Boron-10 Loaded BC523A Liquid Scintillator for Neutron Detection in the Border Monitoring

被引:33
作者
Swiderski, L. [1 ]
Moszynski, M. [1 ]
Wolski, D. [1 ]
Batsch, T. [1 ]
Nassalski, A. [1 ]
Syntfeld-Kazuch, A. [1 ]
Szczesniak, T. [1 ]
Kniest, F. [2 ]
Kusner, M. R. [3 ]
Pausch, G. [4 ]
Stein, J. [4 ]
Klamra, W. [5 ]
机构
[1] Soltan Inst Nucl Studies, PL-05400 Otwock, Poland
[2] St Gobain Crystals, Holland Off, NL-3760 DB Soest, Netherlands
[3] St Gobain Crystals, Newbury, TX 77005 USA
[4] ICx Radiat GmbH, D-42651 Solingen, Germany
[5] Royal Inst Technol, S-10691 Stockholm, Sweden
关键词
Boron-10; liquid scintillators; neutron detection; zero-crossing method;
D O I
10.1109/TNS.2008.2006172
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A BC523A liquid scintillator loaded with boron-10 was tested as a detector for both fast and thermal neutrons. A pulse shape discrimination (PSD) method based on a zero-crossing principle was applied to distinguish between neutron and gamma radiation. High quantum efficiency Photonis XP5500B photomultiplier was used to enhance light detection from the scintillator. This allowed a good registration of the energy spectrum of neutron capture events on boron-10, corresponding to about 60 keV gamma-rays. The applied PSD method proved to be useful for n/gamma discrimination. A good resolving power of the method was achieved even without gating on neutron capture events. A comparison with a standard BC501A liquid scintillator was done to evaluate thermal neutrons detection efficiency in BC523A.
引用
收藏
页码:3710 / 3716
页数:7
相关论文
共 18 条
[1]   Development of a handheld device for simultaneous monitoring of fast neutrons and gamma rays [J].
Aryaeinejad, R ;
Reber, EL ;
Spencer, DF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) :1909-1913
[2]   WALL EFFECT IN BF3 COUNTERS [J].
CERVELLATI, R ;
KAZIMIERSKI, A .
NUCLEAR INSTRUMENTS & METHODS, 1968, 60 (02) :173-+
[3]   INTEGRAL TEST OF A B-10 LOADED LIQUID SCINTILLATOR FOR NEUTRON DETECTION [J].
CHOU, HP ;
HORNG, CY .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 328 (03) :522-525
[4]   Identification of shielded neutron sources with the liquid scintillator BC-501A using a digital pulse shape discrimination method [J].
Flaska, M. ;
Pozzi, S. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 577 (03) :654-663
[5]   Digital pulse-shape algorithms for scintillation-based neutron detectors [J].
Jastaniah, SD ;
Sellin, PJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) :1824-1828
[6]  
Knoll G. F., 1999, RAD DETECTION MEASUR, P679
[7]  
KNOLL GF, 1999, RAD DETECTION MEASUR, P558
[8]   Development of a gadolinium-loaded liquid scintillator for solar neutrino detection and neutron measurements [J].
Lightfoot, PK ;
Kudryavtsev, VA ;
Spooner, NJC ;
Liubarsky, I ;
Luscher, R ;
Smith, NJT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (03) :439-446
[9]   LOW VOLTAGE HE3-FILLED PROPORTIONAL COUNTER FOR EFFICIENT DETECTION OF THERMAL AND EPITHERMAL NEUTRONS [J].
MILLS, WR ;
CALDWELL, RL ;
MORGAN, IL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (08) :866-&
[10]   STUDY OF N-GAMMA DISCRIMINATION WITH NE213 AND BC501A LIQUID SCINTILLATORS OF DIFFERENT SIZE [J].
MOSZYNSKI, M ;
COSTA, GJ ;
GUILLAUME, G ;
HEUSCH, B ;
HUCK, A ;
MOUATASSIM, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) :226-234