Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images

被引:5
作者
Mauad, Leticia Queiroz [1 ]
Teixeira Doriguetto, Paulo Victor [1 ]
de Almeida, Daniela [1 ]
Castilho Fardim, Karolina Aparecida [2 ]
Machado, Alessiana Helena [3 ]
Devito, Karina Lopes [4 ]
机构
[1] Univ Fed Juiz de Fora, Sch Dent, Grad Program Dent, Juiz De Fora, MG, Brazil
[2] Sao Paulo State Univ, Sch Dent, Inst Sci & Technol, Dept Oral Diag & Surg, Sao Jose Dos Campos, SP, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, SP, Brazil
[4] Univ Fed Juiz de Fora, Sch Dent, Dept Dent Clin, Juiz De Fora, MG, Brazil
关键词
cone beam computed tomography; artefacts; ceramics; metal ceramic alloys; dental marginal adaptation; BEAM COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; CARIES; ADAPTATION; MODALITIES;
D O I
10.1259/dmfr.20200134
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate, in an in vitro study, the quantity of artefacts generated by two different restorative materials, and to determine the diagnostic accuracy of cone beam CT (CBCT) scans and periapical radiographs in identifying gaps in prosthetic crowns. Methods: A total of 30 teeth restored with metal-ceramic (n = 15) and all-ceramic (n = 15) crowns, properly adapted and with 0.30- and 0.50 mm gaps, underwent CBCT exams (with voxel sizes of 0.25 and 0.30 mm) and periapical radiographs. The artefacts generated by two different crowns were quantified and compared by the Mann-Whitney test. In addition, five examiners evaluated the presence or absence of gaps in periapical radiographs and CBCT images. The accuracy of tests was determined by the area under the receiver operatring characteristic curve and these values were compared by using the Kruskal-Wallis test. Results: There was no significant difference in artefact values between the different restorative materials and the different resolutions of CBCT images. Regarding the accuracy of the tests evaluated, periapical radiography and CBCT with voxel size 0.25 mm showed the best performance for smaller gaps (0.30 mm). For larger gaps (0.50 mm), all exams tested showed the same performance. Conclusions: Periapical radiography was still the most cost-beneficial method for the diagnosis of maladaptation in dental restorations. CBCT exams did not improve accuracy in detecting gaps in prosthetic crowns.
引用
收藏
页数:7
相关论文
共 25 条
[1]   Fit of zirconia fixed partial denture: a systematic review [J].
Abduo, J. ;
Lyons, K. ;
Swain, M. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (11) :866-876
[2]   Accuracy of proximal caries depth measurements:: Comparison between limited cone beam computed tomography, storage phosphor and film radiography [J].
Akdeniz, B. Guniz ;
Grondahl, Hans-Goran ;
Magnusson, Bengt .
CARIES RESEARCH, 2006, 40 (03) :202-207
[3]   Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology [J].
Borba, Marcia ;
Miranda, Walter Gomes, Jr. ;
Cesar, Paulo Francisco ;
Griggs, Jason Allan ;
Della Bona, Alvaro .
BRAZILIAN ORAL RESEARCH, 2013, 27 (05) :396-402
[4]   Adaptation of all-ceramic fixed partial dentures [J].
Borba, Marcia ;
Cesar, Paulo F. ;
Griggs, Jason A. ;
Della Bona, Alvaro .
DENTAL MATERIALS, 2011, 27 (11) :1119-1126
[5]   Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries [J].
Charuakkra, Arnon ;
Prapayasatok, Sangsom ;
Janhom, Apirum ;
Pongsiriwet, Surawut ;
Verochana, Karune ;
Mahasantipiya, Phattaranant .
IMAGING SCIENCE IN DENTISTRY, 2011, 41 (04) :143-150
[6]   Quantitative evaluation of metal artifacts using different CBCT devices, high-density materials and field of views [J].
Codari, Marina ;
Vasconcelos, Karla de Faria ;
Pinheiro Nicolielo, Laura Ferreira ;
Neto, Francisco Haiter ;
Jacobs, Reinhilde .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (12) :1509-1514
[7]   Diagnosis of vertical root fracture in teeth close and distant to implant: an in vitro study to assess the influence of artifacts produced in cone beam computed tomography [J].
Freitas, Deborah Queiroz ;
Vasconcelos, Taruska Ventorini ;
Noujeim, Marcel .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (03) :1263-1270
[8]   Ex vivo evaluation of new 2D and 3D dental radiographic technology for detecting caries [J].
Gaalaas, Laurence ;
Tyndall, Donald ;
Mol, Andre ;
Everett, Eric T. ;
Bangdiwala, Ananta .
DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (03)
[9]   Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT [J].
Gong, X-Y ;
Meyer, E. ;
Yu, X-J ;
Sun, J-H ;
Sheng, L-P ;
Huang, K-H ;
Wu, R-Z .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (04)
[10]   Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions [J].
Haiter-Neto, F. ;
Wenzel, A. ;
Gotfredsen, E. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) :18-22