Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes

被引:294
作者
Rodbard, David [1 ]
机构
[1] Biomed Informat Consultants LLC, 10113 Bentcross Dr, Potomac, MD 20854 USA
关键词
Continuous glucose monitoring (CGM); Flash glucose monitoring; Multiple daily injections (MDI); Continuous subcutaneous insulin infusion (CSII); Sensor-augmented pump (SAP); Automated insulin delivery (AID); Closed-loop control (CLC); Hypoglycemia; Hyperglycemia; Time in range (TIR); Ambulatory glucose profile (AGP); Glycemic variability (GV); Artificial pancreas (AP); Type 1 diabetes (T1DM); Type 2 diabetes (T2DM); LOOP INSULIN DELIVERY; NOCTURNAL HYPOGLYCEMIC EVENTS; DEXCOM G4 PLATINUM; ARTIFICIAL PANCREAS; BLOOD-GLUCOSE; EMERGENCY-DEPARTMENT; DIABETES MANAGEMENT; SENSING TECHNOLOGY; ECONOMIC BURDEN; PREGNANT-WOMEN;
D O I
10.1089/dia.2017.0035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous Glucose Monitoring (CGM) has been demonstrated to be clinically valuable, reducing risks of hypoglycemia and hyperglycemia, glycemic variability (GV), and improving patient quality of life for a wide range of patient populations and clinical indications. Use of CGM can help reduce HbA1c and mean glucose. One CGM device, with accuracy (% MARD) of approximately 10%, has recently been approved for selfadjustment of insulin dosages (nonadjuvant use) and approved for reimbursement for therapeutic use in the United States. CGM had previously been used off-label for that purpose. CGM has been demonstrated to be clinically useful in both type 1 and type 2 diabetes for patients receiving a wide variety of treatment regimens. CGM is beneficial for people using either multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII). CGM is used both in retrospective (professional, masked) and real-time (personal, unmasked) modes: both approaches can be beneficial. When CGM is used to suspend insulin infusion when hypoglycemia is detected until glucose returns to a safe level (low-glucose suspend), there are benefits beyond sensor-augmented pump (SAP), with greater reduction in the risk of hypoglycemia. Predictive low-glucose suspend provides greater benefits in this regard. Closed-loop control with insulin provides further improvement in quality of glycemic control. A hybrid closed-loop system has recently been approved by the U.S. FDA. Closed-loop control using both insulin and glucagon can reduce risk of hypoglycemia even more. CGM facilitates rigorous evaluation of new forms of therapy, characterizing pharmacodynamics, assessing frequency and severity of hypo- and hyperglycemia, and characterizing several aspects of GV.
引用
收藏
页码:S25 / S37
页数:13
相关论文
共 137 条
[1]   From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior [J].
Acciaroli, Giada ;
Vettoretti, Martina ;
Facchinetti, Andrea ;
Sparacino, Giovanni ;
Cobelli, Claudio .
DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (08) :472-479
[2]   Retrospective Analysis of the Real-World Use of the Threshold Suspend Feature of Sensor-Augmented Insulin Pumps [J].
Agrawal, Pratik ;
Zhong, Alex ;
Welsh, John B. ;
Shah, Rajiv ;
Kaufman, Francine R. .
Diabetes Technology & Therapeutics, 2015, 17 (05) :316-319
[3]  
Agrawal Pratik, 2011, J Diabetes Sci Technol, V5, P1137
[4]   ARTIFICIAL ENDOCRINE PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W .
DIABETES, 1974, 23 (05) :389-396
[5]   CLINICAL CONTROL OF DIABETES BY ARTIFICIAL PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W ;
SCHIPPER, H ;
GANDER, R .
DIABETES, 1974, 23 (05) :397-404
[6]   Introduction [J].
不详 .
DIABETES CARE, 2017, 40 :S1-S130
[7]  
[Anonymous], 2014, J DIABETES SCI TECHN
[8]   Q-Score: development of a new metric for continuous glucose monitoring that enables stratification of antihyperglycaemic therapies [J].
Augstein, Petra ;
Heinke, Peter ;
Vogt, Lutz ;
Vogt, Roberto ;
Rackow, Christine ;
Kohnert, Klaus-Dieter ;
Salzsieder, Eckhard .
BMC ENDOCRINE DISORDERS, 2015, 15
[9]   The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System [J].
Bailey, Timothy ;
Bode, Bruce W. ;
Christiansen, Mark P. ;
Klaff, Leslie J. ;
Alva, Shridhara .
DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) :787-794
[10]   Accuracy and Acceptability of the 6-Day Enlite Continuous Subcutaneous Glucose Sensor [J].
Bailey, Timothy S. ;
Ahmann, Andrew ;
Brazg, Ronald ;
Christiansen, Mark ;
Garg, Satish ;
Watkins, Elaine ;
Welsh, John B. ;
Lee, Scott W. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 (05) :277-283