Estimating Lower Limb Kinematics Using a Reduced Wearable Sensor Count

被引:37
|
作者
Sy, Luke [1 ]
Raitor, Michael [2 ]
Del Rosario, Michael [3 ]
Khamis, Heba [4 ]
Kark, Lauren [5 ]
Lovell, Nigel H. [5 ]
Redmond, Stephen J. [5 ]
机构
[1] Univ New South Wales, Grad Sch Biomed Engn, Kensington Campus, Sydney, NSW 2052, Australia
[2] Stanford Univ, Stanford, CA 94305 USA
[3] Univ New South Wales, Grad Sch Biomed Engn, Randwick Campus, Randwick, NSW, Australia
[4] Univ Sydney, Sch EIE, Sydney, NSW, Australia
[5] Grad Sch Biomed Engn, Sydney, NSW, Australia
关键词
Pelvis; Kinematics; Biomedical monitoring; Sensors; Three-dimensional displays; Acceleration; Thigh; Constrained kalman filter; gait analysis; imu; motion capture; pose estimation; wearable devices; GAIT ANALYSIS; MOTION; VARIABILITY; MOVEMENT; ADULTS;
D O I
10.1109/TBME.2020.3026464
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Goal: This paper presents an algorithm for accurately estimating pelvis, thigh, and shank kinematics during walking using only three wearable inertial sensors. Methods: The algorithm makes novel use of a constrained Kalman filter (CKF). The algorithm iterates through the prediction (kinematic equation), measurement (pelvis position pseudo-measurements, zero velocity update, flat-floor assumption, and covariance limiter), and constraint update (formulation of hinged knee joints and ball-and-socket hip joints). Results: Evaluation of the algorithm using an optical motion capture-based sensor-to-segment calibration on nine participants (7 men and 2 women, weight 63.0 +/- 6.8 kg, height 1.70 +/- 0.06 m, age 24.6 +/- 3.9 years old), with no known gait or lower body biomechanical abnormalities, who walked within a 4 x 4 m(2) capture area shows that it can track motion relative to the mid-pelvis origin with mean position and orientation (no bias) root-mean-square error (RMSE) of 5.21 +/- 1.3 cm and 16.1 +/- 3.2 degrees, respectively. The sagittal knee and hip joint angle RMSEs (no bias) were 10.0 +/- 2.9 degrees and 9.9 +/- 3.2 degrees, respectively, while the corresponding correlation coefficient (CC) values were 0.87 +/- 0.08 and 0.74 +/- 0.12. Conclusion: The CKF-based algorithm was able to track the 3D pose of the pelvis, thigh, and shanks using only three inertial sensors worn on the pelvis and shanks. Significance: Due to the Kalman-filter-based algorithm's low computation cost and the relative convenience of using only three wearable sensors, gait parameters can be computed in real-time and remotely for long-term gait monitoring. Furthermore, the system can be used to inform real-time gait assistive devices.
引用
收藏
页码:1293 / 1304
页数:12
相关论文
共 50 条
  • [1] Estimating Lower Limb Kinematics Using a Lie Group Constrained Extended Kalman Filter with a Reduced Wearable IMU Count and Distance Measurements
    Sy, Luke Wicent F.
    Lovell, Nigel H.
    Redmond, Stephen J.
    SENSORS, 2020, 20 (23) : 1 - 28
  • [2] Estimating Lower Limb Kinematics using Distance Measurements with a Reduced Wearable Inertial Sensor Count
    Sy, Luke
    Lovell, Nigel H.
    Redmond, Stephen J.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4858 - 4862
  • [3] Estimating Lower Body Kinematics Using a Lie Group Constrained Extended Kalman Filter and Reduced IMU Count
    Sy, Luke Wicent
    Lovell, Nigel H.
    Redmond, Stephen J.
    IEEE SENSORS JOURNAL, 2021, 21 (18) : 20969 - 20979
  • [4] Predicting lower limb joint kinematics using wearable motion sensors
    Findlow, A.
    Goulermas, J. Y.
    Nester, C.
    Howard, D.
    Kenney, L. P. J.
    GAIT & POSTURE, 2008, 28 (01) : 120 - 126
  • [5] Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics
    Niswander, Wesley
    Wang, Wei
    Kontson, Kimberly
    SENSORS, 2020, 20 (21) : 1 - 16
  • [6] Lower limb kinematics during the swing phase in patients with knee osteoarthritis measured using an inertial sensor
    Tanimoto, Kenji
    Takahashi, Makoto
    Tokuda, Kazuki
    Sawada, Tomonori
    Anan, Masaya
    Shinkoda, Koichi
    GAIT & POSTURE, 2017, 57 : 236 - 240
  • [7] The Lower Limbs Kinematics Analysis by Wearable Sensor Shoes
    Li, Guangyi
    Liu, Tao
    Yi, Jingang
    Wang, Hesheng
    Li, Juan
    Inoue, Yoshio
    IEEE SENSORS JOURNAL, 2016, 16 (08) : 2627 - 2638
  • [8] Estimating vertical ground reaction forces during gait from lower limb kinematics and vertical acceleration using wearable inertial sensors
    Martinez-Pascual, David
    Catalan, Jose M.
    Blanco-Ivorra, Andrea
    Sanchis, Monica
    Aran-Ais, Francisca
    Garcia-Aracil, Nicolas
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [9] Lower Limb Sensor-to-Segment Calibration for Joint Kinematics Analysis With Inertial Measurement Units: Is There an Ideal Method?
    Pacher, Leonie
    Chatellier, Christian
    Laguillaumie, Pierre
    Vauzelle, Rodolphe
    Fradet, Laetitia
    IEEE SENSORS JOURNAL, 2022, 22 (22) : 22148 - 22160
  • [10] Inertial Sensor-Based Lower Limb Joint Kinematics: A Methodological Systematic Review
    Weygers, Ive
    Kok, Manon
    Konings, Marco
    Hallez, Hans
    De Vroey, Henri
    Claeys, Kurt
    SENSORS, 2020, 20 (03)