The use of rectal balloon during the delivery of intensity modulated radiotherapy (IMRT) for prostate cancer: More than just a prostate gland immobilization device?

被引:63
作者
Teh, BS [1 ]
McGary, JE [1 ]
Dong, L [1 ]
Mai, WY [1 ]
Carpenter, LS [1 ]
Lu, HH [1 ]
Chiu, JK [1 ]
Woo, SY [1 ]
Grant, WH [1 ]
Butler, EB [1 ]
机构
[1] Baylor Coll Med, Methodist Hosp, Dept Radiol, Sect Radiat Oncol, Houston, TX 77030 USA
关键词
rectal balloon; prostate cancer; radiotherapy; intensity-modulated radiotherapy (IMRT); immobilization; rectal dose sparing; dosimetric effects; reduced rectal toxicity; dose escalation;
D O I
10.1097/00130404-200211000-00012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE The purpose of this study was to investigate the role of a rectal balloon for prostate immobilization and rectal toxicity reduction in patients receiving dose-escalated intensity-modulated radiotherapy for prostate cancer. PATIENTS AND METHODS Patients with localized prostate cancer who were undergoing intensity-modulated radiotherapy were treated in a prone position, immobilized with a customized Vac-Lok bag (MED-TEC, Orange City, IA). A rectal balloon with 100 cc of air was used to immobilize the prostate. The prostate displacements were measured using computed tomography (CT)-CT fusion on 10 patients who received radioactive seed implant before intensity-modulated radiotherapy. They were scanned twice weekly during 5 weeks of intensity-modulated radiotherapy, and breathing studies were also performed. Rectal toxicity was evaluated by use of Radiation Therapy Oncology Group scoring in 100 patients. They were treated to a mean dose of 76 Gy over 35 fractions (2.17-Gy fraction size). Dose-volume histogram of the rectum was assessed. A film phantom was constructed to simulate the 4-cm diameter air cavity that was created by the rectal balloon. Kodak XV2 films (Rochester NY) were used to measure and compare dose distribution with and without the air cavity. A fraction of 1.25 Gy was delivered to the phantom at isocenter with 15-MV photons by use of the NOMOS Peacock system and the MlMiC treatment delivery system (Sewickley, PA). Results The anterior-posterior and lateral prostate displacements were minimal, on the order of measurement uncertainty (similar to 1 mm). The standard deviation of superior-inferior displacement was 1.78 mm. Breathing studies showed no organ displacement during normal breathing when the rectal balloon was in place. The rectal toxicity profile was very favorable: 83% (83/100) patients had no rectal complaint, and 11% and 6% had grade 1 and 2 toxicity, respectively. Dose-volume histogram analysis revealed that in all of the patients, no more than 25% of the rectum received 70 Gy or greater. As visualized by film dosimetry, the dose at air-tissue interface was approximately 15% lower than that without an air cavity. The dose built up rapidly so that at 1 and 2 mm, the differential was approximately 8% and 5%, respectively. The dosimetric coverage at the depth of the posterior prostate wall was essentially equal, with or without the air cavity. DISCUSSION The use of a rectal balloon during intensity-modulated radiotherapy significantly reduces prostate motion. Prostate immobilization thus allows a safer and smaller planning target volume margin. It has also helped spare the anterior rectal wall (by its dosimetric effects) and reduced the,rectal volume that received high-dose radiation (by rectal wall distension). All these factors may have further contributed to the decreased rectal toxicity achieved by intensity-modulated radiotherapy, despite dose escalation and higher-than-conventional fraction size.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 51 条
[1]   Prostate target volume variations during a course of radiotherapy [J].
Antolak, JA ;
Rosen, II ;
Childress, CH ;
Zagars, GK ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :661-672
[2]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[3]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[4]   High-precision conformal radiotherapy (HPCRT) of prostate cancer -: A new technique for exact positioning of the prostate at the time of treatment [J].
Bergström, P ;
Löfroth, PO ;
Widmark, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :305-311
[5]   Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms [J].
Boersma, LJ ;
van den Brink, M ;
Bruce, AM ;
Shouman, T ;
Gras, L ;
te Velde, A ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (01) :83-92
[6]   Toward optimal external-beam fractionation for prostate cancer [J].
Brenner, DJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :315-316
[7]  
Brenner DJ, 2002, INT J RADIAT ONCOL, V52, P6
[8]   Fractionation and protraction for radiotherapy of prostate carcinoma [J].
Brenner, DJ ;
Hall, EJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05) :1095-1101
[9]  
Chen ME, 2000, CANCER, V89, P1800, DOI 10.1002/1097-0142(20001015)89:8<1800::AID-CNCR21>3.0.CO
[10]  
2-D