Elimination of false-positive Histoplasma antigenemia caused by human anti-rabbit antibodies in the second-generation Histoplasma antigen assay

被引:27
作者
Wheat, L. J.
Connolly, P.
Durkin, M.
Book, B. K.
Pescovitz, M. D.
机构
[1] MiraVista Diagnost, Indianapolis, IN 46241 USA
[2] Indiana Univ, Sch Med, Dept Surg, Indianapolis, IN 46202 USA
[3] Indiana Univ, Sch Med, Dept Immunol Microbiol, Indianapolis, IN USA
关键词
Histoplasma; thymoglobulin; antigen; false-positive; assay;
D O I
10.1111/j.1399-3062.2006.00151.x
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
False-positive Histoplasma antigenemia was reported in solid organ allograft recipients who had received rabbit anti-thymocyte globulin (RATG, RATG(R)) caused by human anti-rabbit antibodies (HARA). A second-generation Histoplasma antigen detection assay was developed to overcome false positivity caused by HARA. With the second-generation assay, false-positive results were eliminated in 18 of 19 cases without reduction in the sensitivity in patients with histoplasmosis. In fact, sensitivity for detection of antigenuria in patients with acquired immunodeficiency syndrome and disseminated histoplasmosis was higher in the second-generation assay Physicians should be aware of the potential for false-positive results in sandwich immunoassays in specimens from patients who have received RATG.
引用
收藏
页码:219 / 221
页数:3
相关论文
共 1 条
  • [1] Reduction in false antigenemia in the second generation Histoplasma antigen assay
    Wheat, L. Joseph
    Witt, John, III
    Durkin, Michelle
    Connolly, Patricia
    MEDICAL MYCOLOGY, 2007, 45 (02) : 169 - 171