
Ilie, N. ;
Heintze, S. ;
Cadenaro, M. ;
Hickel, R. .
DENTAL MATERIALS, 2017, 33 (11) :1171-1191
[6]   Wear and marginal breakdown of composites with various degrees of cure [J].
Ferracane, JL ;
Mitchem, JC ;
Condon, JR ;
Todd, R .
JOURNAL OF DENTAL RESEARCH, 1997, 76 (08) :1508-1516
[7]   Mechanisms of degradation of the hybrid layer in adhesive dentistry and therapeutic agents to improve bond durability-A literature review [J].
Frassetto, Andrea ;
Breschi, Lorenzo ;
Turco, Gianluca ;
Marchesi, Giulio ;
Di Lenarda, Roberto ;
Tay, Franklin R. ;
Pashley, David H. ;
Cadenaro, Milena .
DENTAL MATERIALS, 2016, 32 (02) :E41-E53
[8]  
Friedman J, 1990, United States Patent, Patent No. [4,948,215, 4948215]
[9]   Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites [J].
Fronza, Bruna Marin ;
Rueggeberg, Frederick Allen ;
Braga, Roberto Ruggiero ;
Mogilevych, Borys ;
Silva Soares, Luis Eduardo ;
Martin, Airton Abrahao ;
Ambrosano, Glaucia ;
Giannini, Marcelo .
DENTAL MATERIALS, 2015, 31 (12) :1542-1551
[10]   Bulk-Fill Composites: Effectiveness of Cure With Poly- and Monowave Curing Lights and Modes [J].
Gan, J. K. ;
Yap, A. U. ;
Cheong, J. W. ;
Arista, N. ;
Tan, C. B. K. .
OPERATIVE DENTISTRY, 2018, 43 (02) :136-143