A new method for the simultaneous determination of Fe(III), Cu(II), Pb(II), Zn(II), Cd(II), and Ni(II) in wine using differential pulse polarography

被引:10
作者
Somer, Gueler [1 ]
Caliskan, Ali Cengiz [1 ]
机构
[1] Gazi Univ, Dept Chem, TR-06500 Ankara, Turkey
关键词
Wine; Analysis; Determination; Trace elements; Polarography; PLASMA-MASS-SPECTROMETRY; TRACE-ELEMENTS; STRIPPING VOLTAMMETRY; ICP-MS; LEAD; SAMPLES; COPPER; SYSTEM;
D O I
10.1007/s10800-009-9915-1
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A new and simple differential pulse polarographic method for the analysis of wine has been established. With this method, it was possible to determine simultaneously six trace elements in wine. There was no need for time consuming extraction and separation procedures with danger of contamination. The polarogram of wet digested wine was taken initially in pH 2 acetate buffer and Pb, Cd, and Zn were determined by standard additions. Ethylene diamine tetraacetic acid (EDTA) was added and pH was increased to six by addition of NaOH. Fe and Cu were determined subsequently. The ammonia buffer, pH 9.5, was identified as the best medium for separation and determination of Ni and Zn. The quantities of trace elements were found as Cu 290 +/- A 20 mu g L(-1), Fe 8960 +/- A 50 mu g L(-1), Pb 148 +/- A 17 mu g L(-1), Cd 16 +/- A 8 mu g L(-1), Zn 460 +/- A 25 mu g L(-1), and Ni 78 +/- A 17 mu g L(-1).
引用
收藏
页码:2027 / 2033
页数:7
相关论文
共 23 条
[1]   Determination of metals in wine with atomic spectroscopy (flame-AAS, GF-AAS and ICP-AES); a review [J].
Aceto, M ;
Abollino, O ;
Bruzzoniti, MC ;
Mentasti, E ;
Sarzanin, C ;
Malandrino, M .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (02) :126-133
[2]   Trace elements determination in red and white wines using total-reflection X-ray fluorescence [J].
Anjos, MJ ;
Lopes, RT ;
de Jesus, EFO ;
Moreira, S ;
Barroso, RC ;
Castro, CRF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (12) :2227-2232
[3]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[4]  
Baldo MA, 1997, ANALYST, V122, P1, DOI 10.1039/a605370j
[5]  
Baxter MJ, 1997, FOOD CHEM, V60, P443, DOI 10.1016/S0308-8146(96)00365-2
[6]  
BRUNO P, 1978, ANALYST, V103, P868, DOI 10.1039/an9780300868
[7]   Development of a procedure for the multi-element determination of trace elements in wine by ICP-MS [J].
Castiñeira, MM ;
Brandt, R ;
von Bohlen, A ;
Jakubowski, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :553-558
[8]   ISOTOPE RATIO AND ISOTOPE-DILUTION ANALYSIS OF LEAD IN WINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DEAN, JR ;
EBDON, L ;
MASSEY, RC .
FOOD ADDITIVES AND CONTAMINANTS, 1990, 7 (01) :109-116
[9]   Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry [J].
Freschi, GPG ;
Dakuzaku, CS ;
de Moraes, M ;
Nóbrega, JA ;
Neto, JAG .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) :1987-1993
[10]   An unusual polarographic behavior of selenite in the presence of some cations [J].
Inam, R ;
Somer, G .
ANALYTICAL SCIENCES, 1998, 14 (02) :399-403