Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images

被引:5
作者
Mauad, Leticia Queiroz [1 ]
Teixeira Doriguetto, Paulo Victor [1 ]
de Almeida, Daniela [1 ]
Castilho Fardim, Karolina Aparecida [2 ]
Machado, Alessiana Helena [3 ]
Devito, Karina Lopes [4 ]
机构
[1] Univ Fed Juiz de Fora, Sch Dent, Grad Program Dent, Juiz De Fora, MG, Brazil
[2] Sao Paulo State Univ, Sch Dent, Inst Sci & Technol, Dept Oral Diag & Surg, Sao Jose Dos Campos, SP, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, SP, Brazil
[4] Univ Fed Juiz de Fora, Sch Dent, Dept Dent Clin, Juiz De Fora, MG, Brazil
关键词
cone beam computed tomography; artefacts; ceramics; metal ceramic alloys; dental marginal adaptation; BEAM COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; CARIES; ADAPTATION; MODALITIES;
D O I
10.1259/dmfr.20200134
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate, in an in vitro study, the quantity of artefacts generated by two different restorative materials, and to determine the diagnostic accuracy of cone beam CT (CBCT) scans and periapical radiographs in identifying gaps in prosthetic crowns. Methods: A total of 30 teeth restored with metal-ceramic (n = 15) and all-ceramic (n = 15) crowns, properly adapted and with 0.30- and 0.50 mm gaps, underwent CBCT exams (with voxel sizes of 0.25 and 0.30 mm) and periapical radiographs. The artefacts generated by two different crowns were quantified and compared by the Mann-Whitney test. In addition, five examiners evaluated the presence or absence of gaps in periapical radiographs and CBCT images. The accuracy of tests was determined by the area under the receiver operatring characteristic curve and these values were compared by using the Kruskal-Wallis test. Results: There was no significant difference in artefact values between the different restorative materials and the different resolutions of CBCT images. Regarding the accuracy of the tests evaluated, periapical radiography and CBCT with voxel size 0.25 mm showed the best performance for smaller gaps (0.30 mm). For larger gaps (0.50 mm), all exams tested showed the same performance. Conclusions: Periapical radiography was still the most cost-beneficial method for the diagnosis of maladaptation in dental restorations. CBCT exams did not improve accuracy in detecting gaps in prosthetic crowns.
引用
收藏
页数:7
相关论文
共 25 条
[11]  
Konermann AC, 2010, QUINTESSENCE INT, V41, P681
[12]   Evaluation of intensity of artefacts in CBCT by radio-opacity of composite simulation models of implants in vitro [J].
Kuusisto, N. ;
Vallittu, P. K. ;
Lassila, L. V. J. ;
Huumonen, S. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (02)
[13]   Intensity of artefacts in cone beam CT examinations caused by titanium and glass fibre-reinforced composite implants [J].
Kuusisto, Niina ;
Huumonen, Sisko ;
Kotiaho, Antti ;
Haapea, Marianne ;
Rekola, Jami ;
Vallittu, Pekka .
DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (02)
[14]   Diagnostic accuracy of cone beam computed tomography sections with various thicknesses for detecting misfit between the tooth and restoration in metal-restored teeth [J].
Liedke, Gabriela Salatino ;
Spin-Neto, Rubens ;
Vizzotto, Mariana Boessio ;
da Silveira, Priscila Fernanda ;
Wenzel, Ann ;
Dias da Silveira, Heloisa Emilia .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (02) :E131-E137
[15]   Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images [J].
Machado, Alessiana Helena ;
Castilho Fardim, Karolina Aparecida ;
de Souza, Camila Furtado ;
Sotto-Maior, Bruno Salles ;
Souza Picorelli Assis, Neuza Maria ;
Devito, Karina Lopes .
DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (03)
[16]  
McGuigan Margarete B, 2018, Swiss Dent J, V128, P297
[17]   Visibility of Artificial Buccal Recurrent Caries Under Restorations Using Different Radiographic Techniques [J].
Murat, S. ;
Kamburoglu, K. ;
Isayev, A. ;
Kursun, S. ;
Yuksel, S. .
OPERATIVE DENTISTRY, 2013, 38 (02) :197-207
[18]   Evaluation of Cone-beam Computed Tomography in the Diagnosis of Vertical Root Fractures: The Influence of Imaging Modes and Root Canal Materials [J].
Neves, Frederico Sampaio ;
Freitas, Deborah Queiroz ;
Flores Campos, Paulo Sergio ;
Ekestubbe, Annika ;
Lofthag-Hansen, Sara .
JOURNAL OF ENDODONTICS, 2014, 40 (10) :1530-1536
[19]   Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography [J].
Park, Ha-Na ;
Min, Chang-Ki ;
Kim, Kyoung-A ;
Koh, Kwang-Joon .
IMAGING SCIENCE IN DENTISTRY, 2019, 49 (02) :139-151
[20]   Quantification of metal artifacts on cone beam computed tomography images [J].
Pauwels, Ruben ;
Stamatakis, Harry ;
Bosmans, Hilde ;
Bogaerts, Ria ;
Jacobs, Reinhilde ;
Horner, Keith ;
Tsiklakis, Kostas .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 :94-99