Investigations of a W-Rh permanent modifier for the determination of Pb in blood by electrothermal atomic, absorption spectrometry

被引:43
作者
Zhou, Y
Zanao, RA
Barbosa, F
Parsons, PJ
Krug, FJ
机构
[1] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
[2] New York State Dept Hlth, Wadsworth Ctr Labs & Res, Albany, NY 12201 USA
[3] SUNY Albany, Dept Chem, Albany, NY 12208 USA
[4] SUNY Albany, Sch Publ Hlth, Dept Environm Hlth & Toxicol, Albany, NY 12201 USA
基金
巴西圣保罗研究基金会;
关键词
Pb; blood; electrothermal atomic absorption spectrometry; permanent modifier;
D O I
10.1016/S0584-8547(02)00085-X
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A tungsten-rhodium coating (250 mug W + 200 mug Rh) on the integrated platform of a transversely heated graphite atomizer (THGA) was used as a permanent chemical modifier for the direct determination of lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). Blood samples were diluted 1 + 9 with a diluent consisting of 0.2% v/v HNO3 and 0.5% v/v TritonX-100, and 12 mul of the diluted sample was deposited on the platform. With use of the W-Rh modifier, tube lifetime was improved by a factor of 2-3 when compared with a conventional NH4H2PO4 modifier. With a standard THGA tube, use of the W-Rh permanent modifier allows simple calibration with aqueous standard solutions for blood Pb measurement. However, matrix-matched calibration is still necessary when an end-capped THGA tube is used. The method detection limit (3sigma) based on integrated absorbance measurements is 1.5 mug dl(-1) (0.092 mumol l(-1)) for the standard THGA and 1.0 mug dl(-1) (0.048 mumol l(-1)) for the end-capped tube. Various blood-based certified reference materials and proficiency testing samples, certified for Pb, were analyzed for validation purposes. All results were well within the range considered acceptable. Analysis of human blood samples for blood Pb measurement provided additional validation data against an established blood Pb ETAAS method that uses phosphate modifier. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1291 / 1300
页数:10
相关论文
共 19 条
[1]   Determination of arsenic in sediment and soil slurries by electrothermal atomic absorption spectrometry using W-Rh permanent modifier [J].
Barbosa, F ;
Lima, ÉC ;
Krug, FJ .
ANALYST, 2000, 125 (11) :2079-2083
[2]   The use of a W-Rh permanent modifier for direct determination of bismuth in urine and whole blood by electrothermal atomic absorption spectrometry [J].
Barbosa, F ;
Lima, EC ;
Zanao, RA ;
Krug, FJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) :842-846
[3]   MASS-SPECTRAL INVESTIGATION OF MECHANISMS OF LEAD VAPORIZATION FROM A GRAPHITE SURFACE USED IN ELECTROTHERMAL ATOMIZERS [J].
BASS, DA ;
HOLCOMBE, JA .
ANALYTICAL CHEMISTRY, 1987, 59 (07) :974-980
[4]   Surface and subsurface examination of graphite tubes after electrodeposition of noble metals for electrothermal atomic absorption spectrometry [J].
Bulska, E ;
Thybusch, B ;
Ortner, HM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (04) :363-373
[5]  
Burguera JL, 1997, ATOM SPECTROSC, V18, P109
[6]  
Centers for Disease Control, 1991, PREV LEAD POIS YOUNG
[7]   INVESTIGATION OF HIGH-TEMPERATURE REACTIONS ON GRAPHITE WITH RUTHERFORD BACKSCATTERING SPECTROMETRY - INTERACTION OF CADMIUM, LEAD AND SILVER WITH A PHOSPHATE MODIFIER [J].
ELOI, C ;
ROBERTSON, JD ;
MAJIDI, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :217-222
[8]   Tungsten-rhodium permanent chemical modifier for lead determination in digests of biological materials and sediments by electrothermal atomic absorption spectrometry [J].
Lima, ÉC ;
Barbosa, F ;
Krug, FJ ;
Guaita, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) :1601-1605
[9]   The use of tungsten-rhodium permanent chemical modifier for cadmium determination in decomposed samples of biological materials and sediments by electrothermal atomic absorption spectrometry [J].
Lima, ÉC ;
Barbosa, F ;
Krug, FJ .
ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) :267-274
[10]   Evaluation of tungsten-rhodium coating on an integrated platform as a permanent chemical modifier for cadmium, lead, and selenium determination by electrothermal atomic absorption spectrometry [J].
Lima, EC ;
Krug, FJ ;
Jackson, KW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (13) :1791-1804