Femur Positioning in Navigated Total Knee Arthroplasty

被引:8
|
作者
Pfitzner, Tilman [1 ]
Roehner, Eric [1 ]
Preininger, Bernd [1 ]
Perka, Carsten [1 ]
Matziolis, Georg [1 ]
机构
[1] Charite, Dept Orthopaed, Ctr Musculoskeletal Surg, D-10117 Berlin, Germany
关键词
COMPUTER-ASSISTED SURGERY; CONVENTIONAL TECHNIQUE; COMPONENT ALIGNMENT; TKA; METAANALYSIS; REPLACEMENT; PRECISE;
D O I
10.3928/01477447-20120919-57
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Navigated total knee arthroplasty (TKA) results in better restoration of neutral mechanical axis than does the conventional technique. Nevertheless, coronal malalignment has not been eliminated. It is yet unknown whether errors in implant positioning occur more on the femoral side, more on the tibial side, or equally on both sides. The hypothesis of this study was that a predominance of coronal component malalignment exists on the tibial side in navigated tibia-first TKA. Fifty-seven consecutive navigated (OrthoPilot; B. Braun Aesculap, Tuttlingen, Germany) TKAs were included in this retrospective study. Pre- and postoperative digital whole-leg standing radiographs were analyzed. Coronal alignment was measured for the whole leg pre- and postoperatively. Lateral distal femur angle and medial proximal tibia angle were analyzed on the preoperative radiographs. On the postoperative radiographs, coronal alignment of the femoral and tibial components were measured separately in reference to the tibial and femoral mechanical axis. The coronal alignment improved from 8.2 degrees +/- 3.7 degrees preoperatively to 1.1 degrees +/- 1.2 degrees postoperatively, with 5 (8%) outliers outside the 3 degrees window. The femoral component was malaligned (0.6 degrees +/- 0.6 degrees), whereas the tibial component showed a significantly higher deviation from the mechanical axis of 1.0 degrees +/- 1.1 degrees (P=.009). The femoral component was positioned more precisely than the tibial component. The latter influences gap management in the tibia-first technique and may thereby have a relevant effect on joint stability. Accuracy of the surgical technique and differences in the mathematical algorithm for the determination of landmarks are possible reasons for the difference in precision between the femoral and tibial component positioning.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [1] Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty
    Ko, Jae Han
    Han, Chang Dong
    Shin, Kyoo Ho
    Nguku, Levis
    Yang, Ick Hwan
    Lee, Woo Suk
    Kim, Kwang Il
    Park, Kwan Kyu
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2476 - 2482
  • [2] Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty
    Jae Han Ko
    Chang Dong Han
    Kyoo Ho Shin
    Levis Nguku
    Ick Hwan Yang
    Woo Suk Lee
    Kwang Il Kim
    Kwan Kyu Park
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2476 - 2482
  • [3] Anthropometric measurements of the femur change with component positioning in total knee arthroplasty
    Thienpont, Emnianuel
    Bernardoni, Massimiliano
    Goldberg, Tyler
    KNEE, 2016, 23 (05): : 796 - 800
  • [4] Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur
    Lin, Sung-Yen
    Chen, Chung-Hwan
    Huang, Peng-Ju
    Fu, Yin-Chih
    Huang, Hsuan-Ti
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2014, 30 (08): : 415 - 421
  • [5] Experiences with computer navigated total knee arthroplasty
    Zoltán Bejek
    László Sólyom
    Miklós Szendrõi
    International Orthopaedics, 2007, 31 : 617 - 622
  • [6] Experiences with computer navigated total knee arthroplasty
    Bejek, Zoltan
    Solyom, Laszlo
    Szendroi, Miklos
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (05) : 617 - 622
  • [7] Navigated versus Conventional Total Knee Arthroplasty
    Moskal, Joseph T.
    Capps, Susan G.
    Mann, John W.
    Scanelli, John A.
    JOURNAL OF KNEE SURGERY, 2014, 27 (03) : 235 - 248
  • [8] Process optimization in navigated total knee arthroplasty
    Walde, TA
    Burgdorf, D
    Walde, HJ
    ORTHOPEDICS, 2005, 28 (10) : S1255 - S1258
  • [9] Computer Navigated Versus Conventional Total Knee Arthroplasty
    Tolk, Jaap J.
    Koot, Henk W. J.
    Janssen, Rob P. A.
    JOURNAL OF KNEE SURGERY, 2012, 25 (04) : 347 - 352
  • [10] Navigated total knee arthroplasty: is it error-free?
    Kerk Hsiang Zackary Chua
    Yongsheng Chen
    Krishna Lingaraj
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 643 - 649