A New Method to Measure the Moisture Expansion in Plastic Packaging Materials

被引:5
作者
Ma, Xiaosong [1 ]
Jansen, K. M. B. [1 ]
Ernst, L. J. [1 ]
van Driel, W. D. [1 ]
van der Sluis, O. [1 ]
Zhang, G. Q. [1 ]
机构
[1] Delft Univ Technol, NL-2628 CD Delft, Netherlands
来源
2009 IEEE 59TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE, VOLS 1-4 | 2009年
关键词
MECHANICS;
D O I
10.1109/ECTC.2009.5074174
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Moisture induced failure in plastic encapsulated packages is one most important failure mechanisms in microelectronics. This failure is driven by the mismatch between different material properties, such as CTE, CME (Coefficient of Moisture induced Expansion) caused by moisture absorption in plastic packaging materials. Therefore, it is important to know moisture effects on mechanical properties of plastic packaging materials, especially CME. Moisture induced expansion can be calculated using epsilon = beta . c, here epsilon is the strain, beta is the CME and C is the moisture concentration. Traditionally using the combined TGA (Thermal Gravimetric Analyzer)/TMA (Thermal Mechanical Analyzer) technique, the CME of plastic packaging materials is characterized. TGA is used to measure the weight change and TMA is used to measure the length change. By combining both the TMA and TGA measurements, the CME can be determined. This method is often used in industry and it is observed that the CME value is often over estimated. In order to get precise CME values a high precision DMA (Dynamic Mechanical Analyzer) is used to measure the length change of a sample while a humidity generator is used to regulate the relative humidity. Therefore, temperature and relative humidity are controlled in the DMA chamber and can be used to measure the length change under different relative humidity conditions. CME values measured by the DMA plus humidity method are much lower than that of the TGA/TMA method. In order to find out which method is more reliable, a third experiment was done. A bi-material sample is created to verify our measured CME value. TDM equipment (oven + camera system to detect vertical displacement of the sample) is used to measure the warpage of the bi-material sample. Using our measured CME value, finite element model simulation result shows that the hygromechanical warpage of the model fits well with TDM test result.
引用
收藏
页码:1271 / 1276
页数:6
相关论文
共 8 条
[1]  
Ma XS, 2007, ICEPT: 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONICS PACKAGING TECHNOLOGY, PROCEEDINGS, P380
[2]   Characterization of moisture properties of polymers for IC packaging [J].
Ma, Xiaosong ;
Jansen, K. M. B. ;
Ernst, L. J. ;
van Driel, W. D. ;
van der Sluis, O. ;
Zhang, G. Q. .
MICROELECTRONICS RELIABILITY, 2007, 47 (9-11) :1685-1689
[3]   Characterization of hygroscopic swelling behavior of mold compounds and plastic packages [J].
Stellrecht, E ;
Han, BT ;
Pecht, MG .
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2004, 27 (03) :499-506
[4]   Integrated vapor pressure, hygroswelling, and thermo-mechanical stress modeling of QFN package during reflow with interfacial fracture mechanics analysis [J].
Tee, TY ;
Zhong, ZW .
MICROELECTRONICS RELIABILITY, 2004, 44 (01) :105-114
[5]   The mechanics and impact of hygroscopic swelling of polymeric materials in electronic packaging [J].
Wong, EH ;
Rajoo, R ;
Koh, SW ;
Lim, TB .
JOURNAL OF ELECTRONIC PACKAGING, 2002, 124 (02) :122-126
[6]  
Zhang G.Q, 2006, MECH MICROELECTRONIC, P311
[7]  
ZHOU J, 2005, IEEE 6 INT C THERM M, P112
[8]  
ZHOU J, 2005, INVESTIGATION INNERL