Truncation artifact on PET/CT: Impact on measurements of activity concentration and assessment of a correction algorithm

被引:37
作者
Mawlawi, O
Erasmus, JJ
Pan, TS
Cody, DD
Campbell, R
Lonn, AH
Kohlmyer, S
Macapinlac, HA
Podoloff, DA
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Imaging, Houston, TX 77030 USA
[3] GE Healthcare, Wukesha, WI USA
关键词
attenuation correction; nuclear medicine; oncologic imaging; PET/CT; truncation artifact;
D O I
10.2214/AJR.05.0255
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Discrepancy between fields of view (FOVs) in a PET/CT scanner causes a truncation artifact when imaging extends beyond the CT FOV. The purposes of this study were to evaluate the impact of this artifact on measurements of F-18-FDG activity concentrations and to assess a truncation correction algorithm. MATERIALS AND METHODS. Two phantoms and five patients were used in this study. In the first phantom, three inserts (water, air, bone equivalent) were placed in a water-filled cylinder containing F-18-FDG. In the second phantom study, a chest phantom and a 2-L bottle fitted with a bone insert were used to simulate a patient's torso and arm. Both phantoms were imaged while positioned centrally (baseline) and at the edge of the CT FOV to induce truncation. PET images were reconstructed using attenuation maps from truncated and truncation-corrected CT images. Regions of interest (ROIs) drawn on the inserts, simulated arm, and background water of the baseline truncated and truncation-corrected PET images were compared. In addition, extremity malignancies of five patients truncated on CT images were reconstructed with and without correction and the maximum standard uptake values (SUVs) of the malignancies were compared. RESULTS. Truncation artifact manifests as a rim of high activity concentration at the edge of the truncated CT image with an adjacent low-concentration region peripherally. The correction algorithm minimizes these effects. Phantom studies showed a maximum variation of -5.4% in the truncation -corrected background water image compared with the baseline image. Activity concentration in the water insert was 6.3% higher while that of air and bone inserts was similar to baseline. Extremity malignancies showed a consistent increase in the maximum SUV after truncation correction. CONCLUSION. Truncation affects measurements of F-18-FDG activity concentrations in PET/CT. A truncation-correction algorithm corrects truncation artifacts with small residual error.
引用
收藏
页码:1458 / 1467
页数:10
相关论文
共 23 条
[1]   Non-small cell lung cancer: Dual-modality PET/CT in preoperative staging [J].
Antoch, G ;
Stattaus, J ;
Nemat, AT ;
Marnitz, S ;
Beyer, T ;
Kuehl, H ;
Bockisch, A ;
Debatin, JF ;
Freudenberg, LS .
RADIOLOGY, 2003, 229 (02) :526-533
[2]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[3]   Fluorine-18 deoxyglucose positron emission tomography for the detection of bone metastases in patients with non-small cell lung cancer [J].
Bury, T ;
Barreto, A ;
Daenen, F ;
Barthelemy, N ;
Ghaye, B ;
Rigo, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (09) :1244-1247
[4]  
CARNEY J, 2003, CLIN MOL ANATOMIC IM, P51
[5]   Positron emission tomography scanning with 2-fluoro-2-deoxy-D-glucose as a predictor of response of neoadjuvant treatment for non-small cell carcinoma [J].
Cerfolio, RJ ;
Ojha, B ;
Mukherjee, S ;
Pask, AH ;
Bass, CS ;
Katholi, CR .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (04) :938-944
[6]  
ERASMUS JJ, 2005, CARDIOPULMONARY IMAG, P287
[7]  
Goerres GW, 2004, J NUCL MED, V45, p66S
[8]   A novel reconstruction algorithm to extend the CT scan field-of-view [J].
Hsieh, J ;
Chao, E ;
Thibault, J ;
Grekowicz, B ;
Horst, A ;
McOlash, S ;
Myers, TJ .
MEDICAL PHYSICS, 2004, 31 (09) :2385-2391
[9]   Attenuation correction for a combined 3D PET/CT scanner [J].
Kinahan, PE ;
Townsend, DW ;
Beyer, T ;
Sashin, D .
MEDICAL PHYSICS, 1998, 25 (10) :2046-2053
[10]  
Kluetz P G., 2000, Clin Positron Imaging, V3, P223, DOI 10.1016/S1095-0397(01)00055-3