Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes

被引:97
作者
Otto, KJ
Johnson, MD
Kipke, DR
机构
[1] Univ Michigan, Kresge Hearing Res Inst, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
brain-machine interface; chronic recording; iridium; neuroprosthesis; silicon;
D O I
10.1109/TBME.2005.862530
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current neuroprosthetic systems based on electrophysiological recording have an extended, yet finite working lifetime. Some posited lifetime-extension solutions involve improving device biocompatibility or suppressing host immune responses. Our objective was to test an alternative solution comprised of applying a voltage pulse to a microelectrode site, herein termed "rejuvenation:'' Previously, investigators have reported preliminary electrophysiological results by utilizing a similar voltage pulse. In this study we sought to further explore this phenomenon via two methods: 1) electrophysiology; 2) an equivalent circuit model applied to impedance spectroscopy data. The experiments were conducted via chronically implanted silicon-substrate iridium microelectrode arrays in the rat cortex. Rejuvenation voltages resulted in increased unit recording signal-to-noise ratios (10% +/- 2%), with a maximal increase of 195% from 3.74 to 11.02. Rejuvenation also reduced the electrode site impedances at 1 kHz (67% +/- 2%). Neither the impedance nor recording properties of the electrodes changed on neighboring microelectrode sites that were not rejuvenated. In the equivalent circuit model, we found a transient increase in conductivity, the majority of which corresponded to a decrease in the tissue resistance component (44% +/- 7%). These findings suggest that rejuvenation may be an intervention strategy to prolong the functional lifetime of chronically implanted microelectrodes.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 36 条
[1]   Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy [J].
Buitenweg, JR ;
Rutten, WLC ;
Willems, WPA ;
van Nieuwkasteele, JW .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) :630-637
[2]  
Cui XY, 2001, J BIOMED MATER RES, V56, P261, DOI 10.1002/1097-4636(200108)56:2<261::AID-JBM1094>3.0.CO
[3]  
2-I
[4]   FACTORS INFLUENCING THE BIOCOMPATIBILITY OF INSERTABLE SILICON MICROSHAFTS IN CEREBRAL-CORTEX [J].
EDELL, DJ ;
TOI, VV ;
MCNEIL, VM ;
CLARK, LD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :635-643
[5]  
HEETDERKS WJ, 1997, COMMUNICATION
[6]   Direct control of a computer from the human central nervous system [J].
Kennedy, PR ;
Bakay, RAE ;
Moore, MM ;
Adams, K ;
Goldwaithe, J .
IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (02) :198-202
[7]   Chronic response of adult rat brain tissue to implants anchored to the skull [J].
Kim, YT ;
Hitchcock, RW ;
Bridge, MJ ;
Tresco, PA .
BIOMATERIALS, 2004, 25 (12) :2229-2237
[8]   Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex [J].
Kipke, DR ;
Vetter, RJ ;
Williams, JC ;
Hetke, JF .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (02) :151-155
[9]  
Liu X, 1999, IEEE Trans Rehabil Eng, V7, P315, DOI 10.1109/86.788468
[10]   The Utah Intracortical Electrode Array: A recording structure for potential brain-computer interfaces [J].
Maynard, EM ;
Nordhausen, CT ;
Normann, RA .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (03) :228-239